User s Guide. High Performance Linear Products SLOU119

Similar documents
TPS204xB/TPS205xB Current-Limited, Power-Distribution Switches data sheet (SLVS514)

Pixie-7P. Battery Connector Pixie-7P Fuse* Motor. 2.2 Attaching the Motor Leads. 1.0 Features of the Pixie-7P: Pixie-7P Batt Motor

OPERATING AND BASIC TRAINING GUIDE PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING

400 Yard Trainer GDT Product Manual

DURA PLASTIC PRODUCTS, INC.

Outdoor Bark Control

300 Yard Trainer GDT Product Manual

Your American Made Source

Operating Guide. PBC Rechargeable Bark Control Collar. Please read this entire guide before beginning.

MGL Avionics EFIS G2 and iefis. Guide to using the MGL RDAC CAN interface with the UL Power engines

Product Manual. PBC Bark Collar. Please read this entire Product Manual before beginning.

Table of Contents Operating Guide Training Guide

PetSpy Advanced Dog Training System, Model M86N

Elite Outdoor Bark Control

Please read this entire guide before beginning

NoBark 6. Operating Guide. Please read this entire guide before beginning

PetSpy Premium Dog Training Collar, Models M919-1/M919-2

COOPER POWER SERIES. S.T.A.R. Type ER faulted circuit indicator installation instructions. Fault Indicators MN320006EN

Quick Start ,3 Trouble Shooting ,5 Training

Elite Bark Control PBC operating and training guide. Big Dog Model Number. Little Dog Model Number

Laurelview Dog Kennel

Inductive Proximity Switches

OPERATING GUIDE PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING

2. From where the latest Software Development Kit for the EVM can be downloaded?

Half Moon Aquarium Kit

LP-NSM(L) Series. Features. Product Dimensions. Small size of Fast tripping resettable circuit protection

advanced bark control collar INSTRUCTION Manual

SportHunter SD Operating Guide. Please read this entire guide before beginning

2. From where the latest Software Development Kit for the EVM can be downloaded?

Puppy Sales Contract

Operating Guide. Please read this entire guide before beginning

Lioness Guidebook: Open Me to Get Started!

KiwiSDR Quick Start Guide

INNOTEK. Spray Bark Control. Operating Guide. Please read this entire guide before beginning.

7300 SPT 7302 SPT 7800 SPT 7802 D.T. SYSTEMS, INC.

COOPER POWER SERIES. S.T.A.R. PATHFINDER variable trip TPR faulted circuit indicator installation instructions. Fault indicators MN320003EN

Model Number HBK '(W) x 5'(L) x 5'(H) laurelview. dog kennel assembly instructions. Please read this entire guide before assembly

LP-NSM(L) Series. Features. Product Dimensions. Small size of Fast tripping resettable circuit protection

AT-215. Owner's Manual

SAFETY BURNDY HYPRESS TM OPERATING & MAINTENANCE INSTRUCTIONS Y750BH 2004 FCI USA INC.

Part Number: CAT6+ UTP PVC PATCH CORDS CAT6+ Patch Cord, UTP, PVC

Part Number: CAT6+ UTP PVC PATCH CORDS CAT6+ Patch Cord, UTP, PVC

advanced remote trainer INSTRUCTION Manual

S Fault Indicators. S.T.A.R. Type CR Faulted Circuit Indicator Installation Instructions. Contents PRODUCT INFORMATION

Vibratory Tumbler OWNER S MANUAL

Basic Bark Control Collar

Ultrasonic Bark Control Collar

SMARTKITTY SELFCLEANING LITTER BOX

PetSafe Deluxe Bark Control

F-CONNECTORS. Keystone Jack F-Connectors

AmpFlex Flexible Current Probes

BARK CONTROL COLLAR Model NB-Pulse. User s guide

Contract and Bill of Sale

EX3 Stepper-Motor Driven Electronic Expansion Valve Technical Data

Dances With Wolves Ranch, LLC Puppy Purchase Agreement and Limited Warranty

Single Port Modular Jacks

ISL55185 EVM Getting Started

QUICK-ACTING LONG-LASTING WATERPROOF READ ENTIRE LABEL AND ENCLOSED DIRECTIONS BEFORE EACH USE

ultrasmart receiver collar

Sold by:

Distributed by: Scotch-Brite Bristle Discs and Brushes. Patented abrasives. Safer operation and conformability in contoured areas.

Upgrade KIT IV Operation Manual

CONTRACT & HEALTH WARRANTY PET DOG

PetSafe Big Dog Spray Bark Control Collar

USA Product Label PARASTAR PLUS (45-88 LBS.) Novartis. (fipronil/cyphenothrin) 3 EASY-TO-USE APPLICATIONS. For dogs lbs.

288 Seymour River Place North Vancouver, BC V7H 1W6

Product Manual. ZAL Simply Clean Automatic Litter Box. Please read this entire Product Manual before beginning.

Client Information. Doggie Information

WARNING KEEP OUT OF REACH OF CHILDREN DO NOT USE ON CATS. Code: pvasmmd

Product Manual 100, 300, 600 AND 900 YARD REMOTE TRAINERS LITE STANDARD ADD-A-DOG

W360 Multifunction Tabber System Operator Guide

Artist/Gallery Terms and Conditions A Space For Art GmbH

Woonsocket Education Department REQUEST FOR PROPOSAL. For. Copiers Multi Function Device Lease

Product Manual. PDT Remote Spray Trainer. Please read this entire Product Manual before beginning.

This document is a preview generated by EVS

Bristle Discs and Brushes

PET DOOR. Deluxe Aluminium IMPORTANT! READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY AND KEEP FOR FUTURE REFERENCE. Product Codes: #1168, #1169, #1170

SUPER TRAINER EZT SERIES

Installation Instructions

4MONTHS FORDOGS MEDIUM DOG WARNING MEDIUM DOG LBS REPELS AND KILLS TICKS, FLEAS, & MOSOUITOS

HALE SECURITY PET DOOR CAT GUARDIAN patent pending

OPERATING GUIDE PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING

Whereas, Southern Lagotto Kennels, hereinafter called seller is the owner of a Lagotto Romagnolo further described as follows:

IEEE Std 592 Test Program using Current Cable Accessories and Installation Practices

PET SALES CONTRACT BREEDER. Street Address: th Concession. City: Schomberg BUYER. Street Address:

PAWSNCLAWS, INC. x BREEDER S SIGNATURE. x BUYER S SIGNATURE SALES AGREEMENT FOR A NON-BREEDING MALINOIS WITH LIMITED REGISTRATION

OPERATING GUIDE PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING

Getting Started. Device Overviews. Setting Up the Pro 550 System Before you can use the Pro 550 system, you must set up the devices.

Current shot records for the aforementioned canine are attached as Exhibit A and made a part of this contract.

Welcome to the World of Patpet.com. 620 Series. Remote Dog Training Collar

ANIMAL SERVICES AGREEMENT

Contents. Introduction...Page 3. Safety Instructions...Page 4. Before You Commence Installation...Page 5. Measuring Up...Page 6

RESCUE DOG VILLAGE, LLC Foster Contract

Table Of Contents. Important Safeguards...2. PT4 Transmitter Features...3. R7 and R9 Receiver Collar Features...5

Blue Malawi Operation Manual GB

Frequently Asked Questions

utca mother board for FMC ADC daughter cards

Delta Smart. Owner s Manual

ENGINEERING TEST SPECIFICATION

Brandenburg German Shepherds, Suli Domínguez, c/o N th Street, Menomonie, Wisconsin, Puppy Purchase Contract and Three-Year Health Guarantee:

Transcription:

User s Guide December 2001 High Performance Linear Products SLOU119

IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Mailing Address: Texas Instruments Post Office Box 655303 Dallas, Texas 75265 Copyright 2001, Texas Instruments Incorporated

EVM IMPORTANT NOTICE Texas Instruments (TI) provides the enclosed product(s) under the following conditions: This evaluation kit being sold by TI is intended for use for ENGINEERING DEVELOPMENT OR EVALUATION PURPOSES ONLY and is not considered by TI to be fit for commercial use. As such, the goods being provided may not be complete in terms of required design-, marketing-, and/or manufacturing-related protective considerations, including product safety measures typically found in the end product incorporating the goods. As a prototype, this product does not fall within the scope of the European Union directive on electromagnetic compatibility and therefore may not meet the technical requirements of the directive. Should this evaluation kit not meet the specifications indicated in the EVM User s Guide, the kit may be returned within 30 days from the date of delivery for a full refund. THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims arising from the handling or use of the goods. Please be aware that the products received may not be regulatory compliant or agency certified (FCC, UL, CE, etc.). Due to the open construction of the product, it is the user s responsibility to take any and all appropriate precautions with regard to electrostatic discharge. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or services described herein. Please read the EVM User s Guide and, specifically, the EVM Warnings and Restrictions notice in the EVM User s Guide prior to handling the product. This notice contains important safety information about temperatures and voltages. For further safety concerns, please contact the TI application engineer. Persons handling the product must have electronics training and observe good laboratory practice standards. No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or combination in which such TI products or services might be or are used. Mailing Address: Texas Instruments Post Office Box 655303 Dallas, Texas 75265 Copyright 2001, Texas Instruments Incorporated

EVM WARNINGS AND RESTRICTIONS It is important to operate this EVM within the maximum supply voltage of 6 V. Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are questions concerning the input range, please contact a TI field representative prior to connecting the input power. Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the EVM. Please consult the EVM User s Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative. During normal operation, some circuit components may have case temperatures greater than 85 C. The EVM is designed to operate properly with certain components above 25 C as long as the input and output ranges are maintained. These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors. These types of devices can be identified using the EVM schematic located in the EVM User s Guide. When placing measurement probes near these devices during operation, please be aware that these devices may be very warm to the touch. Mailing Address: Texas Instruments Post Office Box 655303 Dallas, Texas 75265 Copyright 2001, Texas Instruments Incorporated

Contents Contents 1 Introduction..................................................................... 1-1 1.1 Description................................................................ 1-2 1.2 TPA6017A2 EVM Specifications.............................................. 1-3 1.3 Related Documentation From Texas Instruments............................... 1-3 2 Operation....................................................................... 2-1 2.1 Quick Start List for Plug-n-Play Platform....................................... 2-2 2.2 Quick Start List for Stand-Alone Operation..................................... 2-4 3 Schematic, PCB Layers, and Parts List............................................ 3-1 3.1 TPS6017A2 EVM Schematic................................................. 3-2 3.2 TPA6017A2 EVM PCB Layers................................................ 3-3 3.3 TPA6017A2 EVM Parts List.................................................. 3-4 Figures 1 1 The TI TPA6017A2 Audio Power Amplifier EVM Top View......................... 1-2 1 2 The TI TPA6017A2 Audio Power Amplifier EVM Bottom View..................... 1-2 2 1 Module Preparation........................................................... 2-3 3 1 TPA6017A2 EVM Schematic................................................... 3-2 3 2 TPA6017A2 EVM Top Layer.................................................. 3-3 3 3 TPA6017A2 EVM Bottom Layer............................................... 3-3 Tables 2 1 Platform Jumper and Switch Settings for the TPA6017A2........................... 2-2 2 2 Gain Settings................................................................. 2-3 3 1 TPA6017A2 EVM Parts List.................................................... 3-4 v

vi

Chapter 1 Introduction The TPA6017A2 is a class AB 2-watts per channel stereo audio power evaluation module. Topic Page 1.1 Description................................................... 1-2 1.2 TPA6017A2 EVM Specifications................................ 1-3 1.3 Related Documentation From Texas Instruments................ 1-3 Introduction 1-1

Description 1.1 Description The TPA6017A2 audio power amplifier evaluation module is a 2-watt per channel class-ab stereo audio power amplifier complete with a small number of external components mounted on a circuit board that measures approximately 2-1/4 inches by 1-1/2 inches (Figure 1 1 and Figure 1 2). Figure 1 1. The TI TPA6017A2 Audio Power Amplifier EVM Top View Figure 1 2. The TI TPA6017A2 Audio Power Amplifier EVM Bottom View Single in-line header pins extend from the underside of the module to allow the EVM to be plugged into the TI plug-n-play audio amplifier platform (see literature number SLOU011), or to be directly wired into existing circuits and equipment when used stand-alone. 1-2

TPA6017A2 EVM Specifications The plug-n-play platform has room for a single TPA6017A2 evaluation module and is convenient for evaluating the TPA6017A2 device. The EVMs simply plug into the platform, which provides power to the modules and connects them to a versatile array of standard audio input and output jacks and connectors. There is nothing to build, nothing to solder, and nothing but the speakers included with the platform to hook up. 1.2 TPA6017A2 EVM Specifications Supply voltage range, V DD.............................. 4.5 V to 5.5 V Supply current, I DD......................................... 2 A max Continuous output power per channel, P O : 3 Ω, V DD = 5 V........... 2 W Minimum load impedance, R L.................................... 3 Ω 1.3 Related Documentation From Texas Instruments TI Plug-N-Play Audio Amplifier Evaluation Platform (literature number SLOU011) provides detailed information on the evaluation platform and its use with TI audio evaluation modules. TPA6017A2 2-W Stereo Audio Power Amplifier With Four Selectable Gain Settings (literature number SLOS386) is the data sheet for the TPA6017A2 audio amplifier integrated circuit. Introduction 1-3

1-4

Chapter 2 Operation This chapter describes the steps for use with plug-n-play platform and standalone operation. Topic Page 2.1 Quick Start List for Plug-n-Play Platform........................ 2-2 2.2 Quick Start List for Stand-Alone Operation...................... 2-4 Operation 2-1

Quick Start List for Plug-n-Play Platform 2.1 Quick Start List for Plug-n-Play Platform Follow these steps when using the TPA6017A2 EVM with the TI plug-n-play audio amplifier evaluation platform (see the platform user s guide, literature number SLOU011, for additional details). Numbered callouts for selected steps are shown in Figure 2 1. Platform Preparations 1) Ensure that all external power sources are set to OFF and that the platform power switch S1 is set to OFF. 2) Install a TPA6017A2 module in platform socket U2, taking care to align the module pins correctly. 3) Use switch S2 to select or bypass the signal conditioning EVM installed in U1. If no EVM is installed in U1, set this switch to OFF. 4) Set control signal polarity jumper JP8 to Lo. 5) Set jumper JP6 to select the Mute control input (this causes the TPA6017A2 to shut down if a plug is inserted into platform headphone jack J10). 6) If a headphone amplifier will be installed in U5, set headphone source switch S3 to U5. Table 2 1. Platform Jumper and Switch Settings for the TPA6017A2 EVM JP4 JP5 JP6 JP7 JP8 S2 S3 PNP Platform X ON Mute X Lo Note 2 U5 Notes: 1) ON = Jumper installed, OFF = Jumper NOT installed, X = Don t care 2) Set S2 to ON when signal conditioning board is installed in U1; set S2 to OFF when no signal conditioning board is installed. Power Supply 1) Select and connect the power supply (ensure power supply switch S1 is set to OFF) a) Connect an external regulated power supply set to 5 V to platform V DD power input connector J6. Observed marked polarity. OR b) Install a voltage regulator EVM (SLVP097 or equiv.) in platform socket U6. Connect a 7-V 12-V power source to a platform V CC power input J1 or J2 and jumper the appropriate power input (see platform user s guide). If using J1, J2, or B1, set S1 to ON to supply power to the EVM. Inputs and Outputs 1) Ensure that the audio signal source level is set to a minimum. 2) Connect the audio source to the left and right RCA phono jacks J3 and J5 or stereo miniature phone jack J4. 2-2

Quick Start List for Plug-n-Play Platform 3) Connect speakers to left and right RCA jacks J7 and J9 or to stripped wire speaker connectors J8. Evaluation Module Settings 1) Use jumpers J1 and J2 to set the gain of the TPA6017A2 amplifier (see Table 2 2 callout). Refer to Table 2 2 for gain settings. Table 2 2. Gain Settings GAIN0 (J1 jumper) GAIN1 (J2 jumper) Gain ON ON 6 db ON OFF 10 db OFF ON 15.6 db OFF OFF 21.6 db Note: ON = jumper installed; OFF = jumper NOT installed Figure 2 1. Module Preparation 2) Switch S1 is used to shut down the device. Push and hold S1 to put the device into shutdown mode. Releasing S1 returns the device to the active state. 1 Power Up 1) Verify correct voltage and input polarity and set the external power supply to ON. If V CC and an onboard regulator EVM are used to provide V DD, set the platform power switch S1 to ON. Platform LED2 should light indicating the presence of V DD, and the evaluation modules installed on the platform should begin operation. 2) Adjust the signal source level and gain setting jumpers, J1 and J2, as needed. Operation 2-3

Quick Start List for Stand-Alone Operation 2.2 Quick Start List for Stand-Alone Operation Follow these steps to use the TPA6017A2 EVM stand-alone or when connecting it into existing circuits or equipment. Connections to the EVM module header pins can be made via individual sockets, wire-wrapping, or soldering to the pins, either on the top or the bottom of the module circuit board. Power Supply 1) Ensure that all external power sources are set to OFF. 2) Connect an external regulated power supply set to 5 V to the module V DD and GND pins taking care to observe marked polarity. Inputs and Outputs 1) Ensure that the audio signal source level adjustments are set to minimum. 2) Connect the right and left positive audio source to the module RIN+ and LIN+ pins, respectively. Connect the right and left negative audio source to the module RIN and LIN pins, respectively. 3) If using single ended inputs, ground the LIN+ and RIN+ pins and connect the signal source to RIN and LIN. Evaluation Module Preparations 1) Use jumpers J1 and J2 to set the gain of the TPA6017A2 amplifier. Refer to Table 2 2 for gain settings. Control Inputs 1) SHUTDOWN: This pin is active LOW. A LOW on this pin (< 0.8 V) shuts down the amplifier; a HIGH (> 2 V) on this pin places the amplifier in the active state. Leaving this pin floating allows normal amplifier operation in the active state. Power Up 1) Verify correct voltage and input polarity and set the external power supply to ON. The EVM should begin operation. 2) Adjust the signal source level and gain setting jumpers, J1 and J2, as needed. 2-4

Chapter 3 Schematic, PCB Layers, and Parts List This chapter describes PCB layers, part list, and schematics. Topic Page 3.1 TPA6017A2 EVM Schematic.................................... 3-2 3.2 TPA6017A2 EVM PCB Layers.................................. 3-3 3.3 TPA6017A2 EVM Parts List..................................... 3-4 Schematic, PCB Layers, and Parts List 3-1

TPS6017A2 EVM Schematic 3.1 TPS6017A2 EVM Schematic Figure 3 1. TPA6017A2 EVM Schematic VDD GND J1 J2 R2 100 kω R1 100 kω 1 2 3 GND GAIN0 GAIN1 U1 TPA6017A2 GND SHUTDOWN ROUT+ 20 19 18 S1 VDD R3 100 kω SHUTDOWN ROUT+ LOUT+ 4 LOUT+ RIN 17 C1 0.47 µf RIN LIN VDD RIN+ LOUT LIN+ C6 0.47 µf C2 0.47 µf C3 0.47 µf C4 0.47 µf 5 6 7 8 9 LIN PVDD RIN+ LOUT LIN+ VDD PVDD ROUT GND NC 16 15 14 13 12 C7 0.47 µf C8 10 µf VDD ROUT 10 BYPASS GND 11 GND C5 0.47 µf 3-2

TPA6017A2 EVM PCB Layers 3.2 TPA6017A2 EVM PCB Layers Figure 3 2. TPA6017A2 EVM Top Layer Figure 3 3. TPA6017A2 EVM Bottom Layer Schematic, PCB Layers, and Parts List 3-3

TPA6017A2 EVM Parts List 3.3 TPA6017A2 EVM Parts List Table 3 1. TPA6017A2 EVM Parts List Reference Description Size C1, C2, C3, C4, C5, C6, C7 EVM QTY. Manufacturer/ Part Number Capacitor, 0.47 µf, 80%/ 20%, 16 V 0603 7 Panasonic/ ECJ 1VF1C474Z C8 Capacitor, 10 µf, 6.3 V A 1 Panasonic/ ECS TOJY106R R1, R2, R3 Resistor, 100 kω, 1/16 W, 5% 0603 3 Panasonic/ ERJ 3GEYJ104V S1 Switch, momentary pushbutton, 12 V, 50 ma SMD 1 Panasonic/ EVQ PPBA25 J1, J2 Header, 2 position 2 mm 2 Norcomp/ 2163 2 01 P2 P1, P2 Shunts 2 mm 2 3M / 953170 30 U1 Headers, 0.100 in centers, 1/2 in length 15 Samtec/ TSW 19 8 G S IC, TPA6017A2, 2W, Stereo audio power amplifier 20-pin TSSOP 1 TI/ TPA6017A2PWP PCB PCB, 2 layer, fits U2 on PnP 2.25 1.5 1 TI 3-4