Election Commission of India. Training on Use of Electronic Voting Machine

Similar documents
Electronic Voting Machine ( EVM) -preparedness for elections

Sub: Use of EVM in the elections- additional transparency measures

PRESENTATION ON. 20 May 2017

HALE SECURITY PET DOOR CAT GUARDIAN patent pending

PEARL - TILLER ASSEMBLY COMPLETE

XL³ 400 class II insulated distribution cabinets and cable compartments

XL³ 800 IP 55metal distribution cabinets, freestanding enclosures and cable compartments

GARNET STATIC SHOCK BARK COLLAR

Smart bark control collar BC-2. User manual

GARNET STATIC SHOCK BARK COLLAR

W360 Multifunction Tabber System Operator Guide

Upgrade KIT IV Operation Manual

Pixie-7P. Battery Connector Pixie-7P Fuse* Motor. 2.2 Attaching the Motor Leads. 1.0 Features of the Pixie-7P: Pixie-7P Batt Motor

YELLOW VIBRATION BARK COLLAR

KiwiSDR Quick Start Guide

DIGITUS Network Cabinet Unique Series, 600, 800 mm width - 600, 800, 1000, 1200 mm depth

7300 SPT 7302 SPT 7800 SPT 7802 D.T. SYSTEMS, INC.

AquaReef 200. Instruction Manual

Inter IKEA Systems B.V. (April 26, 2018) Canada FY18 Printed on recycled paper (Please recycle)

Fifteenth Annual Three Rivers District. Klondike Derby

OPERATION AND MAINTENANCE MANUAL

Calhoun County Fair and Livestock Show 2013 Junior Commercial Heifer Show and Sale Rule Book. Program Objectives

MGG Radio Controlled Hidden Fencing System for Dogs. Operator s Manual for Model no: HT-023

Seventeenth Annual Multnomah Service Area Klondike Derby

Our K9 LLC 616 Corporate Way Valley Cottage New York GARNET STATIC SHOCK BARK COLLAR USERS GUIDE

Quick Setup Guide Model 5134G

59-P-ID. Arcos Pendant Indirect /Direct. Ordering Guide. Key Features 59-P-ID. Fixture Type: Project Name: Quick Find litecontrol.

Applicable Tubing. Tubing material Tubing O.D. Specifications

CLUMBER SPANIEL CLUB OF AMERICA Top Ten Event Rules

S Fault Indicators. S.T.A.R. Type CR Faulted Circuit Indicator Installation Instructions. Contents PRODUCT INFORMATION

Radio Fence Plus Remote Trainer Owners Manual

Stainless Steel One-touch Fittings. Applicable Tubing. Tubing material Tubing O.D. Note 1) Soft nylon tubing is not compatible with water.

BUYING GUIDE ALGOT. Storage across the home. DESIGN Francis Cayouette

ELECTION COMMISSION OF INDIA I{IRVACIIAN SADAN, ASIIOKA ROAD, NEW DEI,HI-1lOOOl

ethercon solutions for multichannel audio, video, and mixed signal distribution* *: and more!

What do we do when the butterfly larvae arrive? How can we tell how much the larvae have grown?

PET DOOR. Deluxe Aluminium IMPORTANT! READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY AND KEEP FOR FUTURE REFERENCE. Product Codes: #1168, #1169, #1170

ORDINANCE NO. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF RIPON AS FOLLOWS:

MODLINK MSDD Front Panel Interfaces

PRESENTATION ON EVM & VVPAT. September, 2018

AGILITY REGULATIONS OF THE. Open Junior Agility Championships

AGILITY REGULATIONS OF THE. Open Junior Agility Championships

AGILITY OBSTACLE GUIDELINES

ASSEMBLY & INSTRUCTION MANUAL

Check the box after reviewing with your staff. DNA Collection Kit (Cheek Swab) Mailing a DNA Cheek Swab to BioPet. Waste Sample Collection

SUPER TRAINER EZT SERIES

Good Idea, Mother Nature!

SportHunter SD Operating Guide. Please read this entire guide before beginning

HerdMASTER 4 Tip Sheet CREATING ANIMALS AND SIRES

Little Love Puppy Pal

Smart Drive Electronic Washing Machine. Models GW503 GW603 GW703 GWC03 GWL03 GWM03 KE993 LW035 MW053 THL03

Please read this entire guide before beginning

User Manual EN: User Manual 1-32 DE: Bedienungsanleitung FR: Guide d utilisation NL: Handleiding

Getting Started. Instruction Manual

MGG Radio Controlled Hidden Fencing System for Dogs. Operator s Manual for Model no s: 023 and 023B

DOGSLIFE BEDS. wholesale products list 2018 SLEEPING I. 19 Osprey Drive, Jacobs Well. Qld. 4208

BARK CONTROL COLLAR Model NB-Pulse. User s guide

EPIC Industrial connectors

Foster Application. Facebook.com/furrytailendingscaninerescue us at Susan Daniele, President

Microchip Cat Flap. Instruction Manual Gebrauchsanweisung Hadleiding Notice D utilisation Brugervejledning

Installation Instructions

LOOX 12 V ESSENTIALS

Electronic Pet Fencing System W-227

Stainless One-touch Fittings. Applicable Tubing. Tubing material Tubing O.D. Note 1) Soft nylon tubing is not compatible with water.

ReproMatic & FluxxBreeder

pet containment product catalog petsentinelproducts.com

Getting Started. Device Overviews. Setting Up the Pro 550 System Before you can use the Pro 550 system, you must set up the devices.

ULTRA CLEAR SW AQUARIUM

Elite Outdoor Bark Control

PetSpy Advanced Dog Training System, Model M86N

Ultra Min No-Bark Training Collar Ultra Small Ultra Powerful Ultra Control

BUYING GUIDE PLATSA. Storage system

OPERATING GUIDE PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING

2. From where the latest Software Development Kit for the EVM can be downloaded?

BUYING GUIDE PLATSA. Storage system

U xafaiagy10258nzw BLUING TANK STAND SYSTEM INSTRUCTIONS WARNING SETTING UP THE BLUING STANDS HEIGHT OF BURNERS GAS LINES FINAL SETUP #

Accessories for Pigeon

2. From where the latest Software Development Kit for the EVM can be downloaded?

Examining and Medicating the Ears of Your Cat

DLS Sample Preparation Guide

Library. Order San Francisco Codes. Comprehensive Ordinance List. San Francisco, California

Laurelview Dog Kennel

KENNEL UNION OF SOUTHERN AFRICA. BASIC WORKING/BEHAVIOUR TEST (BH) (Begleithund) EFFECTIVE

The Doggie Lift Manual The Easiest Way to Cut Your Dog's Nails!

FCI LT LM UNDERGROUND

Design Guide. You can relax with a INSTALLATION QUALITY,CERTIFIED QTANK POLY RAINWATER TANKS. qtank.com.au

To the future host of a Vintage Thunderbird Club International convention:

USER S GUIDE DECLARATION «CE» DE CONFORMITE «EC» DECLARATION OF CONFORMITY. NUM AXES déclare que / declares that

-1- Please refer to the SAFETY INSTRUCTIONS portion of this manual

SAFETY BURNDY HYPRESS TM OPERATING & MAINTENANCE INSTRUCTIONS Y750BH 2004 FCI USA INC.

Quality Requirements Q3R Fit Check

Glassbrook Cemetery lots: Corner of Harrisburg and Glassbrook Road

Product Info Applications System Mgt References Competition

AVALANCHE FIELD TEST

SC500 53B. Model: SC B NIL. Part List US-English

BUYING GUIDE PLATSA. Storage system

Frequently Asked Questions

/ /03

PRE-ADOPTION FORM 10/1/16. Name of applicant: Date of birth: Home phone #: Work phone#: Cell# (s): Employer, Address, Position

Owner s Guide PCC-100 & PCC-200

Transcription:

Election Commission of India Training on Use of Electronic Voting Machine 2002 (ECIL MACHINES) EVM ECIL 2002 1

Description of EVM EVM ECIL 2002 2

Components of EVM Interconnecting Cable Control Unit Balloting Unit EVM ECIL 2002 3

Carrying Cases Carrying Case - Control Unit The Control Unit and Balloting Unit are packed separately in special carrying cases Carrying Case - Balloting Unit EVM ECIL 2002 4

Balloting Unit This is the Unit the voter operates to exercise his / her franchise The interconnecting cable is permanently attached to the Balloting Unit EVM ECIL 2002 5

Balloting Unit Details Ready Lamp Slide Switch Window Candidate s Button Candidate s Lamp Ballot Paper Screen EVM ECIL 2002 6

Balloting Unit Parts in Rear View Stand Door Connector Box Connector for Additional Balloting Unit Cable Clamp Box for Connector of Additional Balloting unit EVM ECIL 2002 7

Control Unit- Front View Power ON Lamp Display Section Busy Lamp Candidate Set Section Result Section Ballot Section EVM ECIL 2002 8

Control Unit Opening of Bottom Compartment Bottom Compartment Cover Press Latch to release Pull to open Cover Description EVM ECIL 2002 9

Control Unit - Bottom Compartment Power Switch Socket for Interconnecting Cable of Balloting unit Socket for connecting Auxiliary Control Unit. At present this HAS NO USE. DO NOT USE THIS SOCKET EVM ECIL 2002 10

Control Unit Display Section 4-Digit Display Panel Power ON Lamp Busy Lamp 2-Digit Display Panel EVM ECIL 2002 11

Control Unit Candidate Set Section Candidate set section inner door Candidate set section outer door Power Pack compartment Latch Candidate set button Hole to pass thread for sealing EVM ECIL 2002 12

Control Unit Result Section Close button Outer Door Result button Clear button Outer Door Hole to pass thread for sealing Inner compartment door Print button Inner latches Frame for 1 Paper seal EVM ECIL 2002 13

Control Unit Ballot Section Total button Ballot button EVM ECIL 2002 14

Preparation of EVM by Presiding Officers EVM ECIL 2002 15

ONE HOUR BEFORE COMMENCEMENT OF POLL Remove the Balloting Unit & Control Unit from their carrying cases Connect Balloting Unit to Control Unit Open rear compartment of Control Unit and Switch ON power EVM ECIL 2002 16

One hour before Commencement of Poll 4. Open Result section outer door and then the inner door 1 2 3 4 EVM ECIL 2002 17

One hour before Commencement of Poll 5. Press Clear button to show to the agents present that there are no votes polled EVM ECIL 2002 18

Mock Poll 1. Conduct mock poll for the benefit of polling agents 2. Press Ballot button on Control Unit and register one vote for any candidate in Balloting Unit 3. Repeat this process so as to record one vote for each candidate EVM ECIL 2002 19

Mock Poll 3. (Ensure that equal number of votes are polled for all candidates) 4. Close the mock poll by pressing Close button in Control Unit 5. press Ballot Button on Control Unit to show that NO vote can be recorded further after the close button is pressed EVM ECIL 2002 20

Mock Poll Display of the Result Press Result-I button and show the mock poll result EVM ECIL 2002 21

SEQUENCE OF OPERATION OF BUTTONS FOR CONDUCT OF MOCK POLL 1 BALLOT MOCK POLL 2 CLOSE 4 3 RESULT-I CLEAR SEAL EVM ECIL 2002 22

Control Unit Sealing for Actual Poll 1. After seeing result of mock poll, clear the machine by pressing Clear button 2. OPEN BACK COVER AND SWITCH OFF POWER. 3. Fix Green Paper Seal in the frame on the inner side of the door of the inner compartment of the Result section 4. Close the door of the inner compartment ensuring that the two open ends of the Green Paper Seal project outwards, as shown EVM ECIL 2002 23

Fixing Green Paper Seal Signature Presiding Officer should sign in full on white portion of Green paper seal Allow Candidates / agents present to sign if they so desire. AS FAR AS PRACTICABLE ALL SIGNATURES SHOULD BE IN THE MIDDLE OF THE GREEN PAPER SEAL Note down the Sl.Nos. of paper seals used in the Paper Seal Account in Form 17C EVM ECIL 2002 24

Sealing with Special Tag SIGNATURES 4. To seal the Inner Door of Result section, a Special Tag is devised 5. Put your signature on the back of the Special Tag SPECIAL TAG FRONT SIDE BACK SIDE 6. Allow Candidates / agents present to sign 7. Write the Control Unit ID No. on the front side of the Special Tag 8. Note the printed Sl.No. of Special Tag in the declaration to be made before commencement of poll EVM ECIL 2002 25

Sealing with Special Tag Read out the printed Sl.No. on the Special Tag and ask the Candidates / agents present to note down that number the door of the inner compartment be sealed by passing a twine thread through the two holes provided for the purpose on the left side of the inner door and tie a knot Then pass the lose ends of the twine thread through the hole (with metal ring) in the Special Tag and put a knot. Seal the knot on the Special Tag with the seal of the Presiding Officer EVM ECIL 2002 26

PLACING SEALED SPECIAL TAG OVER THE CLOSE BUTTON A hole of the size of Close button is cut in the middle of the Special Tag to fit exactly over the Close button After sealing, adjust the Special Tag over the Close button and fit the tag in the Close button compartment The Close button shall protrude through the aperture cut in the middle of the Tag. EVM ECIL 2002 27

Magnified view of Special Tag fixed in Close Button Compartment EVM ECIL 2002 28

FIXING OUTER STRIP SEAL-1 Close the Outer door of Result Section & allow Green Paper Seal to protrude out as shown First seal the outer door with an address tag EVM ECIL 2002 29

FIXING OUTER STRIP SEAL-2 Double fold the protruding lower end of the Green Paper Seal with the green side of the seal visible from outside EVM ECIL 2002 30

SPECIAL MATERIAL STRIP SEAL 1. This seal is 23.5 in length and 1 in width so as to drape it around the Control Unit 2. Each seal is printed with Unique Identity Number 3. There will be 4 pre-gummed portions at both the ends marked A, B C & D covered by strips of wax paper. The pre-gummed portions are marked in dark in the drawing below: A B LOWER SIDE D C UPPER SIDE 4. Before the start of the poll, the Result Section of the Control Unit is sealed from outside with the Strip Seal. 5. Each polling station shall be supplied with 4 Strips to allow wastage EVM ECIL 2002 31

FIXING OUTER STRIP SEAL-3 Keep the Strip Seal with the pre-gummed portion A near the base of the Lower fold of Green Paper Seal EVM ECIL 2002 32

FIXING OUTER STRIP SEAL-4 Remove the wax paper covering A and Press and paste the lower fold of the Green Paper Seal EVM ECIL 2002 33

FIXING OUTER STRIP SEAL-5 After pasting A, Remove the wax paper from pre-gummed portion B. Hold the upper fold of Green Paper Seal firmly and press the pregummed portion B firmly above this upper fold and paste EVM ECIL 2002 34

FIXING OUTER STRIP SEAL-6 After pasting B, the pre-gummed portion C will be on top. Remove the wax paper covering C. EVM ECIL 2002 35

FIXING OUTER STRIP SEAL-7 Press the end of the Green Paper Seal protruding from the top of the door onto C and paste them EVM ECIL 2002 36

FIXING OUTER STRIP SEAL-8 Take the Strip Seal round the Control Unit from left side just below the CLOSE button EVM ECIL 2002 37

FIXING OUTER STRIP SEAL-9 Bring the other end of the Strip Seal from right side to the top of the machine with pre-gummed portion D on top. Remove the wax paper over D and paste it on top of Green Paper Seal. A portion of D spills over the strip below CLOSE Button. Paste this also EVM ECIL 2002 38

FIXING OUTER STRIP SEAL-10 Now the Strip Seal is finally fixed and the Control Unit is ready to take real poll. EVM ECIL 2002 39

STRIP SEAL - IMPORTANT POINTS Allow the candidates/agents to note down the Unique Identity Number of the Strip Seal After sealing with Outer Paper Strip Seal, the Control Unit is ready for taking poll DO NOT remove this strip seal during or after the poll is over. Deliver the Control Unit with this seal intact to the RO after the poll Presiding Officer shall account for all Strip Seals issued - if any seal is damaged accidentally, use another one. Return to RO all unused and damaged seals. Now the Control Unit is ready for taking poll. EVM ECIL 2002 40

Procedure during Poll EVM ECIL 2002 41

Setting up the EVM in the Polling Station 1. Place the Balloting Unit in the voting compartment and the Control Unit on the table of the presiding / polling officer 2. Connect Balloting Unit to Control Unit 3. Take care to place the Cable in such a way that voters are not required to cross over it. 4. Open the bottom compartment and switch ON power 5. Close the bottom compartment of Control Unit 6. Press Total button to ensure that there are no votes cast before the actual poll EVM ECIL 2002 42

Key functions of Presiding Officers 1. Each voter shall be allowed to vote strictly in his / her own turn as per his/her entry in the Voters Register (Form 17A) 2. Frequently tally votes polled with the last entry in Voters Register 3. Ensure that no voter votes without signing the register & voters who have signed do not go away without voting 4. DO NOT ALLOW EITHER STILL OR VIDEO FILMING OF ACTUAL VOTING INSIDE VOTING COMPARTMENT EVM ECIL 2002 43

Voting Procedure After the voter has been identified and his/her signature / thumb impression obtained on Voters Register, Polling Officer shall issue Voter Slip to him/her showing his/her serial No. in Voters Register The officer in charge of Control Unit collects the voter slip and allows the voter to vote, strictly in his/her own turn He activates the Control Unit by pressing Ballot button and directs the voter to go to voting compartment for voting EVM ECIL 2002 44

Voting Procedure Inside voting compartment, voter is to press the blue Candidate button on the Balloting Unit against the name and symbol of the candidate of his / her choice On the candidate button being pressed, the red lamp will glow against the name and symbol of that candidate There will also be a beep sound heard to indicate that the vote has been cast and the Busy lamp goes off in the Control Unit This process is repeated for other voters till end of the poll Do not switch off the Control Unit during the poll EVM ECIL 2002 45

Procedure at Close of Poll EVM ECIL 2002 46

Closing of Poll 1. Remove the cap on Close button in the Control Unit and press the Close button as shown. Poll is closed.the Unit displays the total no. of candidates and the total no. of votes recorded. Fix the cap back in its place. 1. Note down the total votes recorded in Part I of Form 17C. 2. Press Total Button to verify the total at the close of the Poll. EVM ECIL 2002 47

Procedure at Close of Poll 4. Open the bottom compartment of Control Unit and switch OFF power and disconnect Balloting Unit cable 5. Pack the Control Unit (with the strip seal) and Balloting Unit in their carrying cases 6. Seal the carrying cases and fix address tags. Allow the candidates / Agents present to affix their seals, if they so desire 7. Deposit the sealed cases safely with the Returning Officer. EVM ECIL 2002 48

Important Tips for Presiding Officers Issue Remedy After Ballot button is activated in Control Unit, the last voter may refuse to vote Or After the poll was over, inadvertently Ballot button may have been pressed To stop the red Busy lamp in Control Unit, switch off the power. Busy lamp will stop glowing. Then, you may switch on power and close the poll. EVM ECIL 2002 49

EVM ECIL 2002 50