Certified Reference Materials: TOC Conductivity Turbidity ph Custom

Similar documents
Application of Peristaltic Filling for Flexibility and Accuracy

CATS POWER CALIBRATOR BPP

Deptt of Pharma Science SGRR ITS Patel Nagar, Dehradun (UK)

THE IMPORTANCE OF QUALITY IN COMPOUNDED VETERINARY MEDICINES

This document is a preview generated by EVS

Fluoroquinolones ELISA KIT

Sensitive and selective analysis of fipronil residues in eggs using Thermo Scientific GC-MS/MS triple quadrupole technology

SPECTROPHOTOMETRIC ESTIMATION OF MELOXICAM IN BULK AND ITS PHARMACEUTICAL FORMULATIONS

Dr Nick Hill. Contents. Our mission is to develop products which educate and empower owners to provide a higher level of care for their pets.

Drinking Systems for Breeders & Pullets

a commitment to milk quality

Ultra-Fast Analysis of Contaminant Residue from Propolis by LC/MS/MS Using SPE

Guidelines for Laboratory Verification of Performance of the FilmArray BCID System

Determination of ofloxacin in bulk drug and pharmaceutical dosage form by high performance liquid chromatography method

American Veterinary Medical Association

Explanation of Down and Feather Tests (Includes References to International and Country Specific Standards)

VALIDATED RP-HPLC METHOD FOR THE SIMULTANEOUS DETERMINATION OF AMLODIPINE BESYLATE AND ATORVASTATIN CALCIUM IN BULK AND PHARMACEUTICAL FORMULATION

Kamepalli Sujana et al. / Journal of Pharmacy Research 2014,8(12), Available online through

OIE Quality Standard for Veterinary Laboratories

Pet-ID Microchips Reliable Compatible Durable Stable Traceable the ultimate microchip solution

SIMPLE U.V. SPECTROPHOTOMETRIC METHODS FOR THE ESTIMATION OF OFLOXACIN IN PHARMACEUTICAL FORMULATIONS

Rapid LC-MS/MS Method for the Analysis of Fipronil and Amitraz Insecticides and Associated Metabolites in Egg and Other Poultry Products

The OIE Relevant Standards and Guidelines for Vaccines

DETECTION OF INHIBITORY SUBSTANCES IN MILK

TOGETHER WE ACHIEVE THE BEST IN ANIMAL WELLBEING

Journal of Global Trends in Pharmaceutical Sciences

Complete Range of Watering Systems for Breeders & Pullets

DETERMINATION OF ACTIVE SUBSTANCES IN MULTICOMPONENT VETERINARY PREPARATIONS OF ANTIPARASITIC ACTION BY HPLC METHOD

OIE Standards for: Animal identification and traceability Antimicrobials

Multi-residue Screening of Veterinary Drugs (I) and (II) in Meat According to the Japan Positive List Using Cartridge-based SPE and LC-MS/MS

Veterinary Drug Detection in Pork and Milk

Stability of Tylosin in Honey Impact on Residue Analysis Don Noot, Tom Thompson

3. records of distribution for proteins and feeds are being kept to facilitate tracing throughout the animal feed and animal production chain.

AUDIT REPORT. Auditor(s) UFPAL

Quantification of Chloramphenicol in Chicken Using Xevo TQD with RADAR Technology

Determination of Benzimidazole Residues in Animal Tissue by Ultra High Performance Liquid Chromatography Tandem Mass Spectrometry

Public Assessment Report. Scientific discussion. Xiflodrop 5 mg/ml eye drops, solution. Moxifloxacin hydrochloride DK/H/2221/001/DC

Boyd Enterprises Advanced Aquarist Products Product Catalog

AMOXICILLIN AND CLAVULANIC ACID TABLETS Draft proposal for The International Pharmacopoeia (February 2018)

Poultry Watering Systems Catalogue

CALIFORNIA EGG LAWS & REGULATIONS: BACKGROUND INFORMATION

Cattle RFID. Partners

ULTRA CLEAR SW AQUARIUM

Determination of gentamicin and related impurities in gentamicin sulfate

Development and Validation of UV Spectrophotometric Area Under Curve (AUC) method for estimation of Pyrantel Pamoate in Bulk and Tablet Dosage Form

THE ADVANTAGES OF cgmp Manufactured Veterinary Drugs

Analysis of Multiclass Veterinary Drugs in Baby Food by Ultra Fast Chromatography with High Performance Triple Quadrupole Mass Spectrometry

Determination, Confirmation and Quantitation of Multi-Class Antibiotic Residues in Milk by UHPLC MS/MS

2003 CATALOG. PHONE: (804) FAX: (804) TOLL FREE:

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF AMLODIPINE BESYLATE AND IRBESARTAN

Quantification of Albendazole in Dewormer Formulations in the Kenyan market

Streptomycin Sulfate According to USP

Poultry Watering Systems Catalogue

METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF OFLOXACIN AND ORNIDAZOLE IN TABLET DOSAGE FORM BY RP-HPLC

PO. Vasan, Gandhinagar District, Gujarat, India, 3 Dean at Faculty of Pharmacy, Dharmsinh Desai University, Nadiad, Gujarat, India.

Check the box after reviewing with your staff. DNA Collection Kit (Cheek Swab) Mailing a DNA Cheek Swab to BioPet. Waste Sample Collection

RELIA-FLOW and STEADI-FLOW Nipple Drinking Systems and Accessories

My Simple Aquarium Smart Simple Advice from an Aquarium Maintenance Company

MEMORANDUM OF UNDERSTANDING (MOU)

Distributed by: Scotch-Brite Bristle Discs and Brushes. Patented abrasives. Safer operation and conformability in contoured areas.

PROPYLENE GLYCOL FREE MINOXIDIL TOPICAL FORMULATION FOR HAIR LOSS BASED ON PATENTED TECHNOLOGY

Tamboli Ashpak Mubarak et al. IRJP 2 (8)

Q: How does Petland ensure it purchases the best/healthiest puppies?

Veterinary Drugs Stakeholder Forum Meeting 1 - Summary

Quality of Veterinary Medicinal Products. How to ensure the quality of Veterinary Medicinal Products

Spectrophotometric Method for Simultaneous Estimation of Amlodipine Besylate in Pharmaceutical Formulation

Development and validation of a HPLC analytical assay method for amlodipine besylate tablets: A Potent Ca +2 channel blocker

NASH Analysis Lab. Report of the audit. Prepared by: NASH Analysis Lab. CEO: Ni Ni Win. Quality manager: AgnieszkaPaszkowska

Triline Pumps. Vacuum & Pressure Gas moving Engineers. Diaphragm Pumps EVM Series

Electromagnetic flowmeters. dg: NEW. Sensors MUT 2200 EL / MUT 2500 EL DS100-4-ENG 1/14

K9 Pipeline Leak Detection

Development and Validation of RP-HPLC Method for Determination of Related Substances of Medetomidine in Bulk Drug

FOR ANIMALS FOR HEALTH FOR YOU

ABSTRACT. Usharani N, Divya K and Ashrtiha VVS. Original Article

Internship/Seasonal Employment Opportunities 2018

S T O C K C A T A L O G Beer

Isocratic Reverse Phase High Performance Liquid Chromatographic Estimation of Ramipril and Amlodipine in Pharmaceutical Dosage Form

The OIE Relevant Standards and Guidelines for Veterinary Medicinal Products

Recognition of Export Controls and Certification Systems for Animals and Animal Products. Guidance for Competent Authorities of Exporting Countries

Effective Vaccine Management Initiative

ANNEXES. to the Proposal. for a REGULATION OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

VNA Level II Module 10: Hill s Resources Learning Objectives

Pet Food Donation of over $100,000 Comes to Colorful Colorado

They're not all the same: Why FDA approval of animal drugs matters

Webinar: Update and Briefing on Feed Rule November 13, 2008 FDA, Center for Veterinary Medicine Office of Surveillance & Compliance

Ohio State Board of Pharmacy Compliance in Veterinary Practice

American Sheep Industry Association, Inc.

Jake's Finer Foods Sabert Packaging Solutions Brochure

Welcome. We use the latest equipment and technology in our modern hatchery, enabling us to produce over 800,000 eggs per week.

ULTRAVIOL. UltraViol is a dynamically developing. We invite you to become our business partner.

Global Food Supply Chain Risks. Antibiotics and the emergence of antibiotic-resistant bacteria in the food chain

beta Catalogue 2018 Aquatic Environments

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF ALISKIREN AND AMLODIPINE IN TABLET DOSAGE FORM

Working for organic farming in Europe

Pharma Research Library. 2013, Vol. 1(1):19-29

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

New Model. Digital Mastitis Detector. Reduce of risk at early stage

Instruction Manual. 6. Connectors. Latest news and tips can be taken from Be flapscinated.

Providing Diagnostics to the International Veterinary Community

Microchipping Works: Best Practices

Transcription:

Certified Reference Materials: TOC Conductivity Turbidity ph Custom Life Sciences 2012

Dear Friends and Associates, I would like to share with you two significant milestones that we have recently experienced. The first involves designing and moving into a new facility in Golden, CO. Our business requires sizable amounts of lab and analytical space; something we had grown out of in our previous facility. We are excited that this new space has improved and increased our manufacturing and analytical capabilities, allowing us to positively impact the quality of our products and breadth of our offerings. The second milestone includes some significant anniversaries. In December 2006, a small company named ERA was purchased by Waters Technologies Corporation. At that time, ERA was celebrating 30 years in business and Waters 48. ERA was one of the largest proficiency testing and reference material suppliers and Waters a global leader in developing analytical instrumentation. With the publication of this catalog, we mark our fifth anniversary as part of the Waters organization and 35th year in business. What do we celebrate with these anniversaries? How has ERA changed? Well, although we are still ERA, we have proudly added our Waters affiliation and now you see us as ERA, A Waters Company. We have improved our website and online data tools by housing all of our servers in the Waters server facility. We have added staff to improve our ability to meet your needs with new products and personalized customer service. We have matured, expanded our laboratories and made significant operational improvements. With our anniversary milestones and new facility, we celebrate investment in our future together. Investments in all of the key areas that we believe will allow us to continuously improve our product quality, provide faster more complete customer service, and ultimately guarantee that our products exceed customer expectations. All of this was done with our sights set on the future. As ERA, A Waters Company, we are better positioned than ever to be your PT and CRM partner of choice long into the future. Regards, Carl Craig On behalf of the ERA family Carl Craig, Ph.D., President, ERA

ABOUT ERA International Quality Oversight... 4 Experience and Reach... 5 PRODUCTS System Suitability... 6-7 Total Organic Carbon (TOC) Reference Materials...8-21 Anatel Access 643 and A643a Bulk Calibration and Validation CRMs...10 Anatel TOC 600 Calibration and Validation CRMs...10 Anatel PAT700, A-1000 and AnaTOC Calibration and Validation CRMs...11 Sievers Models 400 and 500 Calibration and Validation CRMs...12 Sievers Models 800 and 900 CRMs and Consumables... 13-14 Analytik Jena and Lachat Calibration and Validation CRMs...15 OI Analytical Calibration and Validation CRMs...16 Shimadzu Calibration and Validation CRMs...17 Teledyne Tekmar CRMs and Consumables... 18-19 Thornton TOC Analyzer Calibration and Validation CRMs...20 Inorganic Carbon (IC) CRMs...21 Conductivity... 22-25 Conductivity Probe Validation Kits... 22-25 Low Level...24 Mid and High Level...25 Cleaning Validation... 26-29 Templates and Swabs...27 Coupons...28 Sampling Kits...29 Sample Vials and Containers... 30-31 Turbidity, ph, Reagents, Purified Water... 32-36 Turbidity CRMs...33 USP <467> Residual Solvents CRMs...34 Custom Services...34 High-Purity Reagents, ph...35 High-Purity USP-Purified Water...36 Master TOC CRM List by Manufacturer... 37-43 Index...44 Worldwide Distributors...45

About ERA International Quality Oversight Because quality is critical to you, it has to be critical for us. ERA s many ISO accreditations are an important part of what ensures the quality and accuracy of our products. Only with strict international oversight of processes are we able to continually provide the level of quality and consistency our customers need and demand. ISO 9001:2008 CERTIFICATE NO. 10551 ISO 9001:2008 Certification Certifies that ERA has documented procedures and training in the areas of customer service, R&D, operations and accounting. ISO/IEC 17025:2005 ACCREDITED ISO/IEC 17025:2005 Accredited Certifies that ERA is both proficient and consistent in the testing and confirmation of their product quality. CHEMICAL TESTING LABORATORY CERTIFICATE NO. 1539.02 ISO/IEC GUIDE 34:2009 ACCREDITED REFERENCE MATERIAL PRODUCER CERTIFICATE NO. 1539.03 ISO Guide 34:2009 Accredited Certifies that ERA s processes and procedures have been proven robust, ensuring consistently accurate reference standards. 4

Experience and Reach For 35 years ERA's Proficiency Testing (PT) programs and Certified Reference Materials (CRMs) have provided laboratories with the confidence that their data is valid and defensible. Partner with ERA and experience our dedication to your success. About ERA web Golden, Colorado (USA) Global Headquarters WWW.ERAQC.COM US Founded 1977 Degreed Chemists 35 Locations Golden, Colorado (USA) Global Headquarters Countries Served Over 150 Catherine Fuentes Production Technician Paul Battle Chemist Markets Served Pharmaceutical Clinical Environmental Food Safety Industrial Manchester, United Kingdom Product Lines Certified Reference Materials Calibration Standards Reagents Veronica Meketuk Chemist Proficiency Testing Programs Analyst Competency Testing P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 5

System Suitability Tests Total Organic Carbon (TOC) is a general test for the presence of organic compounds in water samples. For purified pharmaceutical waters, the United States Pharmacopeia (USP), European Pharmacopoeia (EP), Japanese Pharmacopoeia (JP), Chinese Pharmacopoeia (ChP) and Indian Pharmacopoeia (IP) all require TOC to be monitored and reported for pharmaceutical-grade waters. One ubiquitous test that is accepted globally as a means of confirming acceptable TOC analyzer performance, is the System Suitability Test, sometimes referred to as SST. While pharmacopeial bodies may have their own version of the test, the concept is the same: if an analyzer can successfully oxidize and compare two different sources of organic compounds according to individual acceptance criteria, it can be used to monitor TOC levels in pharmaceutical waters.

System Suitability Tests SSTs ERA offers test kits to comply with all major pharmacopeial TOC requirements for system suitability monitoring. Sievers USP <643>, EP 2.2.44, ChP, IP 2.4.30 JP 2.59 Sievers 800/900 Cat. #18000 Cat. #18038 Sievers 400 Cat. #18300 Sievers 500 (Standard IOS) Cat. #15105 Cat. #18038 Anatel USP <643>, EP 2.2.44, ChP, IP 2.4.30 JP 2.59 A643 Cat. #18400 Pat 700 Cat. #18402 Contact ERA Shimadzu USP <643>, EP 2.2.44, ChP, IP 2.4.30 JP 2.59 V-Series (chemical) Cat. #18004 Cat. #18038 V-Series (combustion) Cat. #18000 Contact ERA Tekmar, OI, AJ/Lachat USP <643>, EP 2.2.44, ChP, IP 2.4.30 JP 2.59 Fusion, Aurora, etc. Cat. #18004 Cat. #18038 All ERA system suitability kits come in both single-use as well as bulk varieties. Bulk standards for laboratory use come preserved and packaged in ultra-clean amber bottles with a 6-month expiration period from the day it is shipped. See our bulk system suitability sets throughout the catalog and call ERA for more information or to order. David Kilhefner Director of Operations As an organization, ERA is committed to being the best of the best with respect to our products and services. We maintain constant focus on perfection in developing and presenting solutions to our customers' needs. web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 7

Total Organic Carbon CRMs Since dedicating a full-time business unit to our Life Science customers, ERA has grown to become the premier manufacturer of TOC reference standards. With ISO Guide 34 and 17025 accreditations, we offer a comprehensive line of calibration, validation, and system suitability standards designed to verify your TOC instrument s performance. Regardless of manufacturer, ERA has TOC standards designed specifically for the instruments in your facility. Manufacturer Page Anatel 9-11 Analytik Jena and Lachat 15 OI Analytical 16 Shimadzu 17 Sievers 12-14 Teledyne Tekmar 18-19 Thornton 20

ANATEL ACCESS 643 AND 643a Calibration and Validation CRMs TOC Because most online TOC instruments are especially susceptible to interferences from background contamination, all of our CRMs are prepared using carefully controlled processes that are scrutinized under ERA s ISO Guide 34 accreditation. These manufacturing processes ensure that the results you receive from your TOC instrument reflect its true capabilities. The following individual and kitted CRMs are used for calibration and validation of Anatel on-line TOC analyzers. A643 Calibration Kit Cat. #19200 Set includes five vials, (2) Blanks, (1) 0.250 mg/l C NIST Sucrose, (1) 0.500 mg/l C NIST Sucrose, (1) 0.750 mg/l C NIST Sucrose. Replaces FG5017401. Individual CRMs for the A643 Calibration Blank 60 ml Cat. #13300 0.250 mg/l C NIST Sucrose 60 ml Cat. #13400 0.500 mg/l C NIST Sucrose 60 ml Cat. #13500 0.750 mg/l C NIST Sucrose 60 ml Cat. #13600 A643 Validation Kit Cat. #19210 Set includes ten vials, (2) Blanks, (1) 0.250 mg/l C NIST Sucrose, (1) 0.500 mg/l C NIST Sucrose, (1) 0.750 mg/l C NIST Sucrose, (1) 100 µs/cm Conductivity Std., (1) USP System Suitability Set. A643 Validation Control Kit Cat. #19220 Set includes three vials, (2) Blanks, (1) 0.500 mg/l C NIST Sucrose. Replaces FG5017501. A643 Validation Protocol Kit Cat. #19230 Set includes 38 vials, (10) Blanks, (3) 0.250 mg/l C NIST Sucrose, (5) 0.500 mg/l C NIST Sucrose, (3) 0.750 mg/l C NIST Sucrose, (1) 100 μs/cm Conductivity Std., (4) USP System Suitability Sets. Replaces reference materials portion of FG5017701 - lamp sold separately. USP System Suitability Set Cat. #18400 Set of four bottles includes (2) Reagent Waters Rw, (1) 0.500 mg/l C USP Sucrose Rs, and (1) 0.500 mg/l C USP 1,4-benzoquinone Rss. Replaces FG5017601. Conductivity Solution Kit Cat. #02610 Set includes one vial of 100 μs/cm KCI in water for calibrating conductivity probe on Anatel A643. Replaces FG5010401. See page 38 or contact ERA for additional concentrations and volumes System Suitability Set with Check Cat. #13390 Set of five bottles includes (2) Reagent Waters Rw, (1) 0.500 mg/l C USP Sucrose Rs, (1) 0.500 mg/l C USP 1,4-benzoquinone Rss and (1) 0.250 mg/l C NIST Sucrose as check. Miscellaneous Consumables Low TOC Sample Vial Kit Set includes one case of 68 pre-cleaned Low TOC glass vials, 50 ml with pre-cleaned septa and aluminum crimp cap. Use for grab samples to be analyzed on Anatel A643. Replaces FG5014801. Replacement UV Lamp Replacement UV Lamp for Anatel/HUA Model A643. Replaces FG6002601. Anatel Access A643a Cat. #25045 Cat. #20036A web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 9

TOC Anatel Access 643, A643a and TOC 600 Bulk Calibration and Validation CRMs While most Anatel products from ERA are ordered in ready-to-use (60 ml) containers for use with the Anatel Access 643 & 643a instruments, we also package them in large poly containers for pour-off use in special applications. Customers who use our bulk packaged CRMs rate them superior in stability and accuracy to other vendor s individually packaged standards. If you would like to try our bulk packaged CRMs to evaluate performance, convenience, and potential savings, please call us today to request a free sample. 10 Bulk Packaged Standards for Anatel 643 and TOC 600 125 ml Unpreserved TOC Calibration CRMs Calibration Blank Cat. #10019 0.250 mg/l C NIST Sucrose Cat. #10319 0.500 mg/l C NIST Sucrose Cat. #10619 0.750 mg/l C NIST Sucrose Cat. #10919 100 μs/cm Conductivity Calibration Standard Cat. #02600 250 ml Unpreserved TOC Calibration CRMs Calibration Blank Cat. #10031 0.250 mg/l C NIST Sucrose Cat. #10331 0.500 mg/l C NIST Sucrose Cat. #10631 0.750 mg/l C NIST Sucrose Cat. #10931 100 μs/cm Conductivity Calibration Standard Cat. #02250 500 ml Unpreserved TOC Calibration CRMs Calibration Blank Cat. #10120 0.250 mg/l C NIST Sucrose Cat. #10420 0.500 mg/l C NIST Sucrose Cat. #10720 0.750 mg/l C NIST Sucrose Cat. #11020 100 μs/cm Conductivity Calibration Standard Cat. #02500 Anatel TOC 600 Reference Standards TOC 600 Conductivity Cal/Ver at 100 µs/cm Cat. #02601 Validation Kit Cat. #19221 Set includes (1) Blank and (1) 0.500 mg/l C NIST Surcose. Validation Protocol Reagent Kit Set includes (29) 125 ml bottles, (1) Conductivity Solution Cat. #19231 Kit, (3) Calibration Standards Kit, (2) Validation Control Kit, (4) System Suitability Kit. Bulk USP System Suitability Sets for Anatel online TOCs 125 ml Cat. #18035 250 ml Cat. #18060 500 ml Cat. #18150 1 Liter Cat. #18245 TOC 600 USP System Suitability Set (125 ml) Miscellaneous Consumables 60 ml Low TOC Bottles Cat. # 18036 Set of three bottles includes (1) Reagent Water Rw,(1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. TOC 600 Calibration CRMs Kit (125 ml) Cat. # 19201 Set of four bottles includes (1) Blank, (1) 0.250 mg/l C NIST Sucrose, (1) 0.500 mg/l C NIST Sucrose, (1) 0.750 mg/l C NIST Sucrose. 60 ml HDPE Bottle for A643 (natural) Cat. #25030 60 ml HDPE Bottle for A643 (amber) Cat. #25033 60 ml HDPE Bottle for A643 (natural) - Pack of 25 Cat. #25031 60 ml HDPE Bottle for A643 (amber) - Pack of 25 Cat. #25034

Anatel PAT700, A-1000 and ANATOC Calibration and Validation CRMs TOC PAT700 CRMs are formulated specifically for the unique technology inherent in that instrument and are packaged ready to use in RFIDtagged bottles from ERA. ANATOC products are specially preserved and have an extended (60-day) expiration period. Like most of our products, these CRMs come in several bulk volumes. PAT700 Kits PAT700 System Suitability Kit Cat. #18402 Set of three bottles includes (1) Reagent Water Rw, (1) 0.500 mg/l C USP Sucrose Rs, (1) 0.500 mg/l C 1,4-benzoquinone Rss in 60 ml vials with RFID Tags. Replaces FG7018402. PAT700 Conductivity Solution Kit Cat. #02602 (1) 100 μs/cm KCl in 60 ml bottle with RFID Tag. Replaces FG7002602. PAT700 Calibration Standards Kit Cat. #19202 Set of four bottles includes (1) Blank, (1) 0.250 mg/l C NIST Sucrose, (1) 0.500 mg/l C NIST Sucrose, (1) 0.750 mg/l C NIST Sucrose in 60 ml bottles with RFID Tags. Replaces FG7019202. PAT700 Validation Control Kit Cat. #19222 Set of two bottles includes (1) Blank, (1) 0.500 mg/l C NIST Sucrose in 60 ml bottles with RFID Tags. Replaces FG7019222. PAT700 Validation Protocol Reagent Kit Cat. #19232 Set of 40 standards includes (14) Calibration Blanks, (5) Conductivity Solutions, (1) Validation Control Kit, (2) Calibration Standards Kits, (1) System Suitability Set, (1) Excursion w/ Validation Kit, (1) 0.250 mg/l C NIST Sucrose, (1) 0.750 mg/l C NIST Sucrose, (1) USP Reagent Water and (1) 0.500 mg/l C USP 1,4-benzoquinone. Includes two 60 ml excursion bottles; does not include NIST Traceable Resistor. Replaces FG7019232. PAT700 Excursion Kit Cat. #25100 Set of ten bottles includes 60 ml amber HDPE bottles with RFID Tags. Replaces FG7025100. PAT700 Excursion with Validation Kit Cat. #19250 Set of three bottles includes (1) Blank, (1) 0.500 mg/l C NIST Sucrose, (1) empty 60 ml amber HDPE bottle with RFID Tags. Replaces FG7019250. Replacement UV Lamp Replacement UV Lamp for Anatel/HUA Model PAT700. Cat. #20037 Individual Calibration and Validation CRMs for A-1000 Calibration Blank (1 Liter) Cat. #10211 0.250 mg/l C NIST Sucrose (1 Liter) Cat. #10511 0.500 mg/l C NIST Sucrose (1 Liter) Cat. #10811 0.750 mg/l C NIST Sucrose (1 Liter) Cat. #11111 USP System Suitability Set (1 Liter) Cat. #19030 See page 38 or contact us for additional concentrations and volumes. ANATOC Validation Set Cat. #19100 Set of six bottles includes (1) 250 ml TOC Blank, (1) 125 ml 0.500 mg/l C KHP, (1) 250 ml 1.00 mg/l C KHP, and (1) 125 ml USP System Suitability Set containing (1) Reagent Water Rw, (1) 0.500 mg/l C USP Sucrose Rs and (1) 0.500 mg/l C USP 1,4-benzoquinone Rss. AnaTOC Bulk CRMs (6-month expiration) 125 ml Preserved TOC Calibration CRMs TOC Water Blank Cat. #10015 0.250 mg/l C NIST KHP Cat. #11720 0.500 mg/l C NIST KHP Cat. #11730 1.00 mg/l C NIST KHP Cat. #11810 USP System Suitability Set Cat. #18025 250 ml Preserved TOC Calibration CRMs TOC Water Blank Cat. #10025 0.250 mg/l C NIST KHP Cat. #11721 0.500 mg/l C NIST KHP Cat. #11735 1.00 mg/l C NIST KHP Cat. #11820 USP System Suitability Set Cat. #18050 500 ml Preserved TOC Calibration CRMs TOC Water Blank Cat. #10100 0.250 mg/l C NIST KHP Cat. #11722 0.500 mg/l C NIST KHP Cat. #11750 1.00 mg/l C NIST KHP Cat. #11900 1000 mg/l C NIST KHP Cat. #13299 USP System Suitability Set Cat. #18100 Anatel PAT700 web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 11

TOC Sievers Models 400 and 500 Calibration and Validation CRMs TOC instruments that rely heavily on conductivity as part of their analysis technique must utilize specially prepared reference standards as part of their calibrations and system suitability tests. ERA s carefully designed preparations eliminate all extraneous sources of conductivity and TOC during the production process. All reference standards are available in both single-use and bulk varieties for your convenience. Calibration Set Cat. #14101 Sievers Model 400 Calibration Set includes (1) calibration blank, (1) 1.25 mg/l C NIST Sucrose, (1) 25 µs/cm conductivity. Individual Use Standards 30 ml TOC Calibration CRMs Calibration Blank Cat. #13700 1.25 mg/l C NIST Sucrose Cat. #14100 Conductivity CRMs 25 μs/cm Conductivity Calibration Standard Cat. #02700 Bulk Packaged CRMs 125 ml TOC Calibration CRMs Calibration Blank Cat. #10020 1.25 mg/l C NIST Sucrose Calibration Standard Cat. #11520 25 μs/cm Conductivity Calibration Standard Cat. #01400 250 ml TOC Calibration CRMs Calibration Blank Cat. #10030 1.25 mg/l C NIST Sucrose Calibration Standard Cat. #11530 25 μs/cm Conductivity Calibration Standard Cat. #01350 USP System Suitability Sets Set of three bottles includes (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. 30 ml Cat. #18300 125 ml Cat. #18030 250 ml Cat. #18055 500 ml Cat. #18140 1 Liter Cat. # 18240 Sievers 500 RL (Standard IOS) Single-Use CRMs System Suitability Set (Replaces CSTD 74403) Cat. #15105 Single-Point Cal Set (Replaces CSTD 74401) Cat. #15100 Single-Point Cal/Veri Set (Replaces CSTD 74612) Cat. #15101 Multi-Point Cal Set (Replaces CSTD 74614) Cat. #15102 Multi-Point Cal/Veri Set (Replaces CSTD 74616) Cat. #15103 Acc/Prec/Veri Set (Replaces CSTD 74402) Cat. #15104 Linearity Set (Replaces CSTD74406) Cat. #15106 Single-Point Validation Set (Replaces CSTD 74613) Cat. #15107 Multi-Point Validation Set (Replaces CSTD 74615) Cat. #15108 Single-Point Cal Set - TOC Only (Replaces CSTD 74405) Cat. #15109 Acc/Prec/Veri Set - TOC Only (Replaces CSTD 74407) Cat. #15110 Single-Point Cal/Veri Set - TOC Only (Replaces CSTD 74622) Cat. #15111 Multi-Point Cal Set - TOC Only (Replaces CSTD 74624) Cat. #15112 Multi-Point Cal/Veri Set - TOC Only (Replaces CSTD 74626) Cat. #15113 See page 39 or contact us for additional concentrations and volumes. 500 ml TOC Calibration CRMs Calibration Blank Cat. #10110 1.25 mg/l C NIST Sucrose Calibration Standard Cat. #11601 25 μs/cm Conductivity Calibration Standard Cat. #01300 Miscellaneous Consumables Replacement UV Lamps Replacement UV Lamp for Sievers Model 400 Cat. #20040 Replacement UV Lamp for Sievers Model 500 Cat. #20045 Filters and Tubing 60 Micron in-line Stainless Filter Cat. #25035 Fan filter for Sievers Model 400 Cat. #25040 Replacement pump-tubing for Sievers Model 400 Cat. #20055 30 ml Poly Vials 30 ml polymer vials for use with Sievers Model 400 TOC analyzers. Cat. #25015 12

Sievers Models 800 and 900 Calibration and Validation CRMs TOC ERA manufactures all of our own products and provides conforming certificates of analysis with each CRM under our ISO Guide 34 accreditation. Try ERA calibration and validation reference standards designed specifically for use with Sievers brand Model 800 and 900 TOC analyzers. USP System Suitability Set Cat. #18000 Set of three 40 ml vials includes (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. Replaces Sievers Part STD 31004. Sievers Model 800 Autosampler Calibration Set Cat. #19500 Set includes twelve 40 ml vials, (4) blanks, (4) 25.0 mg/l C NIST KHP, (4) 25.0 mg/l IC NIST NaHCO 3. Replaces Sievers Part STD 31002. See pages 40-41 for individual standards. Sievers Model 800 Grab Mode Calibration Set Cat. #19510 Set includes six 40 ml vials, (2) blanks, (2) 25.0 mg/l C NIST KHP, (2) 25.0 mg/l IC NIST NaHCO 3. Replaces Sievers Part STD 31001. Sievers 800 and 900 Linearity Set Cat. #19515 Set includes four 40 ml vials, (1) blank, (1) 0.250 mg/l C NIST KHP, (1) 0.500 mg/l C NIST KHP, (1) 0.750 mg/l C KHP. Replaces Sievers Part STD 31012. Bulk Preserved USP System Suitability Sets These bulk standards come preserved and packaged in ultra-clean amber bottles for use with Sievers Model 800 and 900 TOC analyzers. Each bulk reference standard has a 6-month expiration period from the day it is shipped. 125 ml Cat. #18025 250 ml Cat. #18050 500 ml Cat. #18100 1 Liter Cat. #18200 Inorganic Carbon Standards 0.500 mg/l IC from NaHCO 3-40 ml Cat. #15990 1.00 mg/l IC from NaHCO 3-40 ml Cat. #16000 5.00 mg/l IC from NaHCO 3-40 ml Cat. #16300 10.0 mg/l IC from NaHCO 3-40 ml Cat. #16600 25.0 mg/l IC from NaHCO 3-40 ml Cat. #16900 50.0 mg/l IC from NaHCO 3-40 ml Cat. #17130 100 mg/l IC from NaHCO 3-40 ml Cat. #17150 Sievers Model 800 Low Level Validation Set Cat. #19520 Set includes 37 vials, (10) blanks, (4) 25.0 mg/l C NIST KHP, (4) 25.0 mg/l IC NIST NaHCO 3, (2) 0.250 mg/l C NIST KHP, (9) 0.500 mg/l C NIST KHP, (2) 0.750 mg/l C NIST KHP, and (2) USP System Suitability Sets. Replaces Sievers Part STD 38101. web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU See page 21 for a complete list of Inorganic Carbon CRMs. 13

TOC Sievers Models 800 and 900 Calibration and Validation CRMs Unlike most instrument companies, ERA manufactures all of our own products and provides conforming certificates of analysis with each CRM under our ISO Guide 34 accreditation. Try ERA calibration and validation reference standards designed specifically for use with Sievers brand Model 800 and 900 TOC analyzers. Sievers Model 900 Cal & VER Set Cat. # 19600 Set includes six 40 ml vials, (2) blank, (2) 1.0 mg/l IC NIST NaHCO 3, (1) 1.0 mg/l C NIST KHP and (1) 1.00 mg/l C NIST Sucrose. Replaces Sievers Part STD 90016. Sievers Model 900 Multi-Point Calibration Set Cat. # 19610 Set includes eleven 40 ml vials, (1) blank, (1) each of 1.00, 5.00, 10.0, 25.0 and 50.0 mg/l C NIST KHP, (1) each of 1.00, 5.00, 10.0, 25.0 and 50.0 mg/l IC NIST NaHCO 3. Replaces Sievers Part STD 90000. Sievers Model 900 Autoreagents Calibration Set Cat. # 19611 Set includes four 40 ml vials, (1) blank, (1) 25.0 mg/l C NIST KHP, (1) 25 mg/l IC NIST NaHCO 3, (1) 50.0 mg/l C from Nicotinamide. Replaces Sievers Part STD 90036. Ultra Low-Level TOC CRMs Kit Cat. #14200 Set includes twelve 40 ml vials, (3) TOC Water Blanks, (1) each of 0.050, 0.060, 0.070, 0.080, 0.090, 0.100, 0.250, 0.500 and 1.00 mg/l C from NIST KHP. Reagents 150 ml H 3 PO 4 Reagent Cartridge for Sievers 800/900 150 ml (NH 4 ) 2 S 2 O 8 Reagent Cartridge for Sievers 800/900 300 ml H 3 PO 4 Reagent Cartridge for Sievers 800/900 300 ml (NH 4 ) 2 S 2 O 8 Reagent Cartridge for Sievers 800/900 Cat. #21000 Cat. #21005 Cat. #21001 Cat. #21006 Sievers Model 900 Miscellaneous Consumables Replacement UV Lamps Replacement UV Lamp for Sievers Model 400 Cat. #20040 Replacement UV Lamp for Sievers Model 500 Cat. #20045 Filters, Tubing and Cartridges 60 Micron in-line Stainless Filter Cat. #25035 Fan filter for Sievers Model 800 Cat. #25040 Replacement pump-tubing for Sievers Model 800 Cat. #20050 Replacement pump-tubing for Sievers Model 900 Cat. #20060 Sievers 900 replacement resin cartridge Cat. #20038 40 ml Low TOC Vials (80/cs) Low TOC vials certified <10 ppb TOC Cat. #25025 See page 31 for more information on vials. 14

Analytik Jena and Lachat Calibration and Validation CRMs TOC Leaders in the development of reliable composite parameter and elemental systems, Analytik Jena (AJ) and Lachat analyzers satisfy many of the demands of today s diverse modern laboratory. ERA carries all of the major validation and calibration sets for AJ and Lachat Total Organic Carbon instruments. USP System Suitability Set (40 ml) Bulk Preserved USP System Suitability Sets Set of three vials includes (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. For AJ multi N/C pharma HS and IL550 Cat # 18000 For AJ multi N/C UV HS and IL500 Cat # 18004 USP System Suitability Set (250 ml) Set includes (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. For AJ multi N/C pharma HS and IL550 Cat # 18050 For AJ multi N/C UV HS and IL500 Cat # 18049 Full TOC Calibration Kit (250 ml) Set includes eight 250 ml amber bottles, (1) Water blank, (1) 1.00 mg/l C NIST KHP, (1) 2.50 mg/l C NIST KHP, (1) 5.00 mg/l C NIST KHP, (1) 10.0 mg/l C NIST KHP, (1) 25.0 mg/l C NIST KHP, (1) 50.0 mg/l C NIST KHP, (1) 100 mg/l C NIST KHP. For AJ multi N/C 2100/3100 and IL550 Cat # 19970 For AJ multi N/C UV HS and IL500 Cat # 19971 Limited TOC Calibration Kit (40 ml) Set includes (1) Reagent Water Blank, (1) 0.600 mg/l C USP Sucrose. For AJ multi N/C pharma HS and IL550 Cat # 19980 For AJ multi N/C UV HS and IL500 Cat # 18981 Limited TOC Calibration Kit (250 ml) Set includes (1) Reagent Water Blank, (1) 0.600 mg/l C NIST Sucrose. For AJ multi N/C pharma HS and IL550 Cat # 19985 For AJ multi N/C UV HS and IL500 Cat # 19986 These bulk standards come packaged in ultra-clean amber bottles for use with AJ/ Lachat TOC analyzers. Each standard has a 6-month expiration period from the day it is shipped. Each set contains (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. 125 ml Cat # 18024 250 ml Cat # 18049 500 ml Cat # 18104 1 Liter Cat # 18204 Cleaning Validation Kit (40 ml) Set includes five 40 ml vials, (1) Water blank, (1) 0.250 mg/l C NIST Sucrose, (1) 0.500 mg/l C NIST Sucrose, (1) 0.750 mg/l C NIST Sucrose, (1) 1.00 mg/l C NIST Sucrose. For AJ multi N/C pharma HS and IL550 Cat # 19900 For AJ multi N/C UV HS and IL500 Cat # 19901 Cleaning Validation Kit (250 ml) Set includes five 250 ml amber bottles, (1) Water blank, (1) 0.250 mg/l C NIST Sucrose, (1) 0.500 mg/l C NIST Sucrose, (1) 0.750 mg/l C NIST Sucrose, (1) 1.00 mg/l C NIST Sucrose. For AJ multi N/C pharma HS and IL550 Cat # 19910 For AJ multi N/C UV HS and IL500 Cat # 19911 Analytik Jena multi N/C pharma HS web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU See page 21 for a complete list of Inorganic Carbon CRMs. 15

TOC OI Analytical Calibration and Validation CRMs OI Analytical has been manufacturing TOC analyzers for ultra-low carbon analysis for more than 25 years, and has been contracted to design water quality monitoring instrumentation that currently resides on the international space station. The products below are commonly purchased for use with OI Analytical TOC instruments, including the very popular Aurora model. Individual CRMs for Calibration or Verification TOC/IC Calibration Blank 40 ml Cat. #10001 TOC/IC Calibration Blank 125 ml Cat. #10016 0.500 mg/l C NIST KHP 40 ml Cat. #11726 0.500 mg/l C NIST KHP 125 ml Cat. #11731 1.00 mg/l C NIST KHP 40 ml Cat. #11801 1.00 mg/l C NIST KHP 125 ml Cat. #11811 5.00 mg/l C NIST KHP 40 ml Cat. #12401 5.00 mg/l C NIST KHP 125 ml Cat. #12411 10.0 mg/l C NIST KHP 40 ml Cat. #12701 10.0 mg/l C NIST KHP 125 ml Cat. #12711 25.0 mg/l C NIST KHP 40 ml Cat. #13001 25.0 mg/l C NIST KHP 125 ml Cat. #13021 50.0 mg/l C NIST KHP 40 ml Cat. #13224 50.0 mg/l C NIST KHP 125 ml Cat. #13227 Rw-Reagent Water USP 40 ml Cat. #18006 Rs-0.500 mg/l C USP Sucrose RS 40 ml Cat. #18007 Rss-0.500 mg/l C USP 1,4-benzoquinone 40 ml Cat. #18008 Rw-Reagent Water USP 125 ml Cat. #18029 Rs-0.500 mg/l C USP Sucrose RS 125 ml Cat. #18031 Rss-0.500 mg/l C USP 1,4-benzoquinone 125 ml Cat. #18032 See page 42 or contact us for additional concentrations and volumes. OI Aurora Acid and Persulfate Reagents Phosphoric Acid Reagent - 1 Liter Cat. #21016 Persulfate Oxidizer Reagent - 1 Liter Cat. #21017 Phosphoric Acid Reagent - 2 Liter Cat. #21018 Persulfate Oxidizer Reagent - 2 Liter Cat. #21019 OI Analytical TOC Validation Set Aurora Cat. #19007 Set of 19 vials includes (6) Water blank, (1) 0.500 mg/l C NIST KHP, (3) 1.00 mg/l C NIST KHP, (1) 5.00 mg/l C NIST KHP, (1) 10.0 mg/l C NIST KHP, (1) 25.0 mg/l C NIST KHP, (1) 5.00 mg/l C NIST KHP/50.0 mg/l IC NaHCO 3, (4) 0.500 mg/l C from USP Sucrose, (1) 0.500 mg/l C from USP 1,4-benzoquinone. Ultra Low-Level TOC CRMs Kit Cat. #14203 Set of 12 vials includes (3) TOC Water Blanks, (1) each of 0.050, 0.060, 0.070, 0.080, 0.090, 0.100, 0.250, 0.500 and 1.00 mg/l C from NIST KHP. USP System Suitability Set (40 ml) Cat. #18004 Set of three vials includes (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. Bulk Preserved USP System Suitability Sets These bulk standards come packaged in ultra-clean amber bottles for use with OI Analytical TOC analyzers. Each standard has a six month expiration period from the day it is shipped. Each set contains (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. 125 ml Cat. #18024 250 ml Cat. #18049 500 ml Cat. #18104 1 Liter Cat. #18204 Miscellaneous Consumables 40 ml Low TOC Vials (80/cs) Low TOC vials certified <10 ppb TOC Cat. #25025 See page 31 for more information on vials. 16 See page 21 for a complete list of Inorganic Carbon CRMs.

Shimadzu Calibration and Validation CRMs TOC Shimadzu has a long history in TOC analysis, which has evolved to include a product line of more than half a dozen wet chemical oxidation/ndir and Combustion catalytic oxidation/ndir instruments. The products below are commonly purchased for use with Shimadzu V-series TOC instruments. Please specify at time of order whether you have a chemical or combustion Shimadzu TOC. USP System Suitability Sets Set of three vials includes (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. 40 ml Cat. #18000 Bulk Preserved USP System Suitability Sets These bulk system suitability sets come packaged in ultra-clean amber bottles for use with Shimadzu TOC analyzers. Each standard has a six month expiration period from the day it is shipped. Each set contains (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. 125 ml Cat. #18024 250 ml Cat. #18049 500 ml Cat. #18104 1 Liter Cat. #18204 Individual CRMs for Calibration or Verification TOC/IC Calibration Blank 40 ml Cat. #10001 0.100 mg/l C NIST KHP 40 ml Cat. #11673 0.250 mg/l C NIST KHP 40 ml Cat. #11678 0.500 mg/l C NIST KHP 40 ml Cat. #11726 0.750 mg/l C NIST KHP 40 ml Cat. #11781 1.00 mg/l C NIST KHP 40 ml Cat. #11801 5.00 mg/l C NIST KHP 40 ml Cat. #12401 10.0 mg/l C NIST KHP 40 ml Cat. #12701 25.0 mg/l C NIST KHP 40 ml Cat. #13001 50.0 mg/l C NIST KHP 40 ml Cat. #13224 Please see page 42 for additional concentrations and volumes. Shimadzu TOC TCs TOC-V Validation Kit Shimadzu TOC VWs Cat. #11002 Set includes three 125 ml bottles, (1) Blank, (2) 100.0 mg/l C NIST KHP. TOC-V HS Validation Kit Cat. #11003 Set includes three 125 ml bottles, (1) Blank, (2) 10.0 mg/l C NIST KHP. TOC-V Wet Chem Validation Kit Cat. #11004 Set includes nine 40 ml vials, (3) Blank, (2) 0.500 mg/l C NIST KHP, (4) 1.00 mg/l C NIST KHP. TOC-V Multi Calibration Kit Cat. #11005 Set includes ten 40 ml vials, (2) Blank, (2) 0.100 mg/l C NIST KHP, (2) 0.250 mg/l C NIST KHP, (2) 0.500 mg/l C NIST KHP, (1) 0.750 mg/l C NIST KHP, (1) 1.00 mg/l C NIST KHP. Acid and Persulfate Reagents Phosphoric Acid Reagent - 1 Liter Cat. #21016 Persulfate Oxidizer Reagent - 1 Liter Cat. #21017 Phosphoric Acid Reagent - 2 Liter Cat. #21018 Persulfate Oxidizer Reagent - 2 Liter Cat. #21019 web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU See page 21 for a complete list of Inorganic Carbon CRMs. 17

TOC Teledyne Tekmar CRMs and Consumables With roots that can be traced back to the Dohrmann company founded in 1960 by Bruce Dohrmann, Teledyne Tekmar marked nearly 35 years as a pioneer in the development of TOC technologies when it released the TOC Fusion in 2005. ERA offers a comprehensive suite of calibration and validation CRMs designed specifically for Tekmar TOC instruments. Individual CRMs for Calibration or Verification TOC/IC Calibration Blank 40 ml Cat. #10001 TOC/IC Calibration Blank 125 ml Cat. #10016 0.500 mg/l C from NIST KHP 40 ml Cat. #11726 0.500 mg/l C from NIST KHP 125 ml Cat. #11731 1.00 mg/l C from NIST KHP 40 ml Cat. #11801 1.00 mg/l C from NIST KHP 125 ml Cat. #11811 5.00 mg/l C from NIST KHP 40 ml Cat. #12401 5.00 mg/l C from NIST KHP 125 ml Cat. #12411 10.0 mg/l C from NIST KHP 40 ml Cat. #12701 10.0 mg/l C from NIST KHP 125 ml Cat. #12711 25.0 mg/l C from NIST KHP 40 ml Cat. #13001 25.0 mg/l C from NIST KHP 125 ml Cat. #13021 50.0 mg/l C from NIST KHP 40 ml Cat. #13224 50.0 mg/l C from NIST KHP 125 ml Cat. #13227 Rw-Reagent Water USP 40 ml Cat. #18006 Rs-0.500 mg/l C from USP Sucrose RS 40 ml Cat. #18007 Rss-0.500 mg/l C from USP 1,4-benzoquinone 40 ml Cat. #18008 USP System Suitability Set 125 ml Cat. #18024 Rw-Reagent Water USP 125 ml Cat. #18029 Rs-0.500 mg/l C from USP Sucrose RS 125 ml Cat. #18031 Rss-0.500 mg/l C from USP 1,4-benzoquinone 125 ml Cat. #18032 See page 42 for additional concentrations and volumes. Teledyne Tekmar Fusion Tekmar Phoenix 8000 USP System Suitability Set (40 ml) Cat. #18004 Set of three vials includes (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. Teledyne Tekmar Validation Set Phoenix Cat. #19002 Set includes eighteen 40 ml vials, (2) Blanks, (3) 0.500 mg/l C NIST KHP, (6) 1.00 mg/l C NIST KHP, (1) 2.00 mg/l C NIST KHP, (1) 5.00 mg/l C NIST KHP, (1) 50.0 mg/l C NIST KHP, (1) 100 mg/l IC NaHCO 3, (1) USP Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. Teledyne Tekmar Validation Set Fusion Cat. #19004 Set includes twelve 40 ml vials and one 125 ml bottle, (3) Blanks, (3) 1.00 mg/l C NIST KHP, (1) 125 ml 5.00 mg/l C NIST KHP, (1) 10.0 mg/l C NIST KHP, (1) 25.0 mg/l IC NaHCO 3, (1) USP Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. Ultra Low-Level TOC CRMs Kit Cat. #14203 Set of 12 vials includes (3) TOC Water Blanks, (1) each of 0.050, 0.060, 0.070, 0.080, 0.090, 0.100, 0.250, 0.500 and 1.00 mg/l C from NIST KHP. 18 See page 21 for a complete list of Inorganic Carbon CRMs.

Reagents Teledyne Tekmar CRMs and Consumables TOC Key to accurate low-level analyses on pharmaceutical waters is keeping the overall instrument background (TOC contribution from the system ) as low as possible. ERA offers acid and persulfate reagents specifically for Teledyne Tekmar TOC systems that are manufactured with only the highest purity chemicals and ultra-clean containers. The care we take ensures the lowest possible contribution of background TOC from the reagents. Bulk Preserved USP System Suitability Sets These standards come packaged in ultra-clean amber bottles for use with Teledyne Tekmar TOC analyzers. Each standard has a 6-month expiration period from the day it is shipped. Each set contains (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. 125 ml Cat. #18024 250 ml Cat. #18049 500 ml Cat. #18104 1 Liter Cat. #18204 We offer one or two liter pre-made reagents for Teledyne Tekmar and OI Analytical TOC instruments. Acid and Persulfate Reagents Phosphoric Acid Reagent - 1 Liter Cat.# 21016 Ammonium Persulfate Reagent - 1 Liter Cat.# 21017 Phosphoric Acid Reagent - 2 Liter Cat.# 21018 Ammonium Persulfate Reagent - 2 Liter Cat.# 21019 Miscellaneous Consumables 40 ml Low TOC Vials (80/cs) Low TOC vials certified <10 ppb TOC Cat. #25025 See page 31 for more information on vials. From left to right: Debbie Roscoe, Production Chemist; Caroline Ball, Production Technician; Nick Hughes, Production Technician; Graham Roscoe, Managing Director ERA Manchester UK. web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 19

TOC Thornton TOC Analyzer Calibration and Validation CRMs Mettler-Toledo Thornton develops and manufactures instrumentation and sensors used for liquid process measurement and control in pure water applications, with extensive experience measuring resistivity/conductivity and TOC specifically. ERA offers the highest quality calibration and system suitability kits for your Thornton 5000 TOC meters. For conductivity we offer validation kits that allow an accurate, verifiable, and FDA-compliant approach to validating the sensors you use for USP <645> methods or your own. Please see pages 24-25 for a complete line of conductivity CRMs. Thornton 5000 System Suitability Set - 500 ml Cat. #18151 Thornton 5000 System Suitability Set Containing (2) Blanks Rw,(1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. Thornton 5000 Calibration Kit Cat. #11414 Thornton 5000 Calibration Kit Containing Calibration Blank (2), 0.250 mg/l C Sucrose (1), 0.500 mg/l C Sucrose (1) - 500 ml ea. Reagent Water Blank Cat. # 18144 USP reagent water blank Rw for Thornton 5000 TOC - 500 ml. Calibration Blank Cat. #11411 Calibration Blank for Thornton 5000 TOC - 500 ml. 0.500 mg/l C from USP Sucrose Cat. # 18145 USP Sucrose Rs at 0.500 mg/l C for Thornton 5000 TOC - 500 ml. 0.250 mg/l C from NIST Sucrose Cat. #11412 NIST Sucrose Calibration Standard at 0.250 mg/l C for Thornton 5000 TOC - 500 ml. 0.500 mg/l C from USP 1,4-Benzoquinone Cat. # 18146 USP 1,4-benzoquinone Rss at 0.500 mg/l C for Thornton 5000 TOC 500 ml. 0.500 mg/l C from NIST Sucrose Cat. #11413 NIST Sucrose Calibration Standard at 0.500 mg/l C for Thornton 5000 TOC - 500 ml. Thornton 5000 TOC with Multiparameter Transmitter 20

Inorganic Carbon CRMs IC A material derived from non-living sources, inorganic carbon (IC) exists in pharmaceutical waters as carbonate, bicarbonate and dissolved carbon dioxide (CO 2 ). Whether your instrument quantifies IC as part of a differential calculation or removes it as part of a non-purgeable method of TOC determination, your instruments ability to remove and/or measure IC must be validated. Below are the most commonly requested IC concentrations for calibration and validation of TOC instrumentation. Individual CRMs for Inorganic Carbon 0.500 mg/l IC from NIST NaHCO 3-40 ml Cat. #15990 0.500 mg/l IC from NIST NaHCO 3-125 ml Cat. #15995 0.500 mg/l IC from NIST NaHCO 3-500 ml Cat. #15992 1.00 mg/l IC from NIST NaHCO 3-40 ml Cat. #16000 1.00 mg/l IC from NIST NaHCO 3-500 ml Cat. #16100 1.00 mg/l IC from NIST NaHCO 3-1 Liter Cat. #16200 5.00 mg/l IC from NIST NaHCO 3-40 ml Cat. #16300 5.00 mg/l IC from NIST NaHCO 3-500 ml Cat. #16400 5.00 mg/l IC from NIST NaHCO 3-1 Liter Cat. #16500 10.0 mg/l IC from NIST NaHCO 3-40 ml Cat. #16600 10.0 mg/l IC from NIST NaHCO 3-125 ml Cat. #16620 10.0 mg/l IC from NIST NaHCO 3-500 ml Cat. #16700 10.0 mg/l IC from NIST NaHCO 3-1 Liter Cat. #16800 20.0 mg/l IC from NIST NaHCO 3-125 ml Cat. #12904 25.0 mg/l IC from NIST NaHCO 3-40 ml Cat. #16900 25.0 mg/l IC from NIST NaHCO 3-125 ml Cat. #16920 25.0 mg/l IC from NIST NaHCO 3-250 ml Cat. #16940 25.0 mg/l IC from NIST NaHCO 3-500 ml Cat. #17000 25.0 mg/l IC from NIST NaHCO 3-1 Liter Cat. #17100 50.0 mg/l IC from NIST NaHCO 3-40 ml Cat. #17130 100.0 mg/l IC from NIST NaHCO 3-40 ml Cat. #17150 100.0 mg/l IC from NIST NaHCO 3-125 ml Cat. #17153 100.0 mg/l IC from NIST NaHCO 3-500 ml Cat. #17160 100.0 mg/l IC from NIST NaHCO 3-1 Liter Cat. #17170 1000 mg/l IC from NIST NaHCO 3-250 ml Cat. #17154 2.50 mg/l C from NIST KHP and 25.0 mg/l IC from NIST NaHCO 3 - unpreserved - 40 ml 2.50 mg/l C from NIST KHP and 25.0 mg/l IC from NIST NaHCO 3 - unpreserved - 500 ml 2.50 mg/l C from NIST KHP and 25.0 mg/l IC from NIST NaHCO 3 - unpreserved - 125 ml 2.50 mg/l C from NIST KHP and 25.0 mg/l IC from NIST NaHCO 3 - unpreserved - 250 ml Cat. #12403 Cat. #12404 Cat. #12405 Cat. #12406 web WWW.ERAQC.COM US Will McHale Life Sciences Market Manager Your analytical instruments need to return accurate, reliable and defensible data with every single use. ERA's Six Sigma Quality Management System supports our philosophy of continuous quality and process improvement and was the foundation for our achieving ISO 17025 and ISO Guide 34 accreditation. P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 21

Conductivity ISO Guide 34 accredited since 2008, ERA is a certified reference materials producer and has been manufacturing conductivity reference standards for more than 30 years. ERA offers solutions and kits that support accurate, verifiable, and approved approaches to validating/verifying your conductivity sensors. Whether you are validating detection limits, determining accuracy and precision, or constructing a low-level linearity curve, ERA has the conductivity products and services to support your efforts.

Conductivity Probe Validation Kits Conductivity Pharmaceutical and medical grade waters used in product manufacturing must meet conductivity requirements as specified in USP <645>/ EP 2.2.38, where the off-line conductivity must be less than 1.3 μs/cm at 25 C. Deionized water has a theoretical purity of 0.055 μs/cm at 25 C, so the question is often asked why ultrapure water for injection (WFI) and purified water (PW) is considered acceptable in these applications when it displays conductivity levels 20 times the theoretical purity of water. The answer is simple; atmospheric carbon dioxide (CO 2 ) readily dissolves into ultrapure waters, contaminating the water with conductive ions and adding approximately 1.0 μs/cm of conductivity to ultrapure water at 25 C. As such, appropriately accurate/stable CRMs in the range of interest (0.055-1 μs/cm) are not available, and alternative approaches to validating the detection limits, linearity, precision and accuracy, of conductivity meters are necessary. For a technical note on the subject of Validating Conductivity Probes, please contact us at info@eraqc.com. web WWW.ERAQC.COM US From left to right: Will McHale, Life Sciences Market Manager; Veronica Meketuk, Chemist; Nicole Dean, Chemistry Technician; Tim Naiman, Chemistry Technician P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 23

Conductivity Conductivity Probe Validation Kits Validating the detection limits, accuracy and precision of a conductivity sensor in ultrapure water has been very elusive using traditional calibration solution schemes. Therefore, ERA is offering a three solution Validation Kit that will allow an accurate, verifiable, and approved approach to validating the sensor for your USP <645> methods. The kits come in single-use 125 ml volumes as well as multi-use 500 ml bottles. Each Validation Kit consists of three (3) conductivity calibration solutions. Measurements are made at each level and the results used to determine the Method Detection Limit (MDL), Limit of Detection (LOD) and Limit of Quantitation (LOQ). In addition, the data are used to verify probe accuracy and linearity. For a complete explanation of how to use the conductivity Probe Validation Kits, please call and request one of several application notes available from ERA. Individual Use 125 ml Conductivity Validation Kit Cat. #02850 Kit includes four bottles, (1) 25 μs/cm in Water, (1) 100 μs/cm in Water, (1) 146.93 μs/cm in Water (Solution D) and (1) Reagent Blank for use with Solution D. Multiple Use 500 ml Conductivity Validation Kit Cat. #02900 Kit includes four bottles, (1) 25 μs/cm in Water, (1) 100 μs/cm in Water, (1) 146.93 μs/cm in Water (Solution D) and (1) Reagent Blank for use with Solution D. Individual Low-Level Conductivity Standard 25 μs/cm in Water Our Solution 25 is an excellent verification solution once you have calibrated your system using our ASTM Solution D. This standard can verify that the accuracy of your cell meets the USP requirements and will positively demonstrate and document that you are using non-compensated conductivity measurements as required. Sievers Model 400 25 μs/cm - 30 ml Replaces Sievers Part STD 30030 Cat. #02700 Conductivity Calibration Standard Solution 25 at 25 μs/cm - 125 ml Cat. #01400 Solution 25 at 25 µs/cm - 250 ml Cat. #01350 Solution 25 Test Kit - 500 ml Includes Solution 25 and 5 pre-cleaned Cat. #01100 125 ml containers. Solution 25 at 25 μs/cm - 500 ml Cat. #01300 Solution 25 Test Kit - 1 Liter Includes Solution 25 and 10 pre-cleaned Cat. #01000 125 ml containers. Solution 25 at 25 μs/cm - 1 Liter Cat. #01200 Individual Mid-Level Conductivity Standard 100 µs/cm Manufactured using NIST traceable materials and certified, this KCl solution is an excellent calibration or calibration verification solution. This solution is certified by analysis and does not require the use of a reference blank for accurate calibration or validation. 125 ml Pre-cleaned HDPE containers for measuring calibration solutions. Cat. #02000 1 Liter Solution 100 Test Kit Includes Solution 100 and 10 pre-cleaned Cat. #02200 125 ml containers. Solution 100 at 100 µs/cm - 250 ml Cat. #02250 500 ml Solution 100 Test Kit Includes Solution 100 and 5 pre-cleaned Cat. #02300 125 ml containers. Solution 100 at 100 μs/cm - 1 Liter Cat. #02400 Solution 100 at 100 μs/cm - 500 ml Cat. #02500 Solution 100 at 100 μs/cm - 125 ml Cat. #02600 PAT 700 Conductivity Cat. #02602 Anatel Model A643 Conductivity Calibration Standard - 60 ml Cat. #02610 24

ASTM Standard Solutions Conductivity Probe Validation Kits ASTM solutions offer superior accuracy at mid- to high-levels for conductivity sensor validation and verification. These solutions are highly stable and widely accepted reference sources even in ultra-pure water applications. Manufactured according to the ASTM 1125 Test Method for conductivity and conductivity calibration. Conductivity Individual Mid-Level Conductivity Standards ASTM Solution D @ 146.93 μs/cm High-level Conductivity Solutions Made from KCl This solution is the lowest level solution that can be made following a NIST protocol for conductivity solution preparations. This standard makes an excellent calibration or verification solution together with our Solution 25. 1 Liter of Solution D at 146.93 μs/cm Includes Reference Blank. 500 ml of Solution D at 146.93 μs/cm Includes Reference Blank. 125 ml of Solution D at 146.93 μs/cm Includes Reference Blank. 1 Liter Solution D Test Kit Includes Solution D, Reference Blank, and 20 pre-cleaned 125 ml containers. 500 ml Solution D Test Kit Includes Solution D, Reference Blank, and 10 pre-cleaned 125 ml containers. Cat. #01700 Cat. #01800 Cat. #01900 Cat. #01500 Cat. #01600 Manufacturing the highest quality CRMs serves only as our starting point for ERA. As an organization, we search continuously for innovative ways to improve the accuracy, stability and convenience of our products. ASTM solutions C and D are prepared prescriptively from KCl and offer superior accuracy at mid- to high-levels for conductivity sensor validation and verification. Solution D at 146.93 μs/cm - 125 ml Cat. #01900 Solution D at 146.93 μs/cm 1000 ml Cat. #01700 Solution C at 1408.8 μs/cm - 125 ml Cat. #01610 Solution C at 1408.8 μs/cm 1000 ml Cat. #01620 Solution 10K at 10000 μs/cm - 125 ml Cat. #01630 Solution 10K at 10000 μs/cm 1000 ml Cat. #01640 Solution 100K at 100000 μs/cm - 125 ml Cat. #01650 Solution 100K at 100000 μs/cm 1000 ml Cat. #01660 Graham Roscoe Managing Director ERA Europe web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 25

CLEANING VALIDATION Born from what are now infamous pharmaceutical manufacturing errors made in the 1980s, the "Guide to Inspections of Validation of Cleaning Processes" served as the foundation for critical evaluation of cleaning needs and solutions, eventually infiltrating the Code of Federal Regulations (CFR), or as it is sometimes called the administrative law of the United States. Since the issuance of that document, cleaning validation has received increasing attention not only in manufacturing, but also in research and development. To ensure that the sampling techniques meet established acceptance criteria, pre-validation feasibility studies and method development must be performed. ERA is your source for coupons, swabs, templates and vials everything you need for recovery studies and routine verification sampling.

Cleaning Validation Products ERA is the premier manufacturer of specialty cleaning validation products. We provide coupons, certified clean sample vials and swabs for swab recovery studies, as well as kits that can be customized to suit your laboratory, analyst and validation needs. CLEANING VALIDATION web WWW.ERAQC.COM US Swabs Large Polyester Swabs with snap-off head for use with TOC. Cat# 30031 100 swabs (two bags of 50 each) Similar to TX714K Ultra-low interference levels (< 50.0 ppb TOC) Large Polyester Swabs with snap-off head for use with HPLC. Cat# 30030 100 swabs (two bags of 50 each) Similar to TX715 Ultra-low interference levels (Abs254: 0.1 au max.) CV Swabbing Templates 16 cm 2 (pack of 25) Cat# 30028 25 cm 2 (pack of 25) Cat# 30029 100 cm 2 (pack of 25) Cat# 30032 ERA pre-cleaned Teflon swabbing templates are a simple way to ensure accuracy and precision in your cleaning validation sampling (stainless steel available upon request). Each pack comes with a C of A for residual HPLC and TOC levels. Our disposable/reusable templates are available in 16, 25 and 100 cm 2 areas or can be custom made to your needs (call for pricing and custom sizing). From left to right: Stan Dunlavy, Product Line Manager; Mike Mendoza, Shipping and Receiving; Patrick Yast, Shipping and Receiving P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 27

CLEANING VALIDATION Cleaning Validation Coupons ERA is a leading supplier of coupons for cleaning validation applications. We provide coupons in all the standard materials you would expect, but go out of our way to service our customers rarest requests like glass-coated ceramics. Whatever your specific application, call ERA for your next coupon project and experience service from a team of professionals that understand your application. While every coupon order is treated as a custom request, only the experience is special. Our pricing underscores the value of doing business with our life science experts. Place just one order with ERA and you won t ever go anywhere else for coupons. Custom Coupons from ERA Custom plastic or rubber coupon for cleaning validation. Cat# 30024 Custom metal coupon for cleaning validation. Cat# 30025 Custom glass coupon for cleaning validation. Cat# 30027 Please have the following information available at the time of your quote request: Material Grade Finish Coating Etching Durometer Dimensions Thickness Quantity Metal, plastic, rubber or glass type (stainless steel, polyethylene, etc.). Specific grade of material; like 316 stainless, HDPE or borosilicate glass. Arguably the most important factor. The finish usually refers to the surface roughness and can be stated in terms of grit or Ra values for metals. It is most often measured using a profilometer. Most materials can be coated to offer desirable surface properties. Most materials can be etched with serial numbers, swabbing areas or other information. A material density, or hardness value for rubber. Size and shape of the coupon. You can request a certain thickness for your coupons or a suitable one will be chosen. The quantity of coupons needed. 28

Cleaning Validation Sampling Kits Vial and Swab Sampling Kit 25 certified clean swabs 12 certified clean vials Vial and Swab Sampling Kit 160 certified clean swabs 80 certified clean vials Cleaning Validation Products Kits Cat. #CV10000 Cat. #CV10005 CLEANING VALIDATION web WWW.ERAQC.COM US From left to right: Tanya Rahn, Sales Representative; Heidi White, Corporate Account Executive; Rick Persichitte, Western Region Sales Manager; Melissa Wright, Sales Representative P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 29

SAMPLE Vials and Containers Ever wonder what the USP means by: Use glassware and sample containers that have been scrupulously cleaned of organic residues? 1 Just like the USP, we here at ERA demand scrupulously cleaned vials for our TOC standards. All of our vials, whether glass or polymer, represent the most consistently clean sample vials available anywhere. They are the perfect vial for your purified water (PW) or water for injection (WFI) sample analysis. 1 United States Pharmacopeia Monographs, Chapter <661> - Containers.

All ERA vials and bottles, whether glass or polymer, represent the most consistently clean sample containers available anywhere. 40 ml Glass TOC vials Sample Vials and Containers Plastic Containers Plastic Containers Anatel SAMPLE VIALS AND CONTAINERS 60 ml HDPE Bottle for Anatel A643 (natural) Cat. #25030 60 ml HDPE Bottle for A643 (natural) - Pack of 25 Cat. #25031 60 ml HDPE Bottle for Anatel A643 (amber) Cat. #25033 60 ml HDPE Bottle for A643 (amber) - Pack of 25 Cat. #25034 Sievers 40 ml Low TOC Vials (80/cs) Cat. #25025 Our cleaning process removes virtually all residual TOC from our 40 ml sample vials; our average residual TOC level is < 10 ppb. How do we know this? Because we analyze every single batch. Over the years our data demonstrates that these vials are uniformly lower in TOC than any other vial available. Each case of vials (80 per case) comes with a C of A to document their quality. Each vial is capped with a Teflon-lined septa and protected by a hardened plastic dust cover. We guarantee these low-level TOC vials will exceed your expectations. 30 ml Poly Vial for use with Sievers Model 400 TOC analyzers 125mL Pre-cleaned HDPE container for measuring calibration solutions From left to right: Sylvia Lowe, International Customer Service Representative; Jennifer Watson, Customer Service Representative; Heidi Senft, Customer Service Representative; Darren Sauer, Customer Service Representative; Julie Lawson, Customer Service Manager; Deborah Updyke, Customer Service Representative Cat. #25015 Cat. #02000 web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 31

Turbidity, Residual Solvents, Reagents and Purified Water ISO Guide 34 accredited since 2008, ERA is a certified reference materials producer and has been manufacturing reference standards for inorganic carbon, conductivity and turbidity analysis for more than 30 years. ERA is also a supplier of ultra-clean inorganic acids and reagents. Whether your application is ultra-pure water TOC analysis or metals analysis via ICP-MS, ERA has the right calibration material for you.

ERA s turbidity products are manufactured under our ISO Guide 34 accreditation as a reference material producer and are designed specifically for pharmaceutical turbidimetric validation, calibration and monitoring applications. Whether our customers are performing particle content/ concentration monitoring for fermentation progress or filter break monitoring, we guarantee your satisfaction with ERA turbidity reference materials. Our custom product group is always happy to fulfill specialized customer requests. If there is a turbidity product you are looking for that you don t see here, please contact us at: customs@eraqc.com or 1-800-554-2511. Individual Turbidity CRMs Turbidity CRMs 25 NTU Turbidity Cal CRM - 1 Liter Cat. #14105 50 NTU Turbidity Cal CRM - 1 Liter Cat. #14106 100 NTU Turbidity Cal CRM - 1 Liter Cat. #14107 150 NTU Turbidity Cal CRM - 1 Liter Cat. #14108 175 NTU Turbidity Cal CRM - 1 Liter Cat. #14109 200 NTU Turbidity Cal CRM - 1 Liter Cat. #14110 250 NTU Turbidity Cal CRM - 1 Liter Cat. #14111 300 NTU Turbidity Cal CRM - 1 Liter Cat. #14112 350 NTU Turbidity Cal CRM - 1 Liter Cat. #14113 400 NTU Turbidity Cal CRM - 1 Liter Cat. #14114 450 NTU Turbidity Cal CRM - 1 Liter Cat. #14115 500 NTU Turbidity Cal CRM - 1 Liter Cat. #14116 Turbidity Calibration Set (25, 50, 100, 175, 250 NTU) - 5 x 1 Liter Cat. #14117 Turbidity Calibration Set High (50, 100, 200, 300, 400, 500 NTU) - 6 x 1 Liter Cat. #14118 Turbidity Calibration Set Low (0.1, 25, 50, 100, 175 NTU) - 5 x 1 Liter Cat. #14119 Turbidity web WWW.ERAQC.COM US From left to right: Kristi Medley, Director of Accounting & Finance; Kathleen De La Cruz, Billing & Collections; Isabelle DeLeon, Receptionist; June Marx, Human Resources & Accounting; Maya Chain, Senior Accountant; Ellen Geisbrecht, Accounting P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 33

Customs USP <467> Residual Solvents CRMs Our experience demonstrates that the best approach to servicing our USP <467> customers is to prepare the calibration and QC reference materials especially for their manufacturing criteria. We would be happy to make exactly the combination of analyte and matrix that reflects your application. Please call us today to discuss how we can help your facility. Whether you need methanol in DMSO or a 15-analyte mix in DMI, contact us for a quote on your custom-designed Residual Solvent calibration or QC reference material. Class 1 Mixes: 1-5 analytes from class 1 table @ 0.250 50.0 mg/l Class 2 Mixes: 1-15 analytes from class 2 table @ 0.250 50.0 mg/l Class 3 Mixes: 1-8 analytes from class 3 table @ 0.250 50.0 mg/l Multi-Class Mixes: 1-28 analytes from any table @ 0.250 50.0 mg/l Custom Standards and Services Quality Focus Calibration standards, stock solutions, matrix spikes; if a reference standard can be made, ERA will be happy to prepare it for you and supply a comprehensive Certificate of Analysis with it. We have experience with: Chemical, microbiological and radiochemical analytes Calibration/Linearity/LOD kits for GC, ICP, LC, MS, TOC, conductivity Ultra trace to percent levels Swab recovery studies Visible residue limit determination Matrix flexibility: water, brine, food, soil, biological tissues, plant materials, etc. Project/site-specific and client-supplied matrices One standard or hundreds of standards Managed methodology studies John Laferty Product Line Manager As Product Line Manager for Life Sciences and Custom products at ERA, it is exciting to be responsible for creating solutions for our customers challenges every day. We ensure the highest levels of care and quality go into each of the products that we make, whether it is our most popular catalog item or a custom solution for just one individual. Are custom standards expensive? While the cost of custom standards certainly depends on the complexity of your requirements, the costs for most simple standards is very reasonable. The final cost is dependent on many factors, including the materials used, time required, complexity of the standards and extent of analytical validation required. In every case, you will receive a fixed price quotation based upon your project-specific requirements and you can count on ERA to deliver what you need, when you need it. Now that s versatility. 34

Reagents ERA manufactures industrial reagents with tolerances of ± 0.5%, and will hold the certified value lot to lot within 0.5%. Our NIST-traceable reagents are shipped with a Certificate of Analysis and are homogenous at a 95% confidence interval. If you have been looking for a company to manufacture high quality, stable, consistent reagents for your specialized needs, please contact our reagent group today for a quote: customs@eraqc.com or 1-800-554-2511. ERA manufactures many reagents for standard laboratory analysis as well as custom formulations to accommodate customer needs. Reagents EDTA ph Buffers EDTA - (0.01M, 1 Gallon) Cat. #183160 EDTA - (0.1M, 1 Liter) Cat. #183118 EDTA - (0.1M, 1 Gallon) Cat. #183120 EDTA - (0.1M, 5 Gallon) Cat. #187525 Hydrochloric Acid Hydrochloric Acid - (0.01N, 1 Liter) Cat. #183026 Hydrochloric Acid - (0.01N, 1 Gallon) Cat. #183028 Hydrochloric Acid - (0.01N, 5 Gallon) Cat. #187503 Hydrochloric Acid - (0.1N, 1 Liter) Cat. #183030 Hydrochloric Acid in IPA - (0.1N, 1 Liter) Cat. #184001 Hydrochloric Acid - (0.1N, 2.5 Liter) Cat. #183010 Hydrochloric Acid - (0.1N, 1 Gallon) Cat. #183032 Hydrochloric Acid - (0.1N, 5 Gallon) Cat. #187506 Hydrochloric Acid - (0.25N, 1 Liter) Cat. #183034 Hydrochloric Acid - (0.25N, 1 Gallon) Cat. #183036 Hydrochloric Acid - (0.25N, 5 Gallon) Cat. #187507 Hydrochloric Acid - (0.5N, 1 Liter) Cat. #183038 Hydrochloric Acid - (0.5N, 1 Gallon) Cat. #183040 Hydrochloric Acid - (0.5N, 5 Gallon) Cat. #187508 Hydrochloric Acid - (0.645N, 5 Gallon) Cat. #183016 Hydrochloric Acid - (1.0N, 1 Liter) Cat. #183042 Hydrochloric Acid - (1.0N, 1 Gallon) Cat. #183044 Hydrochloric Acid - (1.0N, 5 Gallon) Cat. #187510 Sulfuric Acid Sulfuric Acid - (0.01N, 1Liter) Cat. #183048 Sulfuric Acid - (0.01N, 1 Gallon) Cat. #183049 Sulfuric Acid - (0.02N, 1 Liter) Cat. #183050 Sulfuric Acid - (0.02N, 1 Gallon) Cat. #183052 Sulfuric Acid - (0.02N, 5 Gallon) Cat. #187511 Sulfuric Acid - (0.05N, 1 Liter) Cat. #183003 Sulfuric Acid - (0.1N, 1 Liter) Cat. #183054 Sulfuric Acid - (0.1N, 1 Gallon) Cat. #183056 Sulfuric Acid - (0.1N, 5 Gallon) Cat. #187512 Sulfuric Acid - (0.2N, 1 Liter) Cat. #183058 Sulfuric Acid - (0.2N, 1 Gallon) Cat. #183060 Sulfuric Acid - (0.2N, 5 Gallon) Cat. #187514 Sulfuric Acid - (0.5N, 1 Liter) Cat. #183062 Sulfuric Acid - (0.5N, 1 Gallon) Cat. #183064 Sulfuric Acid - (1.0N, 1 Liter) Cat. #183066 Sulfuric Acid - (1.0N, 1 Gallon) Cat. #183068 Sulfuric Acid - (1.0N, 5 Gallon) Cat. #187515 ERA Cal ph Buffers are directly traceable to NIST SRMs, mercury free, guaranteed stable for at least one year after your receipt, and are supplied with a full certificate of analysis. Choose single bottles or convenient 6-bottle cases. Value Volume Single Bottles Case of 6 Bottles ph 4.00 (red) 1 pint Cat. # 127 Cat. # 128 ph 7.00 (yellow) 1 pint Cat. # 131 Cat. # 132 ph 10.00 (green) 1 pint Cat. # 135 Cat. # 136 Case of 2 ea. pints Cat. # 141 Potassium Hydroxide Potassium Hydroxide - (0.01N, 1 Liter) Cat. #183090 Potassium Hydroxide - (0.01N, 1 Gallon) Cat. #183092 Potassium Hydroxide - (0.01N, 5 Gallon) Cat. #187521 Potassium Hydroxide - (0.1N, 1 Liter) Cat. #183094 Potassium Hydroxide in IPA - (0.1N, 1 Gallon) Cat. #183211 Potassium Hydroxide - (0.1N, 1 Gallon) Cat. #183096 Potassium Hydroxide - (0.1N, 5 Gallon) Cat. #187522 Potassium Hydroxide - (0.25N, 1 Liter) Cat. #183098 Potassium Hydroxide - (0.25N, 1 Gallon) Cat. #183100 Potassium Hydroxide - (0.25N, 5 Gallon) Cat. #187523 Potassium Hydroxide - (0.5N, 1 Liter) Cat. #183102 Potassium Hydroxide - (0.5N, 1 Gallon) Cat. #183104 Potassium Hydroxide - (0.5N, 5 Gallon) Cat. #187524 Sodium Hydroxide Sodium Hydroxide (0.01N, 1 Liter) Cat. #183070 Sodium Hydroxide (0.01N, 1 Gallon) Cat. #183072 Sodium Hydroxide (0.01N, 5 Gallon) Cat. #187516 Sodium Hydroxide (0.1N, 1 Liter) Cat. #183074 Sodium Hydroxide (0.1N, 1 Gallon) Cat. #183076 Sodium Hydroxide (0.1N, 5 Gallon) Cat. #187517 Sodium Hydroxide (0.25N, 1 Liter) Cat. #183078 Sodium Hydroxide (0.25N, 1 Gallon) Cat. #183080 Sodium Hydroxide (0.25N, 5 Gallon) Cat. #187518 Sodium Hydroxide (0.5N, 1 Gallon) Cat. #183082 Sodium Hydroxide (0.5N, 5 Gallon) Cat. #187519 Sodium Hydroxide (1.0N, 1 Liter) Cat. #183086 Sodium Hydroxide (1.0N, 1 Gallon) Cat. #183088 Sodium Hydroxide (1.0N, 5 Gallon) Cat. #183156 web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 35

Purified Water High-Purity Water ERA offers certified low-toc water suitable for use with your TOC or liquid chromatography system. All of our waters are prepared with the highest level of care throughout the Ion-Exchange-Filtration-RO-UV purification process. Our waters must pass a rigorous testing scheme and we guarantee the analysis of each bottle as well as your satisfaction. USP Purified Certified Low TOC Water USP purified Low TOC Water 4 Liter USP purified Low TOC Water 4 x 4 Liter case Cat. #PW10000 Cat. #PW10005 Guaranteed Specifications: ph 5-7 Residue after Evaporation 1 mg/l max. Conductivity (at Bottling) 1.1 µs/cm max @ 20 C Total Organic Carbon 50 ppb max. Total Bacterial Count < 10 cfu/ml Color (APHA) 5 max. Absorbance 0.1 au max. Elemental Analysis: Ag (Silver) Max. 0.0004 mg/l Fe (Iron) Max. 0.001 mg/l Al (Aluminium) Max. 0.002 mg/l Mn (Manganese) Max. 0.0004 mg/l As (Arsenic) Max. 0.002 mg/l Mo (Molybdenum) Max. 0.002 mg/l B (Boron) Max. 0.005 mg/l Ni (Nickel) Max. 0.0004 mg/l Ba (Barium) Max. 0.001 mg/l Pb (Lead) Max. 0.001 mg/l Be (Beryllium) Max. 0.002 mg/l Sb (Antimony) Max. 0.001 mg/l Cd (Cadmium) Max. 0.001 mg/l Se (Selenium) Max. 0.0001 mg/l Co (Cobalt) Max. 0.001 mg/l Sr (Strontium) Max. 0.0004 mg/l Cr (Chromium) Max. 0.0004 mg/l Tl (Thallium) Max. 0.00005 mg/l Cu (Copper) Max. 0.0004 mg/l From left to right: Eric Leonard, Chemistry Technician; David Kilhefner, Director of Manufacturing; Chad Lane, Inorganic Chemist; John Laferty, Product Line Manager; Tony Ciacco, Inorganic Chemist 36

TOC CRMs by Manufacturer Manufacturer Page Anatel 38 Analytik Jena and Lachat 41-43 OI Analytical 42-43 Shimadzu 42-43 Sievers 39-41 Teledyne Tekmar 42-43 Thornton 43

TOC CRMs BY MANUFACTURER All of ERA s unpreserved standards have a minimum 30-day expiration period regardless of size. Preserved single-use standards have a 60-day expiration period and bulk preserved standards have a six-month expiration period. The following is not a complete list of all volumes and concentrations of TOC standards offered by ERA. Please call us if there is a product you need and it is not listed. Anatel A643 60 ml Low TOC Bottles 60 ml HDPE Bottle for A643 (natural) Cat. #25030 60 ml HDPE Bottle for A643 (amber) Cat. #25033 60 ml HDPE Bottle for A643 (natural) - Pack of 25 Cat. #25031 60 ml HDPE Bottle for A643 (amber) - Pack of 25 Cat. #25034 60 ml Single-Use A643 Standards PAT 700 PAT 700 Conductivity Solution Kit Cat. #02602 PAT 700 System Suitability Kit Cat. #18402 PAT 700 Calibration Standards Kit Cat. #19202 PAT 700 Validation Control Kit Cat. #19222 PAT 700 Validation Protocol Reagent Kit Cat. #19232 PAT 700 Excursion with Validation Kit Cat. #19250 PAT 700 Excursion Kit Cat. #25100 100 μs/cm Conductivity Soln Kit Cat. #02610 Calibration Blank Cat. #13300 0.250 mg/l C NIST Sucrose Cat. #13400 0.500 mg/l C NIST Sucrose Cat. #13500 0.750 mg/l C NIST Sucrose Cat. #13600 USP System Suitability Set Cat. #18400 USP System Suitability Kit with 250 ppb check Cat. #13390 A643 Calibration Standards Kit Cat. #19200 A643 Validation Kit Cat. #19210 A643 Validation Control Kit Cat. #19220 A643 Validation Protocol Standards Kit Cat. #19230 Low TOC Sample Vial Kit Cat. #25045 Bulk Packaged CRMs for Anatel 643 and TOC 600 Calibration Blank 125 ml (TOC 600) Cat. #10019 0.250 mg/l C NIST Sucrose 125 ml (TOC 600) Cat. #10319 0.500 mg/l C NIST Sucrose 125 ml (TOC 600) Cat. #10619 0.750 mg/l C NIST Sucrose 125 ml (TOC 600) Cat. #10919 100 μs/cm Conductivity Cal Standard 125 ml (TOC 600) Cat. #02600 System Suitability Set 125 ml Cat. #18035 Calibration Blank 250 ml Cat. #10031 0.250 mg/l C NIST Sucrose 250 ml Cat. #10331 0.500 mg/l C NIST Sucrose 250 ml Cat. #10631 0.750 mg/l C NIST Sucrose 250 ml Cat. #10931 100 μs/cm Conductivity Soln Standard 250 ml Cat. #02250 System Suitability Set 250 ml Cat. #18060 Calibration Blank 500 ml Cat. #10120 0.250 mg/l C NIST Sucrose 500 ml Cat. #10420 0.500 mg/l C NIST Sucrose 500 ml Cat. #10720 0.750 mg/l C NIST Sucrose 500 ml Cat. #11020 100 μs/cm Conductivity Cal Standard 500 ml Cat. #02500 System Suitability Set 500 ml Cat. #18150 Anatel AnaTOC and A1000 Single-Use Anatel AnaTOC CRMs TOC Water Blank 125 ml Cat. #10015 0.250 mg/l C NIST KHP 125 ml Cat. #11720 0.500 mg/l C NIST KHP 125 ml Cat. #11730 1.00 mg/l C NIST KHP 125 ml Cat. #11810 USP System Suitability Set 125 ml Cat. #18025 TOC Water Blank 250 ml Cat. #10025 0.250 mg/l C NIST KHP 250 ml Cat. #11721 0.500 mg/l C NIST KHP 250 ml Cat. #11735 1.00 mg/l C NIST KHP 250 ml Cat. #11820 USP System Suitability Set 250 ml Cat. #18050 TOC Water Blank 500 ml Cat. #10100 0.250 mg/l C NIST KHP 500 ml Cat. #11722 0.500 mg/l C NIST KHP 500 ml Cat. #11750 1.00 mg/l C NIST KHP 500 ml Cat. #11900 1000 mg/l C NIST KHP 500 ml Cat. #13299 USP System Suitability Set 500 ml Cat. #18100 40 ml Low TOC vials (80/cs) Cat. #25025 Single-use CRMs for the Anatel A-1000 Calibration Blank 1 Liter Cat. #10211 0.250 mg/l C NIST Sucrose 1 Liter Cat. #10511 0.500 mg/l C NIST Sucrose 1 Liter Cat. #10811 0.750 mg/l C NIST Sucrose 1 Liter Cat. #11111 USP System Suitability Set 1 Liter Cat. #19030 Please see pages 9-11 for Anatel product descriptions. 38

Sievers 400 and 400 ES System Suitability Sets System Suitability Set - 30 ml Cat. #18300 System Suitability Set - 125 ml Cat. #18030 System Suitability Set - 250 ml Cat. #18055 System Suitability Set - 500 ml Cat. #18140 System Suitability Set - 1 Liter Cat. #18240 30 ml Unpreserved CRMs Calibration Blank Cat. #13700 1.25 mg/l C NIST Sucrose for calibration Cat. #14100 25 μs/cm Conductivity for calibration Cat. #02700 Bulk Packaged CRMs for the Model 400 30 day expiration 125 ml TOC Calibration CRMs Calibration Blank Cat. #10020 1.25 mg/l C NIST Sucrose Calibration Standard Cat. #11520 25 μs/cm Conductivity Calibration Standard Cat. #01400 250 ml TOC Calibration CRMs Calibration Blank Cat. #10030 1.25 mg/l C NIST Sucrose Calibration Standard Cat. #11530 25 μs/cm Conductivity Calibration Standard Cat. #01350 500 ml TOC Calibration CRMs Calibration Blank Cat. #10110 1.25 mg/l C NIST Sucrose Calibration Standard Cat. #11601 25 μs/cm Conductivity Calibration Standard Cat. #01300 Model 400 Calibration Set Calibration Blank, 1.25 mg/l C NIST Sucrose, 25 µs/cm Conductivity. Cat. # 14101 Sievers 500 RL (Standard IOS) Single-Use CRMs System Suitability Set (Replaces CSTD 74403) Cat. #15105 Single-Point Cal Set (Replaces CSTD 74401) Cat. #15100 Single-Point Cal/Veri Set (Replaces CSTD 74612) Cat. #15101 Multi-Point Cal Set (Replaces CSTD 74614) Cat. #15102 Multi-Point Cal/Veri Set (Replaces CSTD 74616) Cat. #15103 Acc/Prec/Veri Set (Replaces CSTD 74402) Cat. #15104 Linearity Set (Replaces CSTD74406) Cat. #15106 Single-Point Validation Set (Replaces CSTD 74613) Cat. #15107 Multi-Point Validation Set (Replaces CSTD 74615) Cat. #15108 Single-Point Cal Set - TOC Only (Replaces CSTD 74405) Cat. #15109 Acc/Prec/Veri Set - TOC Only (Replaces CSTD 74407) Cat. #15110 Single-Point Cal/Veri Set - TOC Only (Replaces CSTD 74622) Cat. #15111 Multi-Point Cal Set - TOC Only (Replaces CSTD 74624) Cat. #15112 Multi-Point Cal/Veri Set - TOC Only (Replaces CSTD 74626) Cat. #15113 For more individual and bulk standards visit www.eraqc.com. TOC CRMs BY MANUFACTURER web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 39

TOC CRMs BY MANUFACTURER Sievers 500, 800 and 900, AJ N/C 2100/3100, Lachat IL 550 40 ml NIST KHP CRMs TOC Water Blank Cat. #10000 0.050 mg/l C NIST KHP Cat. #11701 0.060 mg/l C NIST KHP Cat. #11704 0.070 mg/l C NIST KHP Cat. #11707 0.080 mg/l C NIST KHP Cat. #11710 0.090 mg/l C NIST KHP Cat. #11713 0.100 mg/l C NIST KHP Cat. #11716 0.250 mg/l C NIST KHP Cat. #11719 0.500 mg/l C NIST KHP Cat. #11725 0.750 mg/l C NIST KHP Cat. #11780 1.00 mg/l C NIST KHP Cat. #11800 2.00 mg/l C NIST KHP Cat. #12100 4.00 mg/l C NIST KHP Cat. #12350 5.00 mg/l C NIST KHP Cat. #12400 10.0 mg/l C NIST KHP Cat. #12700 12.0 mg/l C NIST KHP Cat. #12905 12.5 mg/l C NIST KHP Cat. #12910 15.0 mg/l C NIST KHP Cat. #12940 25.0 mg/l C NIST KHP Cat. #13000 30.0 mg/l C NIST KHP Cat. #13210 50.0 mg/l C NIST KHP Cat. #13225 100 mg/l C NIST KHP Cat. #13275 150 mg/l C NIST KHP Cat. #13280 200 mg/l C NIST KHP Cat. #13285 250 mg/l C NIST KHP Cat. #13290 500 mg/l C NIST KHP Cat. #13295 See pages 12-14 for calibration and validation set descriptions. System Suitability Sets Each system suitability set contains (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. 125 ml Bulk NIST KHP CRMs TOC Water Blank Cat. #10015 0.050 mg/l C NIST KHP Cat. #11702 0.100 mg/l C NIST KHP Cat. #11717 0.250 mg/l C NIST KHP Cat. #11720 0.500 mg/l C NIST KHP Cat. #11730 0.750 mg/l C NIST KHP Cat. #11785 1.00 mg/l C NIST KHP Cat. #11810 2.00 mg/l C NIST KHP Cat. #12110 4.00 mg/l C NIST KHP Cat. #12360 5.00 mg/l C NIST KHP Cat. #12410 10.0 mg/l C NIST KHP Cat. #12710 12.5 mg/l C NIST KHP Cat. #12912 15.0 mg/l C NIST KHP Cat. #12945 25.0 mg/l C NIST KHP Cat. #13020 50.0 mg/l C NIST KHP Cat. #13226 USP System Suitability Set - 40 ml Cat. #18000 USP Reagent Water - 40 ml Cat. #18001 0.500 mg/l C USP Sucrose - 40 ml Cat. #18002 0.500 mg/l C USP 1,4-benzoquinone - 40 ml Cat. #18003 USP System Suitability Set - 125 ml Cat. #18025 USP System Suitability Set - 250 ml Cat. #18050 USP System Suitability Set - 500 ml Cat. #18100 USP System Suitability Set - 1 Liter Cat. #18200 Validation Sets (40 ml vials) Sievers 800 Autosampler Calibration Set Cat. #19500 Sievers 800 Grab Mode Calibration Set Cat. #19510 Sievers 800 Linearity Set Cat. #19515 Sievers 800 Low-Level Validation Set Cat. #19520 Model 900 Cal & Val Calibration Set (Replaces CSTD 90016) Cat. #19600 Model 900 Multi -Point Calibration Set (Replaces CSTD 90000) Cat. #19610 Model 900 Autoreagents Calibration Set (Replaces CSTD 90036) Cat. #19611 250 ml Bulk NIST KHP CRMs TOC Water Blank Cat. #10025 0.050 mg/l C NIST KHP Cat. #11703 0.100 mg/l C NIST KHP Cat. #11718 0.250 mg/l C NIST KHP Cat. #11721 0.500 mg/l C NIST KHP Cat. #11735 0.750 mg/l C NIST KHP Cat. #11790 1.00 mg/l C NIST KHP Cat. #11820 2.00 mg/l C NIST KHP Cat. #12120 5.00 mg/l C NIST KHP Cat. #12420 10.0 mg/l C NIST KHP Cat. #12720 12.5 mg/l C NIST KHP Cat. #12914 15.0 mg/l C NIST KHP Cat. #12950 25.0 mg/l C NIST KHP Cat. #13040 50.0 mg/l C NIST KHP Cat. #13228 100 mg/l C NIST KHP Cat. #13277 40

Sievers 500, 800 and 900, AJ N/C 2100/3100, Lachat IL 550 500 ml Bulk NIST KHP CRMs TOC Water Blank Cat. #10100 0.100 mg/l C NIST KHP Cat. #11714 0.250 mg/l C NIST KHP Cat. #11722 0.500 mg/l C NIST KHP Cat. #11750 0.750 mg/l C NIST KHP Cat. #11795 1.00 mg/l C NIST KHP Cat. #11900 2.00 mg/l C NIST KHP Cat. #12200 5.00 mg/l C NIST KHP Cat. #12500 10.0 mg/l C NIST KHP Cat. #12800 12.5 mg/l C NIST KHP Cat. #12920 15.0 mg/l C NIST KHP Cat. #12955 25.0 mg/l C NIST KHP Cat. #13100 30.0 mg/l C NIST KHP Cat. #13215 50.0 mg/l C NIST KHP Cat. #13230 100 mg/l C NIST KHP Cat. #13278 1 Liter Bulk NIST KHP CRMs TOC Water Blank Cat. #10200 0.100 mg/l C NIST KHP 1 Liter Cat. #11715 0.250 mg/l C NIST KHP 1 Liter Cat. #11723 0.500 mg/l C NIST KHP 1 Liter Cat. #11775 1.00 mg/l C NIST KHP 1 Liter Cat. #12000 2.00 mg/l C NIST KHP 1 Liter Cat. #12300 5.00 mg/l C NIST KHP 1 Liter Cat. #12600 10.0 mg/l C NIST KHP 1 Liter Cat. #12900 12.5 mg/l C NIST KHP 1 Liter Cat. #12930 25.0 mg/l C NIST KHP 1 Liter Cat. #13200 30.0 mg/l C NIST KHP 1 Liter Cat. #13220 50.0 mg/l C NIST KHP 1 Liter Cat. #13235 100 mg/l C NIST KHP 1 Liter Cat. #13279 200 mg/l C NIST KHP 1 Liter Cat. #13289 500 mg/l C NIST KHP 1 Liter Cat. #13297 Miscellaneous Consumables Replacement UV Lamps Replacement UV Lamp for Sievers Model 400 Cat. #20040 Replacement UV Lamp for Sievers Model 500 Cat. #20045 Filters, Tubing and Cartridges 60 Micron in-line Stainless Filter Cat. #25035 Fan filter for Sievers Model 400 and 800 Cat. #25040 Replacement pump-tubing for Sievers Model 400 Cat. #20055 Replacement pump-tubing for Sievers Model 800 Cat. #20050 Replacement pump-tubing for Sievers Model 900 Cat. #20060 Sievers 900 replacement resin cartridge Cat. #20038 30 ml Poly Vials 30 ml polymer vials for use with Sievers Model 400 TOC analyzers. 40 ml Low TOC Vials (80/cs) Cat. #25015 Low TOC vials certified <10 ppb TOC Cat. #25025 NIST Sucrose CRMs 0.250 mg/l C NIST Sucrose 40 ml Cat. #10300 0.250 mg/l C NIST Sucrose 125 ml Cat. #10315 0.250 mg/l C NIST Sucrose 250 ml Cat. #10321 0.250 mg/l C NIST Sucrose 500 ml Cat. #10400 0.250 mg/l C NIST Sucrose 1 Liter Cat. #10500 0.500 mg/l C NIST Sucrose 40 ml Cat. #10600 0.500 mg/l C NIST Sucrose 125 ml Cat. #10615 0.500 mg/l C NIST Sucrose 250 ml Cat. #10621 0.500 mg/l C NIST Sucrose 500 ml Cat. #10700 0.500 mg/l C NIST Sucrose 1 Liter Cat. #10800 0.750 mg/l C NIST Sucrose 40 ml Cat. #10900 0.750 mg/l C NIST Sucrose 125 ml Cat. #10915 0.750 mg/l C NIST Sucrose 250 ml Cat. #10921 0.750 mg/l C NIST Sucrose 500 ml Cat. #11000 0.750 mg/l C NIST Sucrose 1 Liter Cat. #11100 1.00 mg/l C NIST Sucrose 40 ml Cat. #11200 1.00 mg/l C NIST Sucrose 125 ml Cat. #11215 1.00 mg/l C NIST Sucrose 250 ml Cat. #11221 1.00 mg/l C NIST Sucrose 500 ml Cat. #11300 1.00 mg/l C NIST Sucrose 1 Liter Cat. #11400 1.25 mg/l C NIST Sucrose 40 ml Cat. #11500 1.25 mg/l C NIST Sucrose 500 ml Cat. #11600 1.25 mg/l C NIST Sucrose 1 Liter Cat. #11650 From left to right: Lisa Berry, Director of Production Planning; Jay McBurney, Quality Program Manager; Dale Shallenberger, Procurement & Inventory Control TOC CRMs BY MANUFACTURER web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 41

TOC CRMs BY MANUFACTURER OI Analytical, Shimadzu, Teledyne Tekmar, AJ N/C UV HS, and Lachat IL 500 40 ml Single Use Vials TOC Water Blank Cat. #10001 0.050 mg/l C NIST KHP Cat. #11666 0.060 mg/l C NIST KHP Cat. #11669 0.070 mg/l C NIST KHP Cat. #11670 0.080 mg/l C NIST KHP Cat. #11671 0.090 mg/l C NIST KHP Cat. #11672 0.100 mg/l C NIST KHP Cat. #11673 0.250 mg/l C NIST KHP Cat. #11678 0.500 mg/l C NIST KHP Cat. #11726 0.750 mg/l C NIST KHP Cat. #11781 1.00 mg/l C NIST KHP Cat. #11801 2.00 mg/l C NIST KHP Cat. #12101 5.00 mg/l C NIST KHP Cat. #12401 8.00 mg/l C NIST KHP Cat. #12602 10.0 mg/l C NIST KHP Cat. #12701 25.0 mg/l C NIST KHP Cat. #13001 50.0 mg/l C NIST KHP Cat. #13224 100 mg/l C NIST KHP Cat. #13273 Rw-Reagent Water USP Cat. #18006 Rs-0.500 mg/l C from USP Sucrose Cat. #18007 Rss-0.500 mg/l C from USP 1,4-Benzoquinone Cat. #18008 System Suitability Sets Each system suitability set contains (1) Reagent Water Rw, (1) 0.500 mg/l C from USP Sucrose Rs and (1) 0.500 mg/l C from USP 1,4-benzoquinone Rss. 250 ml Bulk CRMs TOC/IC Calibration Blank Cat. #10026 0.050 mg/l C NIST KHP Cat. #11668 0.100 mg/l C NIST KHP Cat. #11675 0.250 mg/l C NIST Sucrose Cat. #10322 0.500 mg/l C NIST KHP Cat. #11736 0.500 mg/l C NIST Sucrose Cat. #10622 0.750 mg/l C NIST KHP Cat. #11791 0.750 mg/l C NIST Sucrose Cat. #10922 1.00 mg/l C NIST KHP Cat. #11821 2.00 mg/l C NIST KHP Cat. #12121 2.50 mg/l C NIST KHP Cat. #13336 5.00 mg/l C NIST KHP Cat. #12421 10.0 mg/l C NIST KHP Cat. #12721 25.0 mg/l C NIST KHP Cat. #13041 50.0 mg/l C NIST KHP Cat. #13229 100 mg/l C NIST KHP Cat. #13272 250 mg/l C NIST KHP Cat. #13313 400 mg/l C NIST KHP Cat. #13314 1000 mg/l C NIST KHP Cat. #13306 2000 mg/l C NIST KHP Cat. #13309 Rw-Reagent Water USP Cat. #18046 Rs-0.500 mg/l C from USP Sucrose Rs Cat. #18047 Rss-0.500 mg/l C from USP Benzoquinone Cat. #18048 500 ml Bulk Standards USP System Suitability Set - 40 ml Cat. #18004 System Suitability Set - 125 ml Cat. #18024 System Suitability Set - 250 ml Cat. #18049 System Suitability Set - 500 ml Cat. #18104 System Suitability Set - 1 Liter Cat. #18204 125 ml Bulk CRMs TOC/IC Calibration Blank Cat. #10016 0.050 mg/l C NIST KHP Cat. #11667 0.100 mg/l C NIST KHP Cat. #11674 0.500 mg/l C NIST KHP Cat. #11731 0.750 mg/l C NIST KHP Cat. #11786 1.00 mg/l C NIST KHP Cat. #11811 5.00 mg/l C NIST KHP Cat. #12411 10.0 mg/l C NIST KHP Cat. #12711 15.0 mg/l C NIST KHP Cat. #12902 25.0 mg/l C NIST KHP Cat. #13021 50.0 mg/l C NIST KHP Cat. #13227 100.0 mg/l C NIST KHP Cat. #13274 1000 mg/l C NIST KHP Cat. #13305 2000 mg/l C NIST KHP Cat. #13308 Rw-Reagent Water USP Cat. #18029 Rs-0.500 mg/l C from USP Sucrose Rs Cat. #18031 Rss-0.500 mg/l C from USP Benzoquinone Cat. #18032 TOC/IC Calibration Blank Cat. #10101 0.100 mg/l C NIST KHP Cat. #11676 0.250 mg/l C NIST Sucrose Cat. #10401 0.500 mg/l C NIST KHP Cat. #11751 0.500 mg/l C NIST Sucrose Cat. #10701 0.750 mg/l C NIST KHP Cat. #11796 0.750 mg/l C NIST Sucrose Cat. #11001 1.00 mg/l C NIST KHP Cat. #11901 2.00 mg/l C NIST KHP Cat. #12201 5.00 mg/l C NIST KHP Cat. #12501 10.0 mg/l C NIST KHP Cat. #12801 25.0 mg/l C NIST KHP Cat. #13101 50.0 mg/l C NIST KHP Cat. #13231 1000 mg/l C NIST KHP Cat. #13307 2000 mg/l C NIST KHP Cat. #13310 Rw-Reagent Water USP Cat. #18105 Rs-0.500 mg/l C from USP Sucrose RS Cat. #18106 Rss-0.500 mg/l C from USP Benzoquinone Cat. #18107 42

OI Analytical, Shimadzu, Teledyne Tekmar, AJ N/C UV HS, and Lachat IL 500, Thornton 1000 ml Bulk Standards TOC/IC Calibration Blank Cat. #10201 0.100 mg/l C NIST KHP Cat. #11677 0.250 mg/l C NIST Sucrose Cat. #10501 0.500 mg/l C NIST KHP Cat. #11776 0.500 mg/l C NIST Sucrose Cat. #10801 0.750 mg/l C NIST Sucrose Cat. #11101 1.00 mg/l C NIST KHP Cat. #12001 2.00 mg/l C NIST KHP Cat. #12301 5.00 mg/l C NIST KHP Cat. #12601 10.0 mg/l C NIST KHP Cat. #12901 25.0 mg/l C NIST KHP Cat. #13201 50.0 mg/l C NIST KHP Cat. #13236 Rw-Reagent Water USP Cat. #18205 Rs-0.500 mg/l C from USP Sucrose RS Cat. #18206 Rss-0.500 mg/l C from USP 1,4-benzoquinone Cat. #18207 Sucrose CRMs 0.250 mg/l C NIST Sucrose 40 ml Cat. #10301 0.250 mg/l C NIST Sucrose 125 ml Cat. #10316 0.250 mg/l C NIST Sucrose 500 ml Cat. #10401 0.250 mg/l C NIST Sucrose 1 Liter Cat. #10501 0.500 mg/l C NIST Sucrose 40 ml Cat. #10601 0.500 mg/l C NIST Sucrose 125 ml Cat. #10616 0.500 mg/l C NIST Sucrose 250 ml Cat. #10622 0.500 mg/l C NIST Sucrose 500 ml Cat. #10701 0.500 mg/l C NIST Sucrose 1 Liter Cat. #10801 Sucrose CRMs Continued 0.750 mg/l C NIST Sucrose 40 ml Cat. #10901 0.750 mg/l C NIST Sucrose 125 ml Cat. #10916 0.750 mg/l C NIST Sucrose 250 ml Cat. #10922 0.750 mg/l C NIST Sucrose 500 ml Cat. #11001 0.750 mg/l C NIST Sucrose 1 Liter Cat. #11101 1.00 mg/l C NIST Sucrose 40 ml Cat. #11201 1.00 mg/l C NIST Sucrose 125 ml Cat. #11216 1.00 mg/l C NIST Sucrose 250 ml Cat. #11218 1.00 mg/l C NIST Sucrose 500 ml Cat. #11301 1.00 mg/l C NIST Sucrose 1 Liter Cat. #11401 Thornton Thornton 5000 System Suitability Set Cat. #18151 USP Reagent Water Blank (Rw) for 5000 TOC (unpr) - 500 ml Cat. #18144 0.500 mg/l C from USP Sucrose (Rs) for Thornton 5000 TOC (unpr) - 500 ml Cat. #18145 0.500 mg/l C from USP 1,4-benzoquinone Cat. #18146 Thornton 5000 Calibration Kit Cat. #11414 Reagent Water Blank (Thornton) Cat. #11411 0.250 mg/l C NIST Sucrose (Thornton) Cat. #11412 0.500 mg/l C NIST Sucrose (Thornton) Cat. #11413 Please see page 20 for Thornton product descriptions. From left to right: Ellen LaRiviere, Customer Service Representative; Pat Maloney, Customer Service Representative; Brian Stringer, Customer Service Representative; Audrey Cornell, Customer Service Representative; GG Galarneau, Director of Operations TOC CRMs BY MANUFACTURER web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 43

INDEX 44 Index A A643... 9, 10, 38 Accredition...4 Ammonium Persulphate...14, 16-19 Analytik Jena...15, 41-43 Anatel...9, 10,11 ASTM Conductivity Solutions...22-25 Aurora, OI... 16 B Buffers, ph... 35 Bulk Reagents... 35 Bulk TOC CRMs...9-20, 38-43 C Cleaning Validation...26-29 Conductivity...22-25 Coupons... 28 CRMs...4, 9-20 Custom Products... 34 E EDTA... 35 EP 2.2.38... 23, 24 EP 2.2.44... 7, 9-20, 38-43 F Fusion, Tekmar...18-19 H H 2 SO 4... 35 Hach Ultra... 9, 10, 38 HCl... 35 Hydrochloric Acid... 35 I IC CRMs... 21 Inorganic Carbon... 21 ISO Guide 34...4 K KOH... 35 M Model 400, Sievers... 12 Model 500, Sievers... 12 Model 900, Sievers...13-14 N NaHCO 3... 21 NaOH... 35 O OI Analytical... 16 P PAT 700... 9, 10, 38 PH Buffers... 35 Phoenix, Tekmar...18-19 Phosphoric Acid...13-14, 35 Potassium Hydroxide... 35 Pump tubing... 14 Purified Water... 36 R Reagents, Bulk... 35 Reagents, TOC...13-19 Residual Solvents... 34 S Sample Bottles... 31 Sampling Kits... 29 Shimadzu... 17 Sievers...12-14 Sodium Hydroxide... 35 Sulfuric Acid... 35 Swabbing Templates... 27 Swabs... 27 System Suitability Test... 7, 9-20, 38-43 T Tekmar...18-19 Teledyne...18-19 Thornton... 20 TOC Vials... 31 TOC/IC CRMs... 21 TOC-free Water... 36 Turbidity... 33 U Uncertainty...4 USP 467... 34 USP 643... 7, 9-20, 38-43 USP 645... 23, 24 UV lamps... 9-20 V Vials... 31

Austria PMT Partikel-Messtechnik GmbH Email: info@omt.de Website: www.omt.eu Phone: 49 (0)7033 5374-0 Fax: 49 (0)7033 5374-57 Azerbaijan BLG Kimya Teknolojileri Email: info@blgkimya.com Website: www.blgkimya.com Phone: 90 216 455 43 71 / 72 Fax: 90 216 455 43 73 Belgium PMV Belgium bvba Email: info@pmv.be Website: www.pmv.be Phone: 32 (0) 3 292 88 11 Fax: 32 (0) 3 292 88 19 Brazil Cromatec Email: roberto@cromatec.com.br Website: www.cromatec.com.br Phone: 11 5670 2530 Fax: 11 5670 2510 Canada Pegram Technologies Inc Email: bruceglover@pegram.ca Website: www.pegram.ca Phone: 416 766 9171 Ecuador Dr. J. David Saldarreaga M. Email: jdsaldarreaga@yahoo.com.mx Phone: 593 2 2432269 Estonia Prokvali Oy Website: www.prokvali.fi Email: jari.sandholm@prokvali.fi Phone: 358(0) 50 070 5932 Finland Prokvali Oy Website: www.prokvali.fi Email: jari.sandholm@prokvali.fi Phone: 358(0) 50 070 5932 France PMT France SAS Email: contact@pmtfrance.fr Website: www.pmtfrance.fr Phone: 01 64 55 13 00 Fax: 01 64 55 13 01 Georgia BLG Kimya Teknolojileri Email: info@blgkimya.com Website: www.blgkimya.com Phone: 90 216 455 43 71 / 72 Fax: 90 216 455 43 73 Germany PMT Partikel-Messtechnik GmbH Website: www.pmt.eu Phone: 49 (0)7033 5374-0 Fax: 49 (0)7033 5374-57 Greece Malva S. A. Email: info@malva.gr Website: www.malva.gr Phone: 30 210 8000904 Fax: 30 210 8001424 Hungary PCT Kft Email: pct@pct.hu Phone: 36 96 237 199 Fax: 36 96 576 224 Ireland Focus Scientific Solutions Email: info@focusscientific.ie Website: www.focusscientific.ie Phone: 353 1 883 4964 Fax: 353 1 883 4968 Italy AMIRA SRL Email: info@amirasrl.com Website: www.amirasrl.com Phone: 0039 0362 528178 Fax: 0039 0362 919596 Iraq BLG Kimya Teknolojileri Email: info@blgkimya.com Website: www.blgkimya.com Phone: 90 216 455 43 71 / 72 Fax: 90 216 455 43 73 Kazakhstan BLG Kimya Teknolojileri Email: info@blgkimya.com Website: www.blgkimya.com Phone: 90 216 455 43 71 / 72 Fax: 90 216 455 43 73 Kyrgyzstan BLG Kimya Teknolojileri Email: info@blgkimya.com Website: www.blgkimya.com Phone: 90 216 455 43 71 / 72 Fax: 90 216 455 43 73 Latvia Prokvali Oy Website: www.prokvali.fi Email: jari.sandholm@prokvali.fi Phone: 358(0) 50 070 5932 Lithuania Prokvali Oy Website: www.prokvali.fi Email: jari.sandholm@prokvali.fi Phone: 358(0) 50 070 5932 Mexico Groupo iis, Grupo Interdisciplinario de Ingeniería y Servicios Email: thernandez@grupoiis.com Website: www.grupoiis.com Phone: 52 55 53585720 Netherlands LPS b.v. Email: John.Murphy@lps.nl Website: www.lps.nl Phone: 0031 73 5219200 Fax: 0031 73 5220657 PMV bv Email: info@pmvbv.nl Website: www.pmvbv.nl Phone: 31 (0) 412 669633 Fax: 31 (0) 412 669630 Puerto Rico FIS-VCI, Inc. Email: tmorales@fis-vci.com Website: www.fis-vci.com Phone: 787 289 0560 Fax: 787 289 0567 For all other inquiries, visit www.eraqc.com ERA Distributors Portugal Type Solution Website: www.typesolution.pt Phone: 351 309 995 508 Fax: 351 309 995 509 Romania MUSO S.R.L. Email: jean.negru@muso.ro Website: www.muso.ro Phone: 40 21 323 0667 Fax: 40 21 323 0667 Slovakia CHROMSPEC-SLOVAKIA, Email: chromspec@chromspec.sk Website: www.chromspec.sk Phone: 421 31 7707994 or 5 Fax: 421 31 7712155 Tajikistan BLG Kimya Teknolojileri Email: info@blgkimya.com Website: www.blgkimya.com Phone: 90 216 455 43 71 / 72 Fax: 90 216 455 43 73 Turkey BLG Kimya Teknolojileri Email: info@blgkimya.com Website: www.blgkimya.com Phone: 90 216 455 43 71 / 72 Fax: 90 216 455 43 73 Turkmenistan BLG Kimya Teknolojileri Email: info@blgkimya.com Website: www.blgkimya.com Phone: 90 216 455 43 71 / 72 Fax: 90 216 455 43 73 Uruguay DEXIN Email: cmorato@dexin.com.uy Website: www.dexin.com.uy Phone: 598 2 5076058 Uzbekistan BLG Kimya Teknolojileri Email: info@blgkimya.com Website: www.blgkimya.com Phone: 90 216 455 43 71 / 72 ERA Distributors web WWW.ERAQC.COM US P. 800-554-2511 (or) 303-431-8454 P. +44 (0) 161 944 2777 EU 45

Customer Care Customer Care We are here to help! We have customer service, manufacturing and shipping personnel here to help you, U.S. from 6:00 am - 6:00 pm (MT) Monday-Thursday; 6:00 am - 5:00 pm (MT) Friday, and Europe from 8:00 am to 5:00 pm (GMT). If you want the standard tomorrow, just call us by 4:00 pm MT (U.S.) or 1:00 pm GMT (Europe) and you will have your standards the next day in most cases. We are ISO 9001 registered and comply with all applicable technical, quality and regulatory requirements. Call 1-800-554-2511 (U.S.) or 44 (0) 161 946 2777 (Europe) or e-mail us at info@eraqc.com and we will confirm your order by e-mail the same day. Isabelle De Leon, Receptionist Think of ERA as your stockroom for TOC and Cleaning Validation products. Let us know what you need and when you need it, and we will take care of the rest. We deliver product around the world, shipping hundreds of packages per week between our Golden, Colorado, US and Manchester, UK manufacturing facilities. We understand the importance of delivering our products promptly and reliably and that s why we work with two preferred couriers FedEx and UPS. Same day shipping is available on most products (except customs). For orders received before 4:00 pm MT in the US and 2:00 pm GMT in the UK (Mon-Thurs), you will receive them the next day. 46