Streptomycin Sulfate According to USP

Similar documents
Determination of gentamicin and related impurities in gentamicin sulfate

Compliance. Should you have any questions, please contact Praveen Pabba, Ph.D., ( or

AMOXICILLIN AND CLAVULANIC ACID TABLETS Draft proposal for The International Pharmacopoeia (February 2018)

Should you have any questions, please contact Edith Chang, Ph.D., Senior Scientific Liaison ( or

Determination of Streptomycin and Impurities Using HPAE-PAD

VALIDATED RP-HPLC METHOD FOR THE SIMULTANEOUS DETERMINATION OF AMLODIPINE BESYLATE AND ATORVASTATIN CALCIUM IN BULK AND PHARMACEUTICAL FORMULATION

Determination of ofloxacin in bulk drug and pharmaceutical dosage form by high performance liquid chromatography method

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF ALISKIREN AND AMLODIPINE IN TABLET DOSAGE FORM

Journal of Applied Pharmaceutical Research ISSN No

C 22 H 28 FNa 2 O 8 Pıı516.4

Isocratic Reverse Phase High Performance Liquid Chromatographic Estimation of Ramipril and Amlodipine in Pharmaceutical Dosage Form

Pharma Research Library. 2013, Vol. 1(1):19-29

MOXIFLOXACIN HYDROCHLORIDE (MOXIFLOXACINI HYDROCHLORIDUM) Draft proposal for The International Pharmacopoeia. (January 2018)

DETERMINATION OF ACTIVE SUBSTANCES IN MULTICOMPONENT VETERINARY PREPARATIONS OF ANTIPARASITIC ACTION BY HPLC METHOD

Development and Validation of RP-HPLC Method for Determination of Related Substances of Medetomidine in Bulk Drug

Development and Validation of Amlodipine Impurities in Amlodipine Tablets Using Design Space Computer Modeling

Amlodipine, Valsartan, and Hydrochlorothiazide Tablets

Journal of Global Trends in Pharmaceutical Sciences

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF AMLODIPINE BESYLATE AND IRBESARTAN

Development and validation of a HPLC analytical assay method for amlodipine besylate tablets: A Potent Ca +2 channel blocker

International Journal of Pharmaceutical Research & Analysis

SPECTROPHOTOMETRIC ESTIMATION OF MELOXICAM IN BULK AND ITS PHARMACEUTICAL FORMULATIONS

European Journal of Biomedical and Pharmaceutical ISSN Sciences

Tamboli Ashpak Mubarak et al. IRJP 2 (8)

METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF OFLOXACIN AND ORNIDAZOLE IN TABLET DOSAGE FORM BY RP-HPLC

Ultra-Fast Analysis of Contaminant Residue from Propolis by LC/MS/MS Using SPE

Method development and validation for simultaneous estimation of telmisartan and amlodipine by RP-HPLC

Deptt of Pharma Science SGRR ITS Patel Nagar, Dehradun (UK)

Sensitive and selective analysis of fipronil residues in eggs using Thermo Scientific GC-MS/MS triple quadrupole technology

Determination of Acaricides in Korean Honey Bull. Korean Chem. Soc. 2008, Vol. 29, No

HPLC method for simultaneous determination of Albendazole metabolites in plasma

Sci Pharm

Development and validation of HPLC method for simultaneous estimation of Amlodipine besylate and Enalapril maleate in solid dosage form

Quantification of Albendazole in Dewormer Formulations in the Kenyan market

ABSTRACT. Usharani N, Divya K and Ashrtiha VVS. Original Article

Detection of residues of quinolones in milk

Development and Validation of UV Spectrophotometric Area Under Curve (AUC) method for estimation of Pyrantel Pamoate in Bulk and Tablet Dosage Form

Rapid LC-MS/MS Method for the Analysis of Fipronil and Amitraz Insecticides and Associated Metabolites in Egg and Other Poultry Products

Multi-residue Method II for Veterinary Drugs by HPLC (Animal and Fishery Products)

Development and Validation of a RP-HPLC Method for Simultaneous Determination of Levofloxacin and Moxifloxacin in Pharmaceutical Dosage Forms

Determination of Benzimidazole Residues in Animal Tissue by Ultra High Performance Liquid Chromatography Tandem Mass Spectrometry

Asian Journal of Pharmaceutical Research and Development (An International Peer-Reviewed Journal of Pharmaceutical Research and Development)

Specific and Simple HPLC Assay of Ecofriendly Meloxicam in Pharmaceutical Formulations K.T. Mahmood 1, B.Khan 2, M. Ashraf 3 and I. U.

Determination, Confirmation and Quantitation of Multi-Class Antibiotic Residues in Milk by UHPLC MS/MS

Available online International Journal of Pharmaceutical Research & Allied Sciences, 2016, 5(4):37-44.

A VALIDATED HPLC-ASSAY FOR THE DETERMINATION OF MELOXICAM IN PRESENCE OF ITS DEGRADATION PRODUCTS

Quantification of Chloramphenicol in Chicken Using Xevo TQD with RADAR Technology

Validation of assay indicating method development of meloxicam in bulk and some of its tablet dosage forms by RP-HPLC

Veterinary Drug Detection in Pork and Milk

[ APPLICATION NOTE ] Analysis of Ketamine and Xylazine in Rat Tissues Using the ACQUITY UPLC with 2D Technology APPLICATION BENEFITS INTRODUCTION

Development And Validation Of Methods For Estimation Of Pimobendan In Pharmaceutical Dosage Form

PO. Vasan, Gandhinagar District, Gujarat, India, 3 Dean at Faculty of Pharmacy, Dharmsinh Desai University, Nadiad, Gujarat, India.

SIMPLE U.V. SPECTROPHOTOMETRIC METHODS FOR THE ESTIMATION OF OFLOXACIN IN PHARMACEUTICAL FORMULATIONS

Multi-residue Screening of Veterinary Drugs (I) and (II) in Meat According to the Japan Positive List Using Cartridge-based SPE and LC-MS/MS

ANTIBIOTICS RESIDUES IN HONEY: VALIDATION PROCEDURE HONEY ANALYTICAL METHODS VALIDATION

Stability indicating HPLC Method Validation for the Assay of Dexmedetomidine in Dexmedetomidine Hydrochloride Injection

Development and method validation on stress degradation studies of cefpodoxime proxetil and clavulanic acid in dosage form by hplc method

Stability of Nafcillin Sodium Solutions in the Accufuser Elastomeric Infusion Device

A reverse phase high performance liquid chromatography method was developed for simultaneous estimation of

Novel RP-HPLC Method Development and Validation of Meloxicam Suppository

Pradhan Prasanna Kumar et al. Int. Res. J. Pharm. 2014, 5 (9) INTERNATIONAL RESEARCH JOURNAL OF PHARMACY

SIMPLE HPLC METHOD FOR THE DETERMINATION OF CEFIXIME, OFLOXACIN AND LINEZOLID IN SOLID DOSAGE FORMS

Stability indicating HPLC method for the simultaneous determination of moxifloxacin and prednisolone in pharmaceutical formulations

ANTIBIOTICS IN PLASMA

Scholars Research Library

Chandra Mohan Rao Kota et al INTERNATIONAL JOURNAL OF RESEARCH AND REVIEWS IN PHARMACY AND APPLIED SCIENCES

A NOVEL STABILITY INDICATING RP-HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF MOXIFLOXACIN AND PREDNISOLONE IN BULK AND THEIR COMBINED DOSAGE FORM

ANALYTICAL METHOD VALIDATION FOR DETERMINATION OF RELATED SUBSTANCES OF DEXMEDETOMIDINE (IMPURITY-1) IN DEXMEDETOMIDINE HYDROCHLORIDE INJECTION

New Stability Indicating Method for Quantification of Impurities in Amlodipine and Benazepril Capsules by Validated HPLC

Medical Genetics and Diagnosis Lab #3. Gel electrophoresis

Triline Pumps. Vacuum & Pressure Gas moving Engineers. Diaphragm Pumps EVM Series

Amlodipine and Valsartan Tablets

Determination of Total Taurine in Pet Foods by Liquid Chromatography of the Dansyl Derivative: Collaborative Study

Stability of Tylosin in Honey Impact on Residue Analysis Don Noot, Tom Thompson

RP-HPLC Method for Simultaneous Estimation of Enalapril Maleate and Chlorthalidone in Synthetic Mixture

BIOLACTAM. Product Description. An innovative in vitro diagnostic for the rapid quantitative determination of ß-lactamase activity

Determination of Amlodipine in Rat Plasma by UV Spectroscopy

STABILITY INDICATING RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF MOXIFLOXACIN

SUMMARY OF PRODUCT CHARACTERISTICS. Lincomycin (as Lincomycin hydrochloride) Neomycin (as Neomycin sulphate) Excipients Disodium edetate

INTERNATIONAL RESEARCH JOURNAL OF PHARMACY

Supplementary information

Public Assessment Report. Scientific discussion. Xiflodrop 5 mg/ml eye drops, solution. Moxifloxacin hydrochloride DK/H/2221/001/DC

DEVELOPMENT OF A REVERSED PHASE - HPLC METHOD FOR DETERMINATION OF MELOXICAM IN TABLET FORMULATION AND HUMAN SERUM

Stability Indicating Spectrophotometric Method of Amlodipine and Telmisartan in Bulk and Pharmaceutical Dosage Form

Original Article. Abstract INTRODUCTION

A Simple Sample Preparation with HPLC UV Method for Estimation of Amlodipine from Plasma: Application to Bioequivalence Study

A Validated RP-HPLC Method for Simultaneous Estimation of Nebivolol Hydrochloride and S-Amlodipine Besylate in Tablet Dosage Forms

Extraction and Cleanup Protocols for LC-MS/MS Multiresidue Determination of Veterinary Drugs in Tissue and Milk Samples

Screening 36 Veterinary Drugs in Animal Origin Food by LC/MS/MS Combined with Modified QuEChERS Method

Fig.1: Structure of Desloratadine

Analysis of Amikacin in Human Serum By UHPLC with Fluorescence Detector Using Chloro-Formate Reagent With Glycine

European Public MRL assessment report (EPMAR)

Determination of Beta-Lactamase Inactivation of Cephalexin by Validated RP-HPLC Method

Multi-residue Automated Turbulent Flow Online LC-MS/MS Method for the Determination of Antibiotics in Milk

STABILITY INDICATING HPLC METHOD FOR THE QUANTIFICATION OF CEFIXIME, ORNIDAZOLE AND MOXIFLOXACIN IN SOLID DOSAGE FORMS

Kamepalli Sujana et al. / Journal of Pharmacy Research 2014,8(12), Available online through

Automated Online Multi-Residue LC-MS/MS Method for the Determination of Antibiotics in Chicken Meat

Quantification of EPA 1694 Pharmaceuticals and Personal Care Products in Water at the ng/l Level Utilizing Online Sample Preparation with LC-MS/MS

COMMITTEE FOR MEDICINAL PRODUCTS FOR VETERINARY USE

Introduction to Pharmacokinetics and Pharmacodynamics

Transcription:

Application Note Antibiotics The most reliable LC-EC applications for Antibiotics analysis Aminoglycosides Amikacin Framycetin Sulphate Gentamicin Sulphate Kanamycin Sulphate Lincomycin Neomycin Spectinomycin Tobramycin Macrolide antibiotics Azithromycin Azaerythromycin Clarithromycin Erythromycin Roxithromycin Streptomycin Sulfate According to USP n Meets all requirements of U.S. Pharmacopeia 38-NF33, 2015 n ALEXYS Aminoglycoside Analyzer with AEC n Flow cell with Au working electrode and stainless steel AUX n Reproducible and robust Summary The Streptomycin sulphate analysis was evaluated using the exact method and conditions described in the official 2015 USP monograph [5]. In this application note typical results obtained with the ALEXYS LC-EC aminoglycosides analyzer are reported, demonstrating its performance for the assay of Streptomycin sulphate in commercial pharmaceutical preparations. ALEXYS Application Note # 217_036_03 Electrochemistry Discover the difference

Introduction Streptomycin was the first aminoglycoside antibiotic described in 1944 by Waksman et al [1] and is produced by microbial fermentation of the actinobacterium Streptomyces griseus. It was shown to inhibit the growth of aerobic grampositive and gram-negative bacteria as well as the tubercle bacilli, and was in fact the first effective treatment for tuberculosis. Besides its common use for clinical treatment in humans it is also utilized as veterinary drugs and crop-protection agent. Like other aminoglycosides, streptomycin is potentially oto- and nephrotoxic. Streptomycin and its derivatives can be analyzed using ion-pair reversed phase liquid chromatography (RP-LC) in combination with UV detection at 195 nm or 205 nm [2,3], but this method had limitations. It requires high concentrations of the compounds to be detected by UV absorbance due to the absence of a good chromophore. Pulsed Amperometric Detection (PAD) is a better choice. Streptomycin and its impurities have a molecular structure which contain functional groups which can be oxidized and detected by PAD with superior selectivity and sensitivity [4]. The U.S. as Polystyrene/divinylbenzene substrate agglomerated with quaternary amine functionalized latex beads, about 9 µm to 11 µm in diameter. The CarboPac PA1, 250 x 4.0 mm ID analytical column which has a L46 packing was chosen for the method evaluation. The analytical column was used in combination with a CarboPac PA1 guard column with the dimensions 50 x 4.0 mm. Table 1 LC-EC Conditions HPLC ALEXYS LC-EC Analyzer with low-pressure mobile phase selector Column CarboPac PA1 250 x 4 mm ID analytical column + CarboPac PA1 50 x 4 mm ID guard column (USP column packing L46) Mobile phase Flow rate Vinjection 20 µl Temperature Flow cell Potential waveform (4-step) 70mM sodium hydroxide (analysis), 200mM sodium hydroxide (column clean-up). 0.5 ml/min I-cell ca. 0.3 µa ADF 30 C for separation & detection SenCell* with Au WE, stainless steel AE and Ag/AgCl RE, AST 2 E1, E2, E3, E4: +0.1, -2.0, +0.6, -0.1 V ts, t1, t2, t3, t4: 0.2, 0.4, 0.02, 0.01, 0.07 s 0.5 Hz Range 2 µa *Originally used: VT-03 with Au WE, stainless steel AE and Ag/AgCl RE, spacer 50 µm Figure 1: ALEXYS Aminoglycoside Analyzer for Streptomycin. Method The USP (38-NF33) method for streptomycin sulfate is based on isocratic separation using an anion exchange column and alkaline mobile phase (ph = 12.8) followed by PAD. One of the thermal degradation products of streptomycin (induced by heating the standard solution for 1 hour at 75 C) is used to check the system suitability of the assay. Separation In the monograph the use of the following column type is described for the separation of Streptomycin: size 250 x 4 mm ID analytical column containing a L46 packing, which is defined The analysis is based on a step-gradient, see table 2. A column clean-up/regeneration step after isocratic elution is necessary to remove late eluting (thermal) degradation products present in the Streptomycin products and standards. These degradation products may result from storage or chemical degradation during manufacture. Especially the heat-treated system suitability standard exhibits a large late eluting impurity response. Under isocratic conditions (70 mm NaOH) this impurity elutes after 160 minutes under isocratic conditions. The ALEXYS LC-EC Analyzer was equipped with only one LC pump and a Vici electrically-actuated low pressure (LP) valve in the pump LP suction line to switch between mobile phase (70 mm NaOH) and the mobile phase for column clean-up (200 mm NaOH). The eluents were carefully prepared manually using a commercial 50% NaOH solution, carbonate-free. The diluent was deionized Water (resistivity >18 MΩ-cm) which was sonicated and sparged with Helium 5.0 prior to use. The appropriate amount of NaOH was carefully pipetted into the diluent to minimize the introduction of carbonate in the solution. The bottles with mobile phase and column 2

clean-up solution were blanketed with Helium during the analysis to minimize the build-up of carbonate ions in the mobile phase and to assure a reproducible analysis. Table 2 Step-gradient program Time (min) Mobile phase Description 0-22 70 mm NaOH Isocratic elution & detection 22-40 200 mm NaOH Column clean-up/regeneration 40-85 70 mm NaOH Re-equilibration to starting conditions Detection For the detection of Streptomycin using PAD a flow cell is required with an Au working electrode (WE), Ag/AgCl reference electrode (RE) and stainless steel auxiliary electrode (AE). The Antec electrochemical flow cell matches these require - ments and was used in this evaluation. A 4-step potential waveform is used as described in the USP monograph to detect streptomycin and its impurities on the Au working electrode, see Table 1 and Figure 2 below. Sample preparation Standard preparation: 15 mg of USP Streptomycin Sulfate RS was accurately weighted and dissolved in 50 ml of water in a volumetric flask (sonicated for 1 minute and mixed). The obtained solution was subsequently 10x diluted using a 100 ml volumetric flask to obtain a final concentration of 0.03 mg/ml. System suitability solution: 10 ml of the above mentioned standard was heated to 75 C for 1 hour and cooled down to ambient prior to use. Assay preparation: 30 mg of a commercial Streptomycin Sulfate sample (Sigma-Aldrich, pn S6501, batch SLBD3728V) was transferred to a 100 ml volumetric flask and diluted with water to volume (sonicated for 1 minute and mixed). 10 ml was subsequently transferred to a second 100 ml volumetric flask and diluted to volume with water, resulting in a final concentration of 0.03 mg/ml. Loss on drying Prior to use the water contents of the commercial Streptomycin Sulfate sample was determined as specified in the monograph (loss on drying). An accurately weighted amount (around 100 mg) of Streptomycin sample was dried under vacuum (5 mmhg) at 60 C for 3 hours. The dried sample was re-weighted and the loss on drying calculated. This analysis was performed in duplicate and an average weight loss of 3.4% was found. The measured weight loss of the sample was within the USP criteria (< 5.0%). The weight loss reported by the manufacturer of this specific sample in the certificate of analysis was 3.1%. Figure 2: Applied PAD waveform as described in the USP monograph. The temperature for separation and detection was set to 30 C. The cell current was typical about 0.3 µa with these PAD settings under the specified conditions. This particular 4-step waveform with a pulse duration of 500 ms has been claimed to have as benefits: (1) a consistent long-term peak area response and (2) minimal electrode wear [6]. Note that an ALEX- YS LC-EC system with the new DECADE Elite electrochemical detector is required for PAD detection using a 4-step potential waveform. Results System Suitability In Figure 3 an overlay is shown of the chromatograms obtained with the USP standard solution (red curve) and the system suitability solution (blue curve).the retention times for the system suitability peak and Streptomycin were 6.55 and 13.08 minutes, respectively. It is evident from Figure 3 that the reponse of the main degradation product at 6.55 min increased significantly (more than 18 fold increase in peak height). 3

Table 3 USP system suitability requirement Parameter Relative retention time (main degradation product) Resolution (between main degradation product & Streptomycin) USP Measured criteria 0.5 0.5 > 3.0 11.3 Column efficiency (Streptomycin) >1000 3853 Tailing factor (Streptomycin) <2.0 1.5 RSD peak area, n=6 (Streptomycin) <5% 0.7% The system suitability is evaluated using the chromatogram shown in Figure 3. The results are listed in table 3, it is evident that the system suitability requirements are met for all performance parameters. Figure 3: Chromatogram overlay of a system suitability solution (blue), and standard (red), both containing 30 µg/ml Streptomycin RS in water. Only the system suitability solution was heated for 1 hour at 75 C. The main degradation peak is designated system suitability peak in the chromatogram. In the USP monograph for Streptomycin Sulfate the following system suitability requirements are specified: n Relative retention time: about 0.5 for the main degradation product and 1.0 for the Streptomycin peak in the chromatogram obtained with the system suitability solution. n Resolution: not less than 3 between Streptomycin and main degradation product peak in the chromatogram obtained with the system suitability solution. n Column efficiency: not less than 1000 theoretical plates for the Streptomycin peak in the chromatogram obtained with the standard solution. n Tailing factor: not more than 2.0 for the Streptomycin peak in the chromatogram obtained with the standard solution. n Relative standard deviation: not more than 5% (Area of Streptomycin peak) for replicate injections of the standard solution. Linearity, repeatability & LOD The linearity for Streptomycin was investigated in the concentration range of 5 µg/ml 40 µg/ml. In this concentration range the correlation coefficient for peak area was better than 0.995. The relative standard deviation (RSD) of the retention time, peak area and height were determined for 6 replicate injections of the USP Streptomycin Sulfate RS standard solution. The RSD s were 0.1%, 0.5% and 0.5%, respectively for the Streptomycin peak. The Limit of Detection (LOD) for Streptomycin, calculated as the analyte response corresponding to 3x the ASTM noise (average peak-to-peak baseline noise of 30 segments of 0.5 min), was about 0.1 µmol/l (70 ng/ml). Sample analysis As an example a commercial sample was analyzed from Sigma Aldrich: S6501 Streptomycin sulfate salt (batch SLBD3728V). The sample is abbreviated as sample SLBD3728V from this point onwards. The chromatogram obtained from the sample solution is shown in Figure 4. 4

Table 4 Assay Sample USP criteria µg/mg Measured SLBD3728V 650-850 717 The contents of Streptomycin in the analyzed Streptomycin sulfate sample was within the specified limits of the USP monograph. Figure 4: Analysis of Streptomycin sample SLBD3728V, 30 µg/ml in water. The potency (contents) of the Streptomycin sulfate sample SLBD3728V, defined as the quantity of Streptomycin (C21H39N7O12) in µg per mg Streptomycin sulfate, is calculated as follows: Potency (in µg/mg) = 1000 x (C x P / WU) x (ru / rs) Where: C = Concentration in mg/ml of the USP Streptomycin Sulfate RS in the standard preparation. P = Designated Streptomycin contents in µg per mg USP Streptomycin Sulfate RS. Wu = Weight, in mg, of the Streptomycin sample taken to prepare the assay preparation. ru = Streptomycin peak area obtain from the chromatogram of the assay preparation. rs = Streptomycin peak area obtain from the chromatogram of the standard preparation. Conclusion The ALEXYS Aminoglycosides Analyzer offers a tailored solution to assay Streptomycin sulfate using the official method of the USP. The USP acceptance criteria for the Streptomycin potency in Streptomycin Sulfate is that the product should have a potency not less than 650 µg and not more than 850 µg of Streptomycin (C21H39N7O12) per mg. The result for sample SLBD3728V is listed in Table 4. 5

References 1. S.A. Waksman, Streptomycin: Background, Isolation, Properties and Utilization, Science, 118 (1953), 259-266 2. T.J. Whall, Determination of Streptomycin sulfate and Dihydrostreptomycin Sulfate by High-Performance Liquid Chromatography, J. Chromatogr., 219 (1981), 89-100 3. E. Adams, M. Rafiee, E. Roets, J. Hoogmartens, Liquid Chromatographic Analysis of Streptomycin Sulfate, J. Pharm. Biomed. Anal., 24 (2000), 219 226 4. W.R. LaCourse, Pulsed Electrochemical Detection in High Performance Liquid Chromatography, John Wiley & Sons, New York, 1ed, 1997 5. Streptomycin Sulfate, The United States Pharmacopeia 38th ed., National Formulary 33th, United States Pharmacopeial Convention, Rockville MD, (2015), 5360 6. R.D. Rocklin, A.P. Clarke, M. Weitzhandler, Improved longterm reproducibility for pulsed amperometric detection of carbohydrates via a new quadruple-potential waveform, Anal. Chem, 70, (1998), 1496-1501 Ordering information 180.0051E ALEXYS Aminoglycosides Analyzer for Streptomycin, including column and flow cell 250.0033E LP solvent selector option, 4-port,1/4-28 250.1076 CarboPac PA1, 250 x 4.0 mm ID 250.1077 CarboPac PA1 guard, 50 x 4.0 mm ID Antec Scientific (USA) info@antecscientific.com www.antecscientific.com T 888 572 0012 Antec Scientific (worldwide) info@antecscientific.com www.antecscientific.com T +31 71 5813333 For research purpose only. The information shown in this communication is solely to demonstrate the applicability of the ALEXYS system. The actual performance may be affected by factors beyond Antec s control. Specifications mentioned in this application note are subject to change without further notice. 6