arxiv: v1 [physics.optics] 8 Feb 2015

Similar documents
Optoacoustic imaging of an animal model of prostate cancer

Biomedical Photoacoustic Imaging Using Gascoupled Laser Acoustic Detection

Gigahertz optoacoustic imaging for cellular imaging

Examination of Contrast Mechanisms in Optoacoustic Imaging of Thermal Lesions

Use of a pulsed fibre laser as an excitation source for photoacoustic tomography.

Photoacoustic imaging is an emerging modality based

Fiber optic photoacoustic probe with ultrasonic tracking for guiding minimally invasive procedures

Improved Photoacoustic Generator

Photoacoustic Molecular Imaging using Single Walled Carbon Nanotubes in Living Mice. Bioengineering, Stanford University, Palo Alto, CA 94305, USA.

The strengths and weaknesses of the optoacoustic method: is combining light and sound always beneficial?

TECHNISCHE UNIVERSITÄT MÜNCHEN. Fakultät für Elektrotechnik und Informationstechnik. Lehrstuhl für Biologische Bildgebung

arxiv: v1 [physics.optics] 10 Dec 2015

Carbon nanotubes as photoacoustic molecular imaging agents in living mice

Adding fifth dimension to optoacoustic imaging: volumetric time-resolved spectrally enriched tomography

DLS Sample Preparation Guide

Medical Imaging Techniques Combining Light and Ultrasound

P hotoacoustic imaging has the

TECHNISCHE UNIVERSITÄT MÜNCHEN

1380 IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. 61, NO. 5, MAY Small-Animal Whole-Body Photoacoustic Tomography: A Review

FCI LT LM UNDERGROUND

F irst optoacoustic images from living biological tissues were demonstrated over a decade ago1,2. The unique

NIH Public Access Author Manuscript Electromagn Waves (Camb). Author manuscript; available in PMC 2015 January 30.

High Sensitivity of In Vivo Detection of Gold Nanorods Using a Laser Optoacoustic Imaging System

PHOTOACOUSTIC TOMOGRAPHY:

Improving the Safety of Telerobotic Drilling of the Skull Base via Photoacoustic Sensing of the Carotid Arteries

Performance Analysis of HOM in LTE Small Cell

(12) United States Patent

Fiber-Optic Accessories

SILVER SCOPE Veterinary Videoendoscopes

Page 1. Outline. Photoacoustic Tomography: Multiscale Imaging from Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

A Flexible natural gas membrane Reformer for m- CHP applications FERRET

PHOTOACOUSTIC TOMOGRAPHY: Ultrasonically Breaking through the Optical Diffusion Limit

Supplementary information

WATERBOX PLATINUM SERIES

MGL Avionics EFIS G2 and iefis. Guide to using the MGL RDAC CAN interface with the UL Power engines

Effects of Cage Stocking Density on Feeding Behaviors of Group-Housed Laying Hens

Simrad ITI Trawl monitoring system

Status of Electronics Upgrades to the LANL Green is Clean Phoswich Detector Systems 16419

Multi-Frequency Study of the B3 VLA Sample. I GHz Data

Study on Acoustic Features of Laying Hens Vocalization

AmpFlex Flexible Current Probes

Penn Vet s New Bolton Center Launches Revolutionary Robotics-Controlled Equine Imaging System New technology will benefit animals and humans

ENGINEERING TEST SPECIFICATION

A Flexible natural gas membrane Reformer for m- CHP applications FERRET

Australian and New Zealand College of Veterinary Scientists. Membership Examination. Veterinary Radiology (Small Animal) Paper 1

A Novel Approach For Error Detection And Correction Using Prefix-Adders

A versatile new imaging modality for biomedical research. Listening to Molecules

Modeling and Control of Trawl Systems

Active sensing. Ehud Ahissar

Sentinel lymph node (SLN) biopsy (SLNB) has emerged as the preferred method for axillary lymph node staging of breast cancer patients with clinically

Australian Journal of Basic and Applied Sciences. Performance Analysis of Different Types of Adder Using 3-Transistor XOR Gate

PRODUCT FAMILY DATASHEET LED SUPERSTAR CLASSIC B DIM

ICAO WCO Joint Conference on Enhancing Air Cargo Security and Facilitation

Prosthetic Feet. Geriatric-Foot, light, 10 mm heel

ULTRAVIOL. UltraViol is a dynamically developing. We invite you to become our business partner.

16-BIT CARRY SELECT ADDER. Anushree Garg B.Tech Scholar, JVW, University, Rajasthan, India

Trends and challenges in Engineering geodesy

Triline Pumps. Vacuum & Pressure Gas moving Engineers. Diaphragm Pumps EVM Series

Introduction. Analysis of Commercial Products

288 Seymour River Place North Vancouver, BC V7H 1W6

Single Port Modular Jacks

Imaging and Sensing 2013

HALE SECURITY PET DOOR CAT GUARDIAN patent pending

[Boston March for Science 2017 photo Hendrik Strobelt]

Australian and New Zealand College of Veterinary Scientists. Membership Examination. Veterinary Radiology (Small Animal) Paper 1

AMOXICILLIN AND CLAVULANIC ACID TABLETS Draft proposal for The International Pharmacopoeia (February 2018)

STUDY BEHAVIOR OF CERTAIN PARAMETERS AFFECTING ASSESSMENT OF THE QUALITY OF QUAIL EGGS BY COMPUTER VISION SYSTEM

Protocol for fabrication of microcompartments for long-term culture and imaging of small C. elegans larvae. Henrik Bringmann, March 2011.

Evaluation of the hair growth and retention activity of two solutions on human hair explants

PROCEEDINGS OF SPIE. Event: SPIE BiOS, 2008, San Jose, California, United States

FPGA-based Emotional Behavior Design for Pet Robot

EVM analysis of an Interference Limited SIMO-SC System With Independent and Correlated Channels

Optoacoustic 3D visualization of changes in physiological properties of mouse tissues from live to postmortem

Pet-Temp PT-300 Ear Thermometer Frequently Asked Questions

Ultra-Fast Analysis of Contaminant Residue from Propolis by LC/MS/MS Using SPE

Outdoor Bark Control

E. Liischer/P. Korpiun H. J. Coufai/R. Tilgner (Eds.) Photoacoustic Effect

Module Egg. MODULE NO. 25: Internal Quality of Egg

Session Fur & Wool. Qian Q.X., Ma J.X., Zhang G.Z., Xie C.S., Ren L., Qian B.Q. BREEDING AND APPLICATION OF ZHEXI ANGORA RABBITS.

Pareto Points in SRAM Design Using the Sleepy Stack Approach

NA 100 R. Multi-functional electrophoresis device

Sensitive and selective analysis of fipronil residues in eggs using Thermo Scientific GC-MS/MS triple quadrupole technology

A Critical Consideration of the Blink Reflex as a Means for Laser Safety Regulations

Design of 16-Bit Adder Structures - Performance Comparison

TITLE: Anti-Inflammatory Cytokine Il-10 and Mammary Gland Development. CONTRACTING ORGANIZATION: University of Buffalo Buffalo, New York

Research Article Design of Information System for Milking Dairy Cattle and Detection of Mastitis

The challenges of implementing a "patient-oriented" telepathology network; the Eastern Québec telepathology project experience

FAQ (Frequently Asked Questions)

IQ Range. Electrical Data 3-Phase Power Supplies. Keeping the World Flowing

BuzziLight V Product Specification Sheet. Mono Alhambra Royal

Pure Paws Explains Methods For Improving A White Coat

Abstract 2. Introduction 3. Materials and Methods 5 Safety 5 Materials (list) 5 Procedure 5. Results 8 Discussion 15.

ULTRAVIOL. UltraViol is a dynamically developing. We invite you to become our business partner.

FerriNaphth: A Fluorescent Dosimeter for Redox Active Metals

Quick Setup Guide Model 5134G

ReproMatic & FluxxBreeder

USER S GUIDE DECLARATION «CE» DE CONFORMITE «EC» DECLARATION OF CONFORMITY. NUM AXES déclare que / declares that

SUPPLEMENTARY INFORMATION

Microchipping Works: Best Practices

Objectives. Materials TI-73 CBL 2. Strainer. Gravel

Transcription:

Optical-resolution photoacoustic imaging through thick tissue with a thin capillary as a dual optical-in acoustic-out waveguide Olivier Simandoux, 1 Nicolino Stasio, 2 Jérome Gateau, 1 Jean-Pierre Huignard, 3 Christophe Moser, 4 Demetri Psaltis, 2 and Emmanuel Bossy 1,a) 1) ESPCI ParisTech, PSL Research University, CNRS, INSERM, Institut Langevin, arxiv:1502.02213v1 [physics.optics] 8 Feb 2015 1 rue Jussieu, 75005 Paris, France 2) Ecole Polytechnique Fédérale de Lausanne, Laboratory of Optics, CH-1015 Lausanne, Switzerland 3) Jphopto-consultant, 20 rue Campo Formio, 75013 Paris, France 4) Ecole Polytechnique Fédérale de Lausanne, Laboratory of Applied Photonics Devices, CH-1015 Lausanne, Switzerland We demonstrate the ability to guide high-frequency photoacoustic waves through thick tissue with a water-filled silica-capillary (150 µm inner diameter and 30 mm long). An optical-resolution photoacoustic image of a 30 µm diameter absorbing nylon thread was obtained by guiding the acoustic waves in the capillary through a 3 cm thick fat layer. The transmission loss through the capillary was about -20 db, much lower than the -120 db acoustic attenuation through the fat layer. The overwhelming acoustic attenuation of high-frequency acoustic waves by biological tissue can therefore be avoided by the use of a small footprint capillary acoustic waveguide for remote detection. We finally demonstrate that the capillary can be used as a dual optical-in acoustic-out waveguide, paving the way for the development of minimally invasive optical-resolution photoacoustic endoscopes free of any acoustic or optical elements at their imaging tip. Keywords: Biomedical Imaging; Photoacoustic Endoscopy; Optical Resolution; Acoustic Attenuation a) Electronic mail: emmanuel.bossy@espci.fr 1

Biomedical photoacoustic imaging is a rapidly emerging imaging modality that has the unique capability toprovideoptical absorptioncontrast imagesatdepth intissue 1 3. Itrelies on the conversion of optical energy into acoustic waves. Amplitude modulated light, usually a laser pulse, is sent on the tissue of interest, penetrates the tissue and, as a consequence of the thermoelastic effect, photoacoustic waves are generated where light is absorbed. One of the advantages of photoacoustic imaging is that it can either provide label-free images of tissues based on the intrinsic variations of the absorption coefficient 4,5, or images based on exogenous contrast agents that can be used to target specific structures or metabolisms 6 8. In photoacoustic imaging there is an important trade-off between resolution and penetration depth 1,2. High resolution images require the detection of high frequency acoustic waves associated with high acoustic attenuation in tissue, thus limiting the distance between the absorbing structure and the ultrasound detection in high-resolution photoacoustic imaging. Photoacoustic imaging approaches can be divided in two categories based on the physical process that defines the image resolution 1,2. In acoustic-resolution photoacoustic imaging (AR-PAI) the resolution of the system is dictated by the highest detected frequency and aperture of the acoustic detection device. In optical-resolution photoacoustic imaging (OR- PAI), light is focused to a diffraction limited spot and scanned to illuminate point by point the region to be imaged 9. This yields optical resolution as the generation of photoacoustic waves is restricted to the illuminated region in the tissue. OR-PAI can be used as a valuable complement, or an alternative, to optical microcopies for shallow tissue imaging as it can specifically provide images of optical absorption in tissue with optical resolution. AR-PAI can provide images at much greater depths, up to a few centimeters, but only with acoustic resolution 1,2. OR-PAI relies on the ability to focus light into the tissue of interest and to detect the high frequency components generated by the small-sized illuminated region. Therefore it is limited by optical scattering to penetration depths smaller than 1 mm(typical value of the optical transport mean free path in tissue 3 ) and by the acoustic attenuation of high frequency waves. At the cost of invasiveness, photoacoustic endoscopy allows imaging tissue at any depth by directly inserting an endoscopic device into tissue. Photoacoustic endoscopy was initially developed with acoustic resolution 10 12, and various devices have been developed since then 13. Optical-resolution photoacoustic endoscopy (OR-PAE) was then first introduced by Zemp and coworkers, by use of a bundle of single-mode optical fibers 14,15, as in conventional 2

Dopped silica Polyimide Silica Light 20 µm Sample Water Sound 75 µm 76.5 µm 10 µm FIG. 1. Schematic of the water-filled capillary used as a dual optical-in acoustic-out waveguide. Light is guided in the silica cladding 22 towards the image tip, while ultrasound is guided through the liquid core (the compressional and shear ultrasound velocity are respectively about 5970 m.s 1 and 3760 m.s 1, both much larger that the ultrasound velocity in water 1490 m.s 1 ) 23. optical endoscopy. The diameters of the experimental devices used typically ranged from 1 to a few millimeters. An alternative approach with a significantly smaller footprint than fiber bundles was recently proposed for optical endoscopy to address the issue of focusing and scanning light at depth in tissue, by use of thin multimode fibers (typically 200 µm in diameter) and optical wavefront shaping, either via digital phase conjugation (DPC) 16 or optical transmission matrix approaches 17. Optical phase conjugation focusing through a multimode fiber was subsequently applied for OR-PAE 18. Because OR-PAE generates photoacoustic waves with frequencies of typically several tens of MHz, the ability to detect externally the high frequency photoacoustic waves generated at depth in tissue is limited by the acoustic attenuation, typically 0.1-1.0 db/cm/mhz 19. In the two OR-PAE approaches introduced above 15,18, ultrasound was detected from outside either through a relatively thin tissue in the MHz range 15, or through a non-absorbing tissue phantom 18. Internal detection can be considered, but ultrasound sensors have to be miniaturized, resulting in limited sensitivity, and requiring dedicated technological developments 20,21. No endoscopic device is currently able to achieve both optical scanning and focusing and detection of the generated photoacoustic waves to generate an optical-resolution photoacoustic image at centimeters depth in tissue. In this work, we address the problem of detecting high frequency photoacoustic waves generated deep inside tissue for optical-resolution photoacoustic endoscopy. Classically, ultrasound detectors have been designed to detect the photoacoustic waves at the distal tip of minimally invasive devices inserted inside the tissue 20,21,24. Here we show that a water- 3

Focused transducer Signal acquisition Water tank Capillary 3 cm pork fat x z y Objective scan Objective Thread on distal tip of capillary z y x Pulsed laser 150 µm FIG. 2. Schematic of the experimental setup. The water-filled capillary is immersed in water and embedded in a pork fat layer. A microscope objective focuses and raster scans the optical spot around the distal tip of the capillary. The photoacoustic waves are transmitted through the hollow capillary and detected by a focused transducer. A 30 µm diameter black nylon thread, attached to the distal tip of the capillary, was used as absorbing sample (inset). filled capillary can be used to guide high frequency photoacoustic waves outside the tissue for remote ultrasound detection, thus avoiding absorption losses in tissue and the need for embedded miniaturized ultrasound detectors. We demonstrate in a second phase that the same capillary may also be used as an optical waveguide, and can therefore be used as a dual waveguide for both optical and acoustic waves. For both optics and acoustics, waves are guided into a core medium when the surrounding media have a lower index of refraction (or equivalently a higher phase velocity) 22,23. A schematic of the capillary (Polymicro Technologies, USA) used for our study is shown in Fig. 1, illustrating waveguiding for both optics and acoustics. The silica tubing acts as a multimode waveguide for visible light, while the water-filled core acts as a waveguide for ultrasound. The 150 µm inner diameter used in this work corresponds to an acoustic wavelength in water at 10 MHz. Therefore, for the ultrasound frequency range [5-30] MHz in this work, the acoustic waveguide can be considered a few-mode waveguide. In particular, the first-order quasi-piston mode exits the waveguide as a quasi-spherical wave, which can be detected by a spherically focused transducer. 4

To demonstrate optical-resolution imaging with acoustic detection through a capillary, the experimental setup presented in Fig. 2 was used. In this case, the sample was directly illuminated at the imaging tip, without using the capillary as an optical waveguide. The output of a Q-switched pulsed laser (wavelength 532 nm, pulse duration 4 ns, repetition rate 10 Hz, Brilliant, Quantel, France) was focused by a 40X, 0.6 NA microscope objective (LUCPLFLN, Olympus, Japan), with a typical spot diameter around 5 µm. The laser output energy was estimated around 1 µj/pulse. The sample (absorber + tissue layer), the ultrasound transducer and the capillary were immersed in a water tank. The objective was mounted on a two-axe motorized translation stage (M122.2DD, Physik Instrumente, Germany) installed below the water tank to mechanically raster scan the optical focus around the absorbing sample. A 30 mm long capillary was filled with water and was embedded in a 3 cm thick pork fat layer. The high acoustic attenuation of pork fat, and the significant thickness of the layer, were chosen to illustrate a situation in which the detection of high frequency photoacoustic signals at depth in tissue is highly challenging, if not impossible in practice. The distal tip, which corresponds to the entrance tip for the acoustic waves, exits the tissue close to the bottom of the water tank where the optical spot was raster scanned around the absorbing sample. The photoacoustic waves guided through the capillary fluid core (see Fig. 1) were detected at the proximal tip with a high frequency spherically focused transducer (20 MHz center frequency, 12.7 mm focal distance, 6.3 mm diameter, PI20-2- R0.50, Olympus, Japan). For each position of the focused optical spot, the photoacoustic signal was acquired by the transducer, amplified by a low noise amplifier (DPR500, remote pulser RP-L2, JSR Ultrasonics, USA), and digitized on an oscilloscope (DLM 2024, Yokogawa, Japan). The data was transferred to the computer used to control and synchronize the whole acquisition process. We first estimated the transmission loss through pork fat by comparing photoacoustic signals propagating through water to those propagating through a 1-cm thick fat layer (limited by the 12.7 mm focal length of the transducer). For these measurements, a homogeneously absorbing 23 µm thick polyester red layer (color film 60193, Réflectiv, France) fixed at the bottom of the water tank and the transducer was placed so that the optical focus on the layer corresponds to the focal point of the transducer (no capillary was used). A typically 40-dB attenuation through the 1 cm fat layer was observed on the peak-to-peak amplitude. The acoustic transmission through a 3 cm pork fat layer is therefore expected to be approxi- 5

(a) 30 µm (b) 30 µm 30 µm (c) Time time domain domain signal signal (volts) (volts) 0.5 0 water 0.5 8 0.1 9 10 11 0 0.1 capillary in 30 mm pork slice 27 Time time (µs) 29 30 (d) Spectrum (a.u) 1 0.8 0.6 0.4 0.2 0 10 20 30 Frequency (MHz) (e) FIG. 3. (a) Optical-resolution photoacoustic image of the thread obtained through water. (b) Optical-resolution photoacoustic image through a hollow capillary embedded in a 3 cm thick fat layer. The solid circle corresponds to the interfaces of the water-filled core, and the small and large dashed circles to the silica cladding and polyimide protective coating respectively. (c) White light optical image of the thread fixed at the distal tip of the hollow capillary. (d) Upper curve: typical time domain acoustic signal acquired through water only (average n= 128). Lower curve: typical time domain acoustic signal acquired through the capillary (average n= 1024). (e) Frequency analysis of the signals shown in (d). mately 120 db. The fat layer acted as a low-pass filter, as the acoustic attenuation increases with frequency. A spectral analysis showed that the central frequency of the signal is reduced from 17 MHz through water, close to the 20 MHz central frequency of the transducer, to only 5.5 MHz through the fat layer. We then demonstrated optical-resolution photoacoustic imaging with acoustic detection througha3-cmthick porklayer byuse ofthecapillary. A30µmdiameter black nylonthread (NYL02DS, Vetsuture, France) was used as the sample to image (see Fig. 2). In Fig. 3, the photoacoustic image and signal of the sample transmitted only in water, taken as references for our imaging system, were compared to the photoacoustic image and signal of the sample guided through the pork fat layer by the capillary. Optical-resolution photoacoustic images 6

were obtained by raster scanning of the optical focus spot and measuring the peak amplitude of the envelope of the acoustic signal detected at each scanning position. The pixel size is 5 µm 5 µm and fields of view are 400 µm 400 µm. To obtain the reference image and signal, a thread was fixed at the bottom of the water tank in the focal region of the transducer, and no pork fat or hollow capillary was used. In figure 3(a) we present the corresponding reference image of the thread. To form an image after propagation through the capillary across a 3 cm thick fat layer, the same absorbing thread was fixed at the distal tip of the hollow capillary (for easier alignment). The optical-resolution photoacoustic image obtained is presented in Fig. 3(b) and closely resembles the white light optical image (Fig. 3(c)): as expected, no loss of resolution is observed compared to the reference photoacoustic image in Fig. 3(a) and the field of view is reduced to a 150 µm diameter circle, corresponding to the capillary core. As illustrated by Fig. 3(d) plotting the temporal signals and their corresponding frequency spectra, the acoustic coupling in and out of the capillary and acoustic propagation through the capillary act as a low-pass filter. Moreover, temporal spreading of the signal measured through the capillary indicates modal dispersion. A typical -20 db decrease of the peak-to-peak amplitude is observed through the capillary as compared with propagation in free water, which however remains several orders of magnitude smaller than the expected attenuation through the fat layer. This decrease can be attributed to both dispersion and absorption losses in the capillary. Preliminary experimental and theoretical results 25 suggest that the main pulse in the capillary (observed at t 27.2 µs) corresponds to a quasi-piston mode which attenuation is predominantly due to shear viscous loss inside the water-filled core, in addition to possible leaking of the guided wave through the silica walls. A systematic experimental and theoretical study of the acoustic propagation and transmission losses through the capillary is being carried out for a deeper understanding of the transmission efficiency of the capillary as an acoustic waveguide, but was beyond the scope of this letter. Finally, we demonstrated that the capillary may be used as a dual waveguide for both optical and acoustic waves, with an imaging tip free of any optical or acoustic elements, all deported to the tip outside the tissue. The corresponding experimental setup is shown in Fig 4.a. A transparent 100 µm-thick glass slide was used to deflect the photoacoustic wave towards the ultrasound transducer oriented at 90 from the capillary, while letting through the illumination pulse. A photoacoustic signal emitted by a homogeneously absorbing 23 µm 7

Objective Glass slide Focused transducer Capillary Sample (a) Time domain signal (a.u) 1 0.5 0 0.5 21.5 22 22.5 23 23.5 24 24.5 25 Time time (µs) (b) FIG. 4. (a) Proof-of-concept setup used to demonstrate photoacoustic sensing by use of the capillary as a dual waveguide. All the elements are immersed in water for acoustic coupling. Light is coupled into the capillary cladding through a 100 µm-thick glass slide, which deflects the ultrasound guided through the water-filed cored towards the ultrasound transducer. The imaging tip (bottom tip) is free from any optical or acoustic elements. (b) Photoacoustic signal emitted from a homogeneously absorbing 23 µm thick polyester red layer placed at the imaging tip. thickpolyesterredlayerisshowninfig4.b. Itwasverifiedthatthelighttransmittedthrough the capillary was guided inside the silica cladding. The imaging resolution in this proofof-concept configuration is therefore limited by the dimension of the silica tube. However, the silica cladding can also be used as a multi-mode optical waveguide through which light may be focused by wavefront shaping techniques, such as optical phase conjugation already demonstrated for optical-resolution by Papadopoulos et al. 18 in a multi-mode fiber. In conclusion, our results therefore show that a fluid-fill silica capillary could be used as a dual mode waveguide (optical in, acoustic out) to perform optical-resolution photoacoustic imaging with an imaging tip free of any optical or acoustic elements (all being deported 8

to the tip outside the tissue), and pave the way for minimally invasive optical-resolution photoacoustic endoscopy. Olivier Simandoux gratefully acknowledges funding from the Direction Générale de l Armement (DGA). Jérome Gateau gratefully acknowledges funding from the Plan Cancer 2009-2013 (Action 1.1, Gold Fever). The work at Institut Langevin was partially funded by the LABEX WIFI(Laboratory of Excellence ANR-10-LABX-24) within the French Program Investments for the Future under reference ANR-10- IDEX-0001-02 PSL*. REFERENCES 1 P. Beard, Biomedical photoacoustic imaging, Interface Focus 1, 602 631 (2011). 2 L. V. Wang and S. Hu, Photoacoustic tomography: In vivo imaging from organelles to organs, Science 335, 1458 1462 (2012). 3 V. Ntziachristos, Going deeper than microscopy: the optical imaging frontier in biology, Nature Methods 7, 603 614 (2010). 4 H. F. Zhang, K. Maslov, G. Stoica, and L. H. V. Wang, Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging, Nature Biotechnology 24, 848 851 (2006). 5 K.Maslov, G.Stoica, andl.h.v.wang, Invivodark-fieldreflection-modephotoacoustic microscopy, Optics Letters 30, 625 627 (2005). 6 A. Agarwal, S. W. Huang, M. O Donnell, K. C. Day, M. Day, N. Kotov, and S. Ashkenazi, Targeted gold nanorod contrast agent for prostate cancer detection by photoacoustic imaging, Journal of Applied Physics 102 (2007). 7 P. C. Li, C. R. C. Wang, D. B. Shieh, C. W. Wei, C. K. Liao, C. Poe, S. Jhan, A. A. Ding, and Y. N. Wu, In vivo photoacoustic molecular imaging with simultaneous multiple selective targeting using antibody-conjugated gold nanorods, Optics Express 16, 18605 18615 (2008). 8 A. De La Zerda, C. Zavaleta, S. Keren, S. Vaithilingam, S. Bodapati, Z. Liu, J. Levi, B. R. Smith, T.-J. Ma, O. Oralkan, Z. Cheng, X. Chen, H. Dai, B. T. Khuri-Yakub, and S. S. Gambhir, Carbon nanotubes as photoacoustic molecular imaging agents in living mice, Nature Nanotechnology 3, 557 562 (2008). 9

9 S. Hu, K. Maslov, and L. H. V. Wang, Noninvasive label-free imaging of microhemodynamics by optical-resolution photoacoustic microscopy, Optics Express 17, 7688 7693 (2009). 10 J. A. Viator, G. Paltauf, S. L. Jacques, and S. A. Prahl, Design and testing of an endoscopic photoacoustic probe for determination of treatment depth after photodynamic therapy, Biomedical Optoacoustics Ii 2, 16 27 (2001). 11 S. Sethuraman, S. R. Aglyamov, J. H. Amirian, R. W. Smalling, and S. Y. Emelianov, Intravascular photoacoustic imaging using an ivus imaging catheter, Ieee Transactions on Ultrasonics Ferroelectrics and Frequency Control 54, 978 986 (2007). 12 J. M. Yang, K. Maslov, H. C. Yang, Q. F. Zhou, K. K. Shung, and L. H. V. Wang, Photoacoustic endoscopy, Optics Letters 34, 1591 1593 (2009). 13 K. Jansen, G. van Soest, and A. F. W. van der Steen, Intravascular photoacoustic imaging: A new tool for vulnerable plaque identification. Ultrasound in medicine and biology 40, 1037 1048 (2014). 14 P. Hajireza, W. Shi, and R. J. Zemp, Label-free in vivo fiber-based optical-resolution photoacoustic microscopy, Optics Letters 36, 4107 4109 (2011). 15 P. Hajireza, T. Harrison, A. Forbrich, and R. Zemp, Optical resolution photoacoustic microendoscopy with ultrasound-guided insertion and array system detection, Journal of Biomedical Optics 18 (2013). 16 I. N. Papadopoulos, S. Farahi, C. Moser, and D. Psaltis, Focusing and scanning light through a multimode optical fiber using digital phase conjugation, Optics Express 20, 10583 10590 (2012). 17 Y. Choi, C. Yoon, M. Kim, T. D. Yang, C. Fang-Yen, R. R. Dasari, K. J. Lee, and W. Choi, Scanner-free and wide-field endoscopic imaging by using a single multimode optical fiber, Physical Review Letters 109 (2012). 18 I. N. Papadopoulos, O. Simandoux, S. Farahi, J. P. Huignard, E. Bossy, D. Psaltis, and C. Moser, Optical-resolution photoacoustic microscopy by use of a multimode fiber, Applied Physics Letters 102 (2013). 19 P. N. T. Wells, Ultrasonic imaging of the human body, Reports on Progress in Physics 62, 671 722 (1999). 20 E. Z. Zhang and P. C. Beard, A miniature all-optical photoacoustic imaging probe, Photons Plus Ultrasound: Imaging and Sensing 2011 7899 (2011). 10

21 Y. Miida and Y. Matsuura, All-optical photoacoustic imaging system using fiber ultrasound probe and hollow optical fiber bundle, Optics Express 21, 22023 22033 (2013). 22 M. C. Teich and B. Saleh, Fundamentals of photonics, (Canada, Wiley Interscience, 1991) Chap. 9, Fiber Optics. 23 D.T. Blackstock, Fundamentals of physical acoustics, (John Wiley & Sons, 2000)Chap. 12, Waveguides. 24 P. Hajireza, W. Shi, and R. Zemp, Label-free in vivo grin-lens optical resolution photoacoustic micro-endoscopy, Laser Physics Letters 10 (2013). 25 O. Simandoux, Photoacoustic imaging: contributions to optical-resolution photoacoustic endoscopy and experimental investigation of thermal nonlinearity, Ph.D. thesis, University Paris Diderot, http://tel.archives-ouvertes.fr/tel-xxxx (2015). 11