Alpha-Stim Therapy For Animals Veterinary Supplement to the Alpha-Stim M Owner s Manual

Similar documents
FREQUENTLY ASKED QUESTIONS Pet Owners

PetSpy Advanced Dog Training System, Model M86N

Smart bark control collar BC-2. User manual

Knee Brace Fit and Care Instructions

DREXEL UNIVERSITY COLLEGE OF MEDICINE ANIMAL CARE AND USE COMMITTEE POLICY FOR PREOPERATIVE AND POSTOPERATIVE CARE FOR NON-RODENT MAMMALS

K9K-914 Anti Bark Collar User's Manual. Introduction:

Express Train Electronic Radio Dog Training Collar

CANINE REHABILITATION IN THE GENERAL VETERINARY PRACTICE Stacy Reeder, DVM Animal Hospital of Waynesboro

INNOTEK. Spray Bark Control. Operating Guide. Please read this entire guide before beginning.

SUPER TRAINER EZT SERIES

prepare perform recover Product Catalog

V EN

7300 SPT 7302 SPT 7800 SPT 7802 D.T. SYSTEMS, INC.

Knee Brace Fit and Care Instructions

Indication for laser acupuncture, body and ear acupuncture treatment

NoBark 6. Operating Guide. Please read this entire guide before beginning

PetSpy Premium Dog Training Collar, Models M919-1/M919-2

How it works. To name only a few, all of which can be treated using massage therapy.

APPLICATION FOR LIVE ANIMAL USE IN TEACHING AT FAULKNER STATE COMMUNITY COLLEGE

Animal Studies Committee Policy Rodent Survival Surgery

Ultra Min No-Bark Training Collar Ultra Small Ultra Powerful Ultra Control

Casey Kerry Blue Terriers

Introduction. A quick note about how GentleSteps was developed

Mobility Issues and Arthritis

SAMPLE NOT FOR SALE 8 Weeks and Older and 9 lbs. and Under 1 Pack x 20 x 145

USA Product Label PARASTAR PLUS (45-88 LBS.) Novartis. (fipronil/cyphenothrin) 3 EASY-TO-USE APPLICATIONS. For dogs lbs.

FOUR STAGES OF HEALING & BEST USE OF SILVER WHINNYS

MEDICAL CENTER POLICY NO.

Don t let arthritis slow down your dog!

USA Product Label

Unshakeable confidence

Lioness Guidebook: Open Me to Get Started!

UPEI / AVC Guidelines for Categories of Invasiveness and Rest Periods for Teaching Animals

APPLICATION FOR LIVE ANIMAL USE IN TEACHING AT FAULKNER STATE COMMUNITY COLLEGE

SGV POLICY ON THE TRANSPORT OF INJURED GREYHOUNDS

Backcountry First Aid Prevention, Triage and

Dairy Cattle Assessment protocol

by Dogtra Portable Remote Controlled Dog Training Collars Owner s Manual

By Dogtra Remote Controlled Dog Training Collars. Owner's Manual. Please read this manual thoroughly before operating the Dogtra ARC training collar.

KNEE BRACE CASTING INSTRUCTIONS

The Community Pharmacy and Veterinary Medicines. The Opportunities

Prescription Label. Patient Name: Species: Drug Name & Strength: Directions (amount to give how often & for how long):

ANNEX III LABELLING AND PACKAGE LEAFLET

Remote Trainer. by Dogtra Portable Remote Controlled Dog Training Collars. Owner s Manual

Kirkland Signature Minoxidil Topical Solution USP, 5% Drug Facts

Lameness Exams. Evaluating the Lame Horse

For every purpose of dog, there are specific builds that give superior performance.

By Dogtra Remote Controlled Dog Training Collars. Owner's Manual. Please read this manual thoroughly before operating the Dogtra 280C training collar.

EC-AH-011v1 January 2018 Page 1 of 5. Standard Operating Procedure Equine Center Clemson University

Starts working through contact

Revisions to the Obedience Regulations Effective May 1, 2018

PLEASE POST. EMS Providers are to ensure that all EMS personnel receive this information.

ANNEX I SUMMARY OF PRODUCT CHARACTERISTICS 1/18

Clumber Spaniel Club Health Survey 2014 Summary of Results

SINGLE ANNUAL IMPLANT

TABLE OF CONTENTS. Chronic...60 Neck Pain or Injury Upper Cervical Acute...62

A UNIQUE HARNESS SYSTEM WORKS WITH YOUR DOG S REFLEX

Pet-Temp PT-300 Ear Thermometer Frequently Asked Questions

INDEX. Note: Page numbers of article titles are in boldface type. LAMENESS

ANNEX I SUMMARY OF PRODUCT CHARACTERISTICS. Medicinal product no longer authorised

LABELLING AND PACKAGE LEAFLET

INTRODUCTION PRODUCT FEATURES. Congratulations on your purchase of the Yapper Stopper Model YS500.

Owner: Address: City: ZIP: Telephone: Cell: Pet's Name: Sex: M F Spayed/Neutered. Breed: DOB or age: Wt: Description (color, markings) :

Day 90 Labelling, PL LABELLING AND PACKAGE LEAFLET

The femoral head (the ball in the ball and socket joint) is outlined in

Company: Richter Pharma AG MUTUAL RECOGNITION PROCEDURE PUBLICLY AVAILABLE ASSESSMENT REPORT FOR A VETERINARY MEDICINAL PRODUCT

Owner s Manual. by Dogtra Portable Remote Controlled Dog Training Collars

acupressure for joint conditions

Lameness Evaluation How to Spot It First Aid for Common Conditions When to Call the Vet. Ocean State Equine Associates

Hip Dysplasia. So What is Hip Dysplasia? If this Disease Starts in Puppy hood, Why are Most Affected Dogs Elderly?

EMERGENCIES When to Call the Vet And What to Do Until They Arrive

THE HAPPY HIP PROGRAM

E-Collar Technologies, Inc. 400/402 Owner's Manual Happiness is a Well Behaved Dog

IN THE DAILY LIFE of a veterinarian or

SUMMARY OF PRODUCT CHARACTERISTICS

Regional and Local Anesthesia of the Wrist and Hand Aided by a Forearm Sterile Elastic Exsanguination Tourniquet - A Review

APPLICATION FOR LIVE ANIMAL USE IN TEACHING AT COASTAL ALABAMA COMMUNITY COLLEGE

XL³ 800 IP 55metal distribution cabinets, freestanding enclosures and cable compartments

Getting Started. Device Overviews. Setting Up the Pro 550 System Before you can use the Pro 550 system, you must set up the devices.

DOWNLOAD OR READ : MANUAL OF OPERATIVE VETERINARY SURGERY PDF EBOOK EPUB MOBI

THE CHARACTERISTICS OF LAMENESS IN DAIRY COWS

SOP #: Page: 1 of 6 Rodent Analgesia

ONE collar. flea larvae. REPELS and kills fleas. REPELS and kills ticks. cat convenient, easy-to-apply collar. 8month protection

XL³ 400 class II insulated distribution cabinets and cable compartments

Operating Guide. PBC Rechargeable Bark Control Collar. Please read this entire guide before beginning.

IEEE Std 592 Test Program using Current Cable Accessories and Installation Practices

Blood Collection Healthcare

EXCEDE Sterile Suspension

Product Manual. PBC Bark Collar. Please read this entire Product Manual before beginning.

PROTOCOL FOR THE HUMANE CARE AND USE OF LIVE VERTEBRATE ANIMALS

Euthanasia in poultry: Why, when and how. Dr. Jenny Fricke Dr. Karen Schwean-Lardner

Flea & Tick Spray CAUTION. Breaks flea life cycle for up to 2 months KILLS: KEEP OUT OF REACH OF CHILDREN. fleas. ticks. flea eggs.

2/5/2016. Military Tourniquet PFN:SOMTRL0B. Terminal Learning Objective. Reason. Hours: 0.5

Wounds and skin injuries

400 Yard Trainer GDT Product Manual

OWNER S MANUAL For extra small-size wheelchair (0-15 lbs)

Mouse Formulary. The maximum recommended volume of a drug given depends on the route of administration (Formulary for Laboratory Animals, 3 rd ed.

Author of PGD: Adrian MacKenzie, Lead Pharmacist, Community Pharmacy.

Use to regrow hair on the top of the scalp (vertex only, see pictures on side of this carton)

LABELLING AND PACKAGE LEAFLET A. LABELLING

Transcription:

Alpha-Stim Therapy For Animals Veterinary Supplement to the Alpha-Stim M Owner s Manual LET NOTHING STOP THEM.

Acute Pain Microcurrent Electrical Therapy Sprains, Trauma, Surgery, Disc Chronic Pain Arthritis, Muscles, Back Headaches Edema Healing Post surgical Fractures Wounds and Granulomas Neurological Dysfunction Applications in Veterinary Practice Anxiety Cranial Electrotherapy Stimulation Separation Anxiety Syndrome Nervousness Fear of storms, fireworks Obsessive Compulsive Disorder Cognitive Dysfunction Sympathetic dominant state Depression Upper Motor Neuron Dysfunction Pain Treating Animals With Alpha-Stim Assess the Pain Diagnosis is helpful, but not everything. What position(s) exacerbate them? Note any obvious signs or any related problems. Where are all pain/problems located? How bad are they on a 1-10 scale now? Note all scars and old injuries as these might need to be treated too. Prepare the Device Frequency When using the Alpha-Stim, check the to confirm that it is set at 0.5 Hz. Current Current is marked in 100 microamperage increments starting with the number 1 on the LCD. Always begin therapy with it set at zero. Gradually increase to the appropriate level over 20 seconds. Duration The timer button allows for time to be set from ten seconds to infinity. Treat as directed starting daily then reducing to every other day and then once or twice a week as needed. Wean patients off slowly if possible by increasing the intervals between treatments. Patient Monitoring You may stop treatment when the pain or specific symptom is gone or greatly reduced. Use behavioral changes, pain score, lameness evaluation and range of motion to assess improvement in animals. CES might relax or cause dizziness that could not be easily detected in animals. Refrain from riding a horse or racing a dog immediately following application. Allow 30-60 minute rest period before performing.

Basic 5 - Step Protocol When Using Probes & CES General Treatment Pattern - Alpha-Stim Treatment Probes Frequency (0.5 100 Hz) 0.5 Hz, 100 Hz for the first set only if it is a chronic condition (100 Hz will produce faster results, but treatment must then be readministered at 0.5 Hz for lasting results). Current (600 microamperes is 6 on the LCD) Standard setting is 600 µa. This works in dogs and most cats, but often will not be tolerated by a horse. Always reduce to a comfortable level. Do not force a specific setting, higher current does not produce better results. Duration Generally 10-20 seconds per contact site. Note: Fur on animals will readily wick the Alpha Conducting Solution so you will need to wet the pads every 1-2 minutes of treatment. 1. First treat in a big X beyond the area(s) of pain. 10-20 seconds for each side of the X When possible, treat to include area outside of the adjacent joints. For back pain, treat from the neck to the pelvis. For extremity pain, treat from the most proximal to the most distal point in a lateral/medial or anterior/ posterior direction. 2. Then treat through the areas in three dimensions, like a star (e.g., 2 obliques, A - P, M - L). 10 seconds each. Multiple directions or planes through the affected area. 1 to 3 treatment sets. 3. Treat the opposite side even if it is asymptomatic. 1 large X and 1 star through opposite same joint (this would not apply to spinal treatments). Reevaluate pain at completion of a set. 4. Always connect both sides (most important step). Connect the two sides at the corresponding anatomy: proximal lateral, proximal medial, distal lateral and distal medial of the pathological site. Consider anatomy (e.g., encompass entire muscle) and treat scars and old injuries as necessary as they might function as resistors in bioelectric circuitry. To get under the fur, work the probe down to the skin with a circular motion and press fairly hard. 5. Finish with CES. Reevaluate pain at completion of treatment. Note: Remember to reapply Alpha Conducting Solution to the felt pads on the probes every minute or two of therapy and work the probe down to a firm contact with the skin using a circular motion.

General Treatment Pattern - Cranial Electrotherapy Stimulation (CES) Frequency (0.5 Hz) Current (100-600 microamperes is 1 6 on the LCD) Cats: 50-100 µa Dogs: 200-300 µa Horses: 50-150 µa Duration Initially 20 minutes then adjust as the animal responds over time. Once a day for 2 weeks then every other day 2 more weeks. With obsessive compulsive disorder or separation anxiety syndrome, and cribbing or anxiety related stress in horses, start at 1 hour per treatment. For animals with very thick fur, it might be advantageous to shave a small spot on the outside surface of the external ear. Clean skin surface inside and out with alcohol. Use a generous amount of Alpha Conducting Solution as the fur will wick the moisture away. Place the clips at the lower side of the ears for most conditions. General Treatment Pattern- AS-Trodes Frequency (0.5 Hz) Current (100-600 microamperes is 1-6 on the LCD) Pain treatment at 400-600 µa, younger animals may need the current reduced even further. Healing treatment at 100 µa. Duration: Minimum 1 hour, can run 24/7. Area of placement MUST be shaved. Clean skin surface with alcohol and dry. Place AS-Trodes in diagonal across the affected area(s) with enough distance to cover all muscles and tissue involved and to direct the current through the primary site. Too close together or positioned incorrectly could allow the current to run just beneath the skin surface and miss the pathology. Prevent the AS-Trodes from touching fur as fur will stick to the surface and reduce the amount of usages. Note: If the AS-Trodes become dry, wet with a few drops of Alpha Conducting Solution, place on protective backing and store overnight.

Alpha-Stim Cranial Electrotherapy Stimulation Dog Clean ears with alcohol. Apply conduction solution to pads. Connect wires to the device and the clips to the ears. Set to 0.5 Hz and 200-300 µa intensity. Adjust to comfort. Run for 20 minutes or at least 3 minutes past relaxation. 60 minutes initially for obsessive compulsive disorder or separation anxiety syndrome. Horse CES clips will work on most horses. Use a cotton ball to clean the ear site with alcohol. Attach the moist clips to the ear and wait a minute for the horse to adapt before turning on the unit. It may take a few times of replacing the clips but be patient. Soon the horse will accept them and stop shaking them loose. Set the device to 0.5 Hz and 50 µa. After a few treatments you might be able to gradually increase up to 150 µa. Standard treatments start at 20 minutes. For severe conditions, 1 hour may be required. For horses that are ear sensitive, the AS-Trodes are an option but shaving the area may be required. Clean the skin with alcohol then dry the area. Apply the AS-Trodes to each side of the head at either the temporal area just in front of the ear or midway between the ear and eye. Set the Alpha-Stim to 0.5 Hz and 100 µa current. After a few treatments you might be able to gradually increase to a current level of 200 µa. Guinea Pigs CES can be delivered to guinea pigs in the same manner as other species. They are sensitive animals so keep the current to 200 µa or less. Cats Cats can be treated in similar patterns as described for the dog when using the probes. For CES, reduce the current. Start at 50 µa, then you can try gradually to increase the current up to a setting of 150 µa. Rabbits Rabbits consume high doses of anesthetics and analgesics. They respond well to incorporating CES as part of a preanesthetic protocol. Start CES 5 minutes after sedation and set at 0.5 Hz and 400 µa.

Special Considerations Example of a Treatment: Arthritis or Pain in the Hip Big X to encompass from an anterior point at lumbosacral joint (probe A) to beyond the hock on posterior point (probe B). Treat 20 seconds. Then finish the Big X by moving Probe B to the ischium and Probe A to the anterior side of the paw. Treat 20 seconds. Multiple Stars (each 10 seconds) are then directed around and through the coxofemoral joint. Estimate treatment time here 2 minutes. Opposite Leg: Repeat the Big X and 2 Stars. If it is also symptomatic treat in a like manner as above. Connect to the Diagonal: Apply probe A to the affected rear leg and probe B to the diagonal front leg, treat 30 seconds. Connect Both Sides: Apply probe A and B directly horizontal lateral-lateral and medial-medial twice each starting outside at the gluteals, inside groin, inside stifle and outside hock. Treating both legs simultaneously per point 10 seconds each for a total of 40 seconds. Remember to rewet the pads every minute or so of treatment and work the probe down to the skin in a circular motion. CES: Finish with CES for 20 minutes. Large or Slow Healing Wounds AS-Trodes can be used in a diagonal application across an open wound. This will manage the pain and accelerate the healing of the wound. The area under the AS-Trodes must be kept shaved. Replace pads as necessary and clean the area with alcohol before reapplying. Duct tape or other bandage material may be used over them if necessary to maintain the positioning. Run as many hours per day as possible. 24/7 is great for severe and deep wounds. 3-8-2004 One month post wound, at initiation of MET therapy. 3-8-2004 At initiation of MET therapy to show proportion of wound. Note also the lack of skin available to cover wound site. 3-18-04 Ten days of MET showing substantial healing and a clean wound. 3-30-04 After three weeks of MET, treatment was completed. 7-1-2004 The horse was returned to training.

Wounds and Lick Granulomas Probes can also be used and applied diagonally across the wound with 10 second treatments, encircling the area 3 times. Treat 2 times a day for 2 weeks, then continue once a day until healing is complete. Rewet pads approximately every minute of treatment time. Scars There are two options for treating scars: 1. AS-Trodes placed at each end of the scar. 10 minutes per day for 4 days. Current level as high as comfortably tolerable. 2. Probes placed at each end of the scar. 3 minutes per day for 4 days. Then repeat in 1 month. Standard probe settings. Chronic Conditions Treat the first 2 to 3 minutes at 100 Hz, then 0.5 Hz. Make sure to run both peripheral MET and central CES modalities. Remember that a chronic condition may reverse back through a brief acute phase. Symptoms consistent with an acute relapse may appear. Continue treating and that should dissipate over time. Treating Elbow, Carpus, Stifle, Hock **These joints need to have the final star be applied directly across the joint while in a flexed position. This is an important step! Big X Stars: Diagonal, direct AP, direct ML, and lastly across the flexed joint. Other side (only need to flex if it is also symptomatic). Connect both sides including the diagonals. CES: Finish with CES for 20 minutes. 10-Step Prophylactic Care for the Performance Animal 1. Big X across the neck. 2. Big X across the spine. 3. Big X across each front leg. 4. Big X across each rear leg. 5. Connect the two sides. 6. Two rear legs. 7. Two front legs. 8. Diagonals. 9. Neck and spine. 10. Finish with 10 minutes of CES.

Electrical Alpha-Stim M Technical Specifications Batteries 2 AA 1.5 volt (included) Timer 10 second Smart Probe activated by skin contact, 10, 20, 40, and 60 minute count down timers to auto-off, and continuous time elapsed timer. Current 0 to 600 microamperes (µa) Frequency 0.5, 1.5, or 100 Hz (pulses per second) combined with a constant 0.4 Hz. The average pulse repetition rate is 0.8 Hz at the most widely used setting of 0.5 Hz. Pulse Widths Varying between 0.25, 0.5, 0.75, and 1 second at 0.5 Hz. Charge At 600 µa and 0.5 Hz the charge per pulse varies between 150, 300, 450 and 600 microcoulombs (µc). Every 10 seconds the total charge is 1.5 millicoulombs (mc) in each direction. Waveform The impedance range within which the waveform parameters remain valid are from 100 Ω to 10 K Ω. The waveform is composed of bipolar asymmetric rectangular waves at a 50% duty cycle repeating periodically. At 0.5 Hz it repeats at 10 second intervals. The wave form is balanced to achieve 0 net current in either direction. The Alpha-Stim M comes complete and ready to use with 1 set of Earclip electrodes, 1 15-ml bottle of Alpha Conducting Solution (250 ml refill bottles available), 2 sets of lead wires for 4 electrodes, 2 Smart Probes, 4 silver AS-Trode brand single person multiple use self-adhesive electrodes (good for approximately 2 weeks to 1 month of use), 100 Probe Electrode Pads (PEPS ), 256 Earclip Electrode Pads (EEPS), Illustrated Owner s Manual, Lanyard, Storage Case, and 2 AA Batteries. Five Year Warranty: Each Alpha-Stim M is warranted to be free from defects in materials and workmanship under normal use for a period of five years except for replacement of batteries and accessories. See Owner s Manual for complete details. Care of Equipment Alpha-Stim devices are durable but it is important to take care of your equipment. Treat them as a medical device. Our patients will not tell us if they don t feel anything so we need to take these simple steps to make certain they are getting the therapy we think we are delivering! If you are using them daily, check ear clips once a week. These can be tested by holding them lateral to your eyes. The microcurrent will be picked up by your eyes and you will see some flashing lights. This means the system is working. Pinch the clips to release them from the ears rather than pulling them by the connecting wire. Do not store by wrapping the wires around the device. The wire inside is very fine and could break after repeated use in such a manner. Keep the device clean by using alcohol on the outer parts but be careful to not get any inside. When changing the pads, new ones will adhere better if you clean the ear clips with alcohol and dry them prior to application of a new pad. Do this at the end of a treatment so that the pads have ample time to set before the Alpha Conducting Solution is applied. Use only Alpha Conducting Solution. It is specially designed to allow smooth conduction of the microcurrent across the skin barriers. Manufactured and marketed by: Electromedical Products International, Inc. 2201 Garrett Morris Parkway Mineral Wells,Texas 76067-9034 USA Tel: 1.800.367.7246 in the USA or 940.328.0788 Fax: 940.328.0888 / Email: info@epii.com www.alpha-stim.com Authorized Representative for the European Union: MediMark Europe 11, rue Émile Zola BP 2332/38033 Grenoble Cedex2 France Tél: +33 (0)4 76 86 43 22/Fax: +33 (0)4 76 17 19 82 E-Mail: info@medimark-europe.com Prescription Information CE Conformity Statement for Europe The Alpha-Stim M and AID are Class IIa, Type BF medical devices. They have been independently tested by Underwriter Laboratories (UL) to provide assurance of conformity to applicable standards for medical equipment safety and electromagnetic compliance. Caution Statement for United States Federal law (USA only) restricts this device to sale by or on the order of a licensed healthcare practitioner. Outside of the USA it is available world wide without a prescription but consultation with a qualified healthcare practitioner is recommended. Indications Alpha-Stim M is an effective treatment with broad applications for a variety of syndromes involving pain, and both the M and AID are used for the management of anxiety, insomnia and depression, or for the short term relief of symptoms associated with these indications. In many cases, Alpha-Stim is the sole therapeutic method required. Effective results in pain management have been achieved during and/or subsequent to stimulation over effected body parts, adjacent areas, and areas distant from those in pain. As with any therapeutic intervention, not all animals will respond to Alpha-Stim. The degree of efficacy will vary with the nature of the problem being treated, the overall health of the animal, and with the method of treatment. As much as a one month initial trial may be required to see significant reductions in symptoms. Contraindications Alpha-Stim may affect the operation of implanted demand type cardiac pacemakers and implanted defibrillators. Do not stimulate directly on the eyes, or press the probes over the carotid sinus (on the neck near the larynx). Precautions For external use only. Do not allow children to use or handle these devices without adult supervision. Safety of stimulation has not been established during pregnancy. Adverse Effects Adverse effects are usually mild and self-limiting. Adverse effects from data on approximately 8,800 patients participating in 144 controlled studies, open clinical trials, and uncontrolled conditions, and by physician survey and reasonably associated with the use of CES and MET are dizziness (6 cases, 0.07%), skin irritation/ electrode burns (6 cases, 0.07%), and headaches (9 cases, 0.10%). Prolonged CES treatment at currents higher than necessary may cause dizziness or nausea that can last for hours to days. Treatment immediately prior to going to sleep may cause difficulty sleeping. Electromedical Products International, Inc. ISO 13485:2003 A28461 Type BF Equipment. This stimulator is internally powered only. See instructions for use. Read the manual thoroughly before using. Alpha-Stim and the Alpha-Stim logo are registered trademarks, and LET NOTHING STOP THEM is a trademark of Electromedical Products International, Inc. 2018 Electromedical Products International, Inc. All rights reserved. Manufactured under US Patents 8,612,008; 8,457,765; and 8,463,406. Read a full disclosure of the minor and self-limiting risks here: alpha-stim.com/risk. REV B