Feline reference intervals for the Sysmex XT-2000iV and the ProCyte DX haematology analysers in EDTA and CTAD blood specimens

Similar documents
LEEK DIET MAY CAUSE HEMOLYTIC ANEMIA: A CASE REPORT IN A CAT

Rate of manual leukocyte differentials in dog, cat and horse blood samples using ADVIA 120 cytograms

Blood Cell Characteristics and Some Hematological Values of American Pit-bull Terriers in Thailand

Blood Cells of Reptiles. Blood Cells of Reptiles. Blood Cells of Reptiles. Blood Cells of Reptiles. Blood Cells of Reptiles

EHRLICHIOSIS IN DOGS IMPORTANCE OF TESTING FOR CONTRIBUTING AUTHORS CASE 1: SWIGGLES INTRODUCTION WITH PERSISTENT LYMPHOCYTOSIS

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE VSCT 202 VETERINARY CLINICAL PATHOLOGY II

Survey of point-of-care instrumentation, analysis, and quality assurance in veterinary practice

Exotic Hematology Lab Leigh-Ann Horne, LVT, CWR Wildlife Center of Virginia

Supplementary figure 1: Questionnaire used to establish the constitution of the patient (relevant characteristics of the whole patient leading to the

The effect of age on haematological studies in ostrich (Struthio camelus)

Further Enhancing the Woodley Veterinary Diagnostics product range

MURDOCH RESEARCH REPOSITORY

HAEMATOLOGICAL PROFILE IN HALLIKAR CATTLE AT THE NATIVE TRACT

ASVCP guidelines: quality assurance for point-of-care testing in veterinary medicine

Australian and New Zealand College of Veterinary Scientists. Membership Examination. Veterinary Pathology Paper 1

Pierre-Louis Toutain, Ecole Nationale Vétérinaire National veterinary School of Toulouse, France Wuhan 12/10/2015

PERSISTENT EXCESSIVE THROMBOCYTHAEMIA IN A CAT

Australian and New Zealand College of Veterinary Scientists. Membership Examination. Medicine of Horses Paper 1

Serological Prevalence of FeLV and FIV in Cats in Peninsular Malaysia

Copyright is owned by the Author of the thesis. Permission is given for a copy to be downloaded by an individual for the purpose of research and

EXOTIC CLINICAL PATHOLOGY

Journal home page:

ASVCP quality assurance guidelines: veterinary immunocytochemistry (ICC)

Breed effects on biochemical variables have been reported

Comparative Evaluation of Online and Paper & Pencil Forms for the Iowa Assessments ITP Research Series

Feline blood transfusions: preliminary considerations

Haematological studies of donkeys in Sokoto state, Nigeria

Australian and New Zealand College of Veterinary Scientists. Membership Examination. Veterinary Anaesthesia and Critical Care Paper 1

A Simply Smart Choice for Point-of-Care Testing

Module C Veterinary Pathology Clinical Pathology - Laboratory Diagnostics (C-VP.2)

AUSTRALIAN AND NEW ZEALAND COLLEGE OF VETERINARY SCIENTISTS. Sample Exam Questions. Veterinary Practice (Small Animal)

Hematologic Parameters of Captive Lions (Panthera leo) and Siberian Tigers (Panthera tigris altaica)

Top Gun Phlebotomy. Pseudohyperkalemia 9/10/2018. HOT TOPIC / Phlebotomy Top Gun, Pseudohyperkalemia HOT TOPIC / 2018

Introduction SPECIAL REPORT

A Comparison of Pyronin Y-Methyl Green Stain and Methylene Blue Stain for Somatic Cell Count in Sheep Milk

Page Proof Instructions and Queries

Xenotransfusion with canine blood in the feline species: review of the literature

PROCEEDINGS OF THE NORTH AMERICAN VETERINARY CONFERENCE VOLUME 20 JANUARY 7-11, 2006 ORLANDO, FLORIDA

STAT170 Exam Preparation Workshop Semester

The Comparative Study of the Blood Cellular Composition in Muscovy Ducks in Nigeria

Syringe and aggregate filter administration does not affect survival of transfused autologous fresh feline red blood cells

A retrospective study of 180 anaemic cats: features, aetiologies and survival data

MEETING OF THE ICAR WORKING GROUP ON MILK RECORDING OF SHEEP. Draft minutes

DETERMINATION OF PLASMA BIOCHEMISTRIES, IONIZED CALCIUM, VITAMIN 03, AND HEMATOCRIT VALUES IN CAPTIVE GREEN IGUANAS (Iguana iguana) FROM EI SALVADOR

Evaluation of the hair growth and retention activity of two solutions on human hair explants

Clinicopathologic and electrocardiographic features of Akita dogs with high and low erythrocyte potassium phenotypes

////////////////////////////////////////// Shelter Medicine

FIV/FeLV testing FLOW CHARTS

STATISTICAL REPORT. Preliminary Analysis of the Second Collaborative Study of the Hard Surface Carrier Test

Risk factors for canine cognitive dysfunction syndrome in Slovakia

5/3/2018 3:09 AM Approved (Changed Course) ANHLT 151 Course Outline as of Fall 2017

Antimicrobial practice. Laboratory antibiotic susceptibility reporting and antibiotic prescribing in general practice

Nathan A. Thompson, Ph.D. Adjunct Faculty, University of Cincinnati Vice President, Assessment Systems Corporation

Rapid Diagnostic Test for pet

PREVENTIVE HEALTHCARE PROTOCOLS: SIMPLIFIED

COMMITTEE FOR VETERINARY MEDICINAL PRODUCTS

Color: Black/Tan NO GROWTH ON SOLID MEDIA IN 48 HRS. NO GROWTH ON SOLID MEDIA IN 24 HRS.

EXPERIMENTAL STUDY OF CHRONIC IRON DRUGS TOXICITIES IN ANEMIC EWES

Airport Animal Hospital 4259 Haines Rd Duluth, MN (218) /24/2017. Shadow

Evaluation of frequency and intensity of asymptomatic anisocytosis in the Japanese dog breeds Shiba, Akita, and Hokkaido

Title: Antibacterial resistances in uncomplicated urinary tract infections in women: ECO * SENS II data from primary health care in Austria

ECVCP Reading List. Recommendations of the examination committee 2017

Double-Blind, Placebo-Controlled, Randomized Study of Dipyrone as a Treatment for Pyrexia in Horses

Suggested vector-borne disease screening guidelines

Copyright is owned by the Author of the thesis. Permission is given for a copy to be downloaded by an individual for the purpose of research and

Australian and New Zealand College of Veterinary Scientists. Membership Examination. Veterinary Emergency and Critical Care Paper 1

Australian and New Zealand College of Veterinary Scientists. Membership Examination. Medicine of Cats Paper 1

EVALUATION OF HEMATOLOGIC VALUES IN FREE- RANGING AFRICAN BUFFALO (SYNCERUS CAFFER)

timorensis Malaysian Journal of Veterinary Research Volume 3 No. 2 JULY 2012 pages 29-34

Rosenberger et al.: Capercaillie eggshell pigmentation, maculation and thickness

GUIDELINES. Ordering, Performing and Interpreting Laboratory Tests in Veterinary Clinical Practice

JEFFERSON COLLEGE COURSE SYLLABUS VAT114 PRINCIPLES OF CLINICAL MEDICINE II. 4 Credit Hours

Mature lymphocytosis (ie, 7,000/ L) in the blood of

The Friends of Nachusa Grasslands 2016 Scientific Research Project Grant Report Due June 30, 2017

BACTERIOLOGY. Microscopic agglutination test (MAT) for one sample 5 (for a maximum of 5 antigens)

CERTIFIED REFERENCE MATERIAL IRMM 313

SOP: Blood Collection in the Horse

Diagnosis of feline haemoplasma infection using a real-time PCR assay

An Estimate of the Number of Dogs in US Shelters. Kimberly A. Woodruff, DVM, MS, DACVPM David R. Smith, DVM, PhD, DACVPM (Epi)

Tick-borne Disease Testing in Shelters What Does that Blue Dot Really Mean?

Hematology and serum biochemistry of captive gharial (Gavialis gangeticus) in India

ECVCP Reading List. Suggested studying guide for preparation for the certifying examination of the ECVCP

Presenting Complaint: Her owners were concerned because she seemed to be losing weight despite having a

Critical appraisal Randomised controlled trial questions

Active Bacterial Core Surveillance Site and Epidemiologic Classification, United States, 2005a. Copyright restrictions may apply.

Inside This Issue. BEYOND numbers

SAFETY PHARMACOLOGY: CARDIOVASCULAR TELEMETRY. Aileen Milne PhD, Manager, Safety Pharmacology

Are Dogs That Are Fed from a Raised Bowl at an Increased Risk of Gastric Dilation Volvulus Compared with Floor-Fed Dogs?

Outline Animal Welfare Series Caring for the Senior Pet

Correspondence should be addressed to M. Veeraselvam;

RESULTS FROM THE CURRENT POPULATION SURVEY CATI PHASE-IN PROJECT. Harland H. Shoemaker, Jr. U.S. Bureau of the Census Washington, DC 20233

DOES TIMING OF ANTIBIOTICS IMPACT OUTCOME IN SEPSIS? Saravana Kumar MD HEAD,DEPT OF EM,DR MEHTA S HOSPITALS CHENNAI,INDIA

European Regional Verification Commission for Measles and Rubella Elimination (RVC) TERMS OF REFERENCE. 6 December 2011

PCR detection of Leptospira in. stray cat and

Changing Trends and Issues in Canine and Feline Heartworm Infections

Claw lesions as a predictor of lameness in breeding sows Deen, J., Anil, S.S. and Anil, L. University of Minnesota USA

FELINE CORONAVIRUS (FCoV) [FIP] ANTIBODY TEST KIT

G-TwYST GMP Two Year Safety Testing. WP 3 Feeding trials. Dagmar Zeljenková, Jana Tulinská Slovak Medical University Bratislava.

Section: 101 (2pm-3pm) 102 (3pm-4pm)

THE VETERINARIAN'S CHOICE. Compendium clinical Trials. Introducing new MILPRO. from Virbac. Go pro. Go MILPRO..

Transcription:

511811JFM16610.1177/1098612X13511811Journal of Feline Medicine and SurgeryGranat et al 2013 Original Article Feline reference intervals for the Sysmex XT-2000iV and the ProCyte DX haematology analysers in EDTA and CTAD blood specimens Journal of Feline Medicine and Surgery 2014, Vol. 16(6) 473 482 ISFM and AAFP 2013 Reprints and permissions: sagepub.co.uk/journalspermissions.nav DOI: 10.1177/1098612X13511811 jfms.com Fanny Granat 1, Anne Geffré 1, Nathalie Bourgès-Abella 2, Jeremy Mortier 1, Marie-Laure Théron 1, Emilie Fauchon 1, Jean-Pierre Braun 1 and Catherine Trumel 1 Abstract Laser-based haematology analysers are routinely used in veterinary clinical pathology laboratories, and are available to practitioners. However, feline haematological reference intervals (RIs) determined according to international recommendations are, to our knowledge, not available. Furthermore, platelet count RI is difficult to establish in cats because of the frequent occurrence of platelet aggregation in blood specimens. The purpose of this study was to establish feline haematological RIs with the Sysmex XT-2000iV and ProCyte DX analysers, in ethylenediamine tetra-acetic acid (EDTA) and in citrate, theophylline, adenosine and dipyridamole (CTAD), which is a combination of anticoagulants limiting platelet aggregation. Blood specimens from 120 healthy cats were analysed in duplicate, and the degree of platelet aggregation was assessed on blood smears. After exclusion of inadequate specimens, 81 sets of results (from 44 males and 37 females, aged from 6 to 116 months) were available for the determination of RIs by the non-parametric method. The effects of the anticoagulant, analyser and aggregation score were assessed. When the aggregation effect was significant, the RIs were determined using the subgroup of blood specimens with no or little aggregation. The effects of sex, age and weight were also investigated, but were moderate. The different RIs obtained with the Sysmex XT-2000iV and ProCyte DX analysers, and the two anticoagulants, were very similar to previous RIs established in EDTA with the ADVIA 120, another laser-based analyser, except for the platelet count in CTAD specimens. Its lower reference limit was higher in CTAD vs EDTA specimens, which confirms the interest in this anticoagulant in cats. Accepted: 14 October 2013 Introduction Specific reference intervals (RIs) are essential to interpret clinical data in veterinary medicine. RIs are specific to a clearly defined population and to the analyser used to perform the analysis. To our knowledge, there is only one report describing haematology feline reference values by flow cytometric analysis, with the ADVIA 120 analyser (Bayer), based on 61 ethylenediamine tetraacetic acid (EDTA) feline blood specimens. 1 To our knowledge, no RIs have been established in cats for two other frequently used blood analysers: the Sysmex XT-2000iV (Sysmex), a reference laboratory haematology analyser, and the ProCyte DX (IDEXX Laboratories), an in-house haematology analyser. The few studies on haematological RIs in cats might be due to the difficulty of obtaining a good blood specimen, especially without platelet clumping. Correct blood sampling has been shown to be facilitated by use of a microtube system to reduce stress and the sampled volume (about 200500 1 Department of Clinical Sciences, University of Toulouse, Institut National Polytechnique Ecole Nationale Vétérinaire de Toulouse (INP-ENVT), France 2 Department of Functional and Biological Sciences, University of Toulouse, Institut National Polytechnique Ecole Nationale Vétérinaire de Toulouse (INP-ENVT), France Corresponding author: Fanny Granat DVM, Department of Clinical Sciences, University of Toulouse, Institut National Polytechnique Ecole Nationale Vétérinaire de Toulouse (INP-ENVT) 23 chemin des Capelles, BP 87614, 31076 Toulouse, France Email: f.granat@envt.fr

474 Journal of Feline Medicine and Surgery 16(6) µl). 2 It has also been demonstrated that platelet aggregation can be limited for at least 48 h by using a combination of citrate, theophylline, adenosine and dipyridamole (CTAD) alone or added to classic EDTA tubes. 35 The objective of this study was to establish the RIs of feline blood specimens collected in EDTA and CTAD microtubes for the Sysmex XT-2000iV and the ProCyte DX haematology systems, in accordance with the guidelines of the American Society of Veterinary Clinical Pathology (ASVCP), the International Federation of Clinical Chemistry (IFCC), and the Clinical and Laboratory Standards Institute (CLSI). 6,7 Materials and methods This prospective study was performed between October 2010 and July 2011 at the Laboratoire Central de Biologie Médicale of the Veterinary School of Toulouse. The experimental protocol was designed according to ASVCP and IFCCCLSI guidelines on the de novo establishment of RIs. 6,7 The initial aim was to collect at least 120 feline blood specimens. Unfortunately, owing to some analytical difficulties and the a posteriori exclusion of certain specimens, 81 results were finally available for RI determination. However, this number conformed with the IFCCCLSI recommendation that if a laboratory has adequate statistical and computing competence, the working group encourages consideration of procedures that do not require 120 individuals to estimates reference limits and confidence interval. 7 Inclusion and exclusion criteria The cats included in the study had been presented at the preventive medicine department of the Veterinary School of Toulouse for vaccination, the owners requiring screening of their cats for retroviral infection, that is, feline leukemia virus (FeLV) and feline immunodeficiency virus (FIV). Before sampling, all owners signed an informed consent to allow the use of the blood specimen for this study. Inclusion criteria were as follows: cats older than 6 months and healthy based on a detailed questionnaire (including queries about vaccination status, fasted condition, general behaviour, history of previous illness and treatments), and a complete physical examination performed by an experienced clinician. Cats were excluded a priori if any of the following were present: lactation, history of diseases or surgery within the last month, any treatment within the last month except for external antiparasitic treatment, any abnormality found during the physical examination, and a positive result for FeLV or FIV (Rapid FIV Ab, FeLV Ag; Kitvia). Specimen collection Blood was collected without sedation in a quiet environment and with minimal restraint. Venipuncture was performed in the cephalic vein with a 23 gauge needle (0.6 25 mm: 23GNeolus; Terumo Europe), a microcapillary (microcapillary system EDTA 200 µl; Microvette, Sarstedt) and a microtube. The EDTA microtubes (0.5 ml K3EDTA: Minicollect; Greiner Bio- One) were ready prepared, whereas the CTAD microtubes were prepared just before each sampling by adding 50 µl of CTAD solution to dry microtubes (0.5 ml: Z No additive Minicollect; Greiner Bio-One). The CTAD and EDTA microtubes were filled in a randomised order determined by coin tossing. Tubes were gently homogenised by 10 inversions immediately after specimen collection. Incorrectly filled tubes (> ± 5% error) or tubes with macroscopic clots were excluded. The microtubes were then placed for 20 mins on a mechanical mixer (Speci Mix, CT06478; Drew) before being processed within 1 h of sampling. A semi-quantitative method of scoring, ranging from 1 to 5 (low to high difficulty), was used to evaluate sampling [difficulty in filling the microtubes (direct vs interrupted flow, slow vs quick flow) and stress of the cats as perceived by the phlebotomist]. Haematological analyses Complete blood cell counts (CBCs) were obtained with both the Sysmex XT-2000iV and ProCyte DX analysers. Quality controls were performed with the manufacturers control solutions (Sysmex e-check L2 for the Sysmex XT-2000iV and ProCyte DX QC levels 1 and 2 for the ProCyte DX). Duplicate analyses of each tube were performed with both analysers in a randomised order determined by coin tossing. The CBC obtained with the Sysmex XT-2000iV analyser (with the software version 00-10 Sysmex and the corresponding species settings), included white blood cell (WBC) count, red blood cell (RBC) count (RBC-I: RBC count by impedance measurement; RBC-O: RBC count by optical measurement), platelet (PLT) count (PLT-I: PLT count by impedance measurement; PLT-O: PLT count by optical measurement), haemoglobin (HGB), haematocrit (HTE), mean corpuscular volume (MCV), mean corpuscular haemoglobin (MCH), mean corpuscular haemoglobin concentration (MCHC), RBC distribution width as a percentage (RDW-CV), RBC distribution width as a coefficient of variation (RDW-SD), reticulocyte percentage (RET % ) and reticulocyte count (RET c ), the reticulocyte indexes [low fluorescence ratio (LFR), medium fluorescence ratio (MFR), high fluorescence ratio (HFR) and immature reticulocyte fraction (IRF)] and the leukocyte differential count. Analyses performed by the ProCyte DX (with the software version 00-25-18) included WBC, RBC-I, PLT-O, HGB, HTE, MCV, MCH, MCHC, RDW-CV, RET % and RET c, and the leukocyte differential count. The basophil count has never been validated with any analyser in feline blood specimens,

Granat et al 475 and was not examined here. 8,9 The results for the CTAD tubes were multiplied by a factor (1.1) to compensate for dilution of HGB, RBC, HTE, WBC, neutrophil count, lymphocyte count, monocyte count, eosinophil count, PLT and RET c. Two blood films were prepared from each EDTA and CTAD tube. The blood films were air-dried and stained with modified MayGrünwaldGiemsa (Aerospray Haematology Slide Stainer Cytocentrifuge 7150; Wescor), fixed, coverslip-mounted and stored in darkness. The blood films were retrospectively examined by the same trained veterinarian under light microscopy (BX60 microscope WH10X/22; Olympus) to estimate the score of platelet aggregation (SPA-F) according to Norman et al, 3 as previously described. 4,5 They were then classified as not or little aggregated (NLA) vs highly aggregated (HA) at the arbitrary previously used threshold SPA-F < 2 vs 2, respectively. 4,5 Data analyses The distribution of each variable was first inspected visually to check for normality and possible outliers. The latter were tested by Dixon s criterion and the eliminated values are reported in the footnotes to Tables 14. Normality was then tested by AndersonDarling test. Reference limits were determined by the non-parametric method and their 90% confidence interval (CI) by a bootstrap method. Possible effects of the analyser (Sysmex Table 1 Reference intervals for feline specimens collected in EDTA and determined with the ProCyte DX analyser Analyte SPA-F group n Normality, P Median and range Mean 2.5th 97.5th WBC NLA + HA 80 a 0.082 8.7 3.817.2 Neutrophils NLA + HA 80 0.000 3.2 1.510.8 Lymphocytes NLA + HA 80 0.019 4.3 1.210.4 Monocytes NLA + HA 79 b, 0.024 0.3 0.10.7 Eosinophils NLA + HA 76 c,d,e,f, 0.007 0.5 0.11.2 RBC-I NLA + HA 81 0.035 9.7 ( 10 12 /l)* 6.511.5 HGB (g/l) NLA 40 0.726 130.3 94.0161.5 HTE (l/l) NLA 40 0.458 0.39 0.300.55 MCV (fl) NLA + HA 81 0.246 43.6 37.256.3 MCH (pg) NLA + HA 81 0.064 14.0 11.816.5 MCHC (g/dl) NLA + HA 81 0.550 32.0 27.335.2 RDW-CV (%) NLA + HA 81 0.055 24.6 19.734.7 RET NLA + HA 80 g 0.000 16.0 2.048.9 RET (%) NLA + HA 80 h 0.000 0.2 0.00.7 PLT-O NLA 40 0.358 286 86615 9.1 4.0 (3.8; 4.6) 3.7 1.7 (1.5; 1.8) 4.4 1.2 (1.2; 1.5) 0.3 0.1 (0.1; 0.1) 0.6 0.1 9.6 6.7 (6.5; 7.7) 129.0 94.1 (94.0; 106.5) 0.40 0.30 (0.30; 0.33) 43.5 37.3 (37.2; 38.0) 13.9 12.0 (11.8; 12.2) 32.0 28.8 (27.3; 29.8) 24.9 20.2 (19.7; 21.9) 18.1 3.8 (2.0; 4.7) 0.2 0.0 (0.0; 0.1) 281 87 (86; 154) 15.2 (14.0; 17.2) 8.8 (7.5; 10.8) 10.2 (8.1; 10.4) 0.6 (0.5; 0.7) 1.2 (1.0; 1.2) 11.2 (11.1; 11.5) 161.4 (153.9; 161.5) 0.54 (0.49; 0.55) 52.6 (50.2; 56.3) 15.8 (15.4; 16.5) 34.9 (34.0; 35.2) 30.2 (29.4; 34.7) 48.6 (42.8; 48.9) 0.5 (0.4; 0.7) 610 (437; 615) SPA-F = score of platelet aggregation; CI = confidence interval; WBC = white blood cells; RBC-I = red blood cell count by impedance measurement; HGB = haemoglobin; HTE = haematocrit; MCV = mean corpuscular volume; MCH = mean corpuscular haemoglobin; MCHC = MCH concentration; RDW-CV = red blood cell distribution width as a percentage; RET = reticulocytes; PLT-O = platelet count by optical measurement; NLA = not or little aggregated; HA = highly aggregated Outliers: a 24.5 10 9 /l; b 1.2 10 9 /l; c 1.83 10 9 /l; d 1.62 10 9 /l; e 1.67 10 9 /l; f 1.62 10 9 /l; g 86.9 10 9 /l; h 0.8% *No effect of analyser and anticoagulant One missing datum

476 Journal of Feline Medicine and Surgery 16(6) Table 2 Reference intervals for feline specimens collected in CTAD and determined with the ProCyte DX analyser Analyte SPA-F group n Normality, P Median and range Mean 2.5th 97.5th WBC NLA + HA 80 a 0.082 8.7 3.817.2 Neutrophils NLA + HA 80 0.000 3.2 1.510.8 Lymphocytes NLA + HA 80 0.019 4.3 1.210.4 Monocytes NLA + HA 79 b, 0.024 0.3 0.10.7 Eosinophils NLA + HA 76 c,d,e,f, 0.007 0.5 0.11.2 RBC-I NLA + HA 81 0.035 9.7 ( 10 12 /l)* 6.511.5 HGB (g/l) NLA 80 0.657 133.4 96.3170.5 HTE (l/l) NLA 80 0.450 0.41 0.300.56 MCV (fl) NLA + HA 81 0.246 43.6 37.256.3 MCH (pg) NLA + HA 81 0.064 14.0 11.816.5 MCHC (g/dl) NLA + HA 81 0.550 32.0 27.335.2 RDW-CV (%) NLA + HA 80 g 0.231 23.6 19.730.2 RET NLA + HA 80 h 0.000 16.0 2.048.9 RET (%) NLA + HA 80 i 0.000 0.2 0.00.7 PLT-O NLA 80 0.042 288 130601 9.1 4.0 (3.8; 4.6) 3.7 1.7 (1.5; 1.8) 4.4 1.2 (1.2; 1.5) 0.3 0.1 (0.1; 0.1) 0.6 0.1 9.6 6.7 (6.5; 7.7) 133.0 96.9 (96.3; 109.5) 0.42 0.30 (0.30; 0.33) 43.5 37.3 (37.2; 38.0) 13.9 12.0 (11.8; 12.2) 32.0 28.8 (27.3; 29.8) 23.6 19.5 (18.2; 20.8) 18.1 3.8 (2.0; 4.7) 0.2 0.0 (0.0; 0.1) 298 139 (130; 149) 15.2 (14.0; 17.2) 8.8 (7.5; 10.8) 10.2 (8.1; 10.4) 0.6 (0.5; 0.7) 1.2 (1.0; 1.2) 11.2 (11.1; 11.5) 166.1 (157.2; 170.5) 0.55 (0.51; 0.56) 52.6 (50.2; 56.3) 15.8 (15.4; 16.5) 34.9 (34.0; 35.2) 28.7 (26.7; 29.1) 48.6 (42.8; 48.9) 0.5 (0.4; 0.7) 527 (465; 601) SPA-F = score of platelet aggregation; CI = confidence interval; WBC = white blood cells; RBC-I = red blood cell count by impedance measurement; HGB = haemoglobin; HTE = haematocrit; MCV = mean corpuscular volume; MCH = mean corpuscular haemoglobin; MCHC = MCH concentration; RDW-CV = red blood cell distribution width as a percentage; RET = reticulocytes; PLT-O = platelet count by optical measurement; NLA = not or little aggregated; HA = highly aggregated Outliers: a 24.5 10 9 /l; b 1.2 10 9 /l; c 1.8 10 9 /l; d 1.6 10 9 /l; e 1.7 10 9 /l; f 1.6 10 9 /l; g 35.1%; h 86.9 10 9 /l; i 0.8% *No effect of analyser and anticoagulant One missing datum XT-2000iV versus ProCyte DX), the order of the duplicate analysis (first vs second analysis by the same analyser), the anticoagulant (EDTA vs CTAD), the platelet aggregation score (SPA-F), age, sex and weight were tested using a general linear model analysis (significant effect was considered for P <0.05). When the observed effects of analysers, anticoagulants or SPA-F were statistically significant, the distributions were compared by Harris and Boyd s z-test. When z > z*, the RIs and 90% CI were calculated accordingly. Effects of age and weight were investigated by a regression-based analysis. 10,11 Calculations were done using Microsoft Excel, Analyse-it, Reference Value Advisor (v. 2.1) and Systat. 1214 Results Pre-analytical effects and a posteriori exclusion Thirty-nine pairs of specimens had to be excluded because of inadequate tube-filling, presence of macroscopic clots or technical mishaps regarding at least one of the two sampled tubes. Thus, only 81 pairs of specimens could be used for RI determination. The platelet aggregation score was higher in EDTA than in CTAD tubes, with 41/81 and only 1/81 HA specimens, respectively. As platelet aggregation had significant effects on certain variables, only the NLA specimens were used to determine the RIs of these latter variables. The difficulty of sampling had a significant effect on SPA-F [analysis of variance (ANOVA) P <0.05); however, the differences

Granat et al 477 Table 3 Reference intervals (RIs) for feline specimens collected in EDTA and determined with the Sysmex XT-2000iV analyser Analyte SPA-F group n Normality, P Median and range Mean 2.5th 97.5th Previously reported RIs ADVIA 120 1 2.5th97.5th s WBC NLA + HA 80 a 0.082 8.7 3.817.2 Neutrophils NLA + HA 80 0.000 3.2 1.510.8 Lymphocytes NLA + HA 80 0.019 4.3 1.210.4 Monocytes NLA + HA 79 b, 0.024 0.3 0.10.7 Eosinophils NLA + HA 76 c,d,e,f, 0.007 0.5 0.11.2 RBC-I NLA + HA 81 0.035 9.7 ( 10 12 /l)* 6.511.5 RBC-O NLA + HA 81 0.021 9.4 ( 10 12 /l) 6.311.2 HGB (g/l) NLA 40 0.356 136.3 99.0166.0 HTE (l/l) NLA + HA 81 0.511 0.39 0.290.52 MCV (fl) NLA + HA 81 0.609 41.1 34.353.2 MCH (pg) NLA + HA 81 0.176 14.6 12.317.2 MCHC (g/dl) NLA + HA 81 0.873 35.7 30.839.5 RDW-CV (%) NLA + HA 81 0.129 24.0 19.633.0 RDW-SD (fl) NLA + HA 81 0.000 28.0 24.848.1 RET NLA + HA 80 g 0.000 45.8 10.3107.8 RET (%) NLA + HA 80 h 0.000 0.5 0.11.3 IRF (%) NLA 40 0.037 6.8 0.718.8 LFR (%) NLA 40 0.037 93.2 81.399.3 MFR (%) NLA 40 0.081 5.6 0.013.9 HFR (%) NLA + HA 81 0.030 2.2 0.07.6 PLT-O NLA 40 0.358 286 86615 PLT-I NLA 40 0.233 180 33520 9.1 4.0 (3.8; 4.6) 3.7 1.7 (1.5; 1.8) 4.4 1.2 (1.2; 1.5) 0.3 0.1 (0.1; 0.1) 0.6 0.1 9.6 6.7 (6.5; 7.7) 9.2 6.6 (6.3; 7.4) 133.9 99.1 (99.0; 113.0) 0.39 0.29 (0.29; 0.33) 41.3 34.4 (34.3; 35.3) 14.5 12.3 (12.3; 12.7) 35.7 32.5 (30.8; 33.2) 24.1 19.7 (19.6; 21.0) 28.6 24.9 (24.7; 25.8) 49.7 19.1 (10.3; 24.9) 0.5 0.2 8.0 0.7 (0.7; 1.5) 92.0 81.3 (81.3; 83.6) 6.1 0.0 (0.0; 1.5) 2.3 0.0 (0.0; 0.3) 281 87 (86; 154) 189 33 (33; 76) 15.2 (14.0; 17.2) 8.8 (7.5; 10.8) 10.2 (8.1; 10.4) 0.6 (0.5; 0.7) 1.2 (1.0; 1.2) 11.2 (11.1; 11.5) 10.8 (10.5; 11.2) 165.9 (158.4; 166.0) 0.51 (0.47; 0.52) 49.3 (47.5; 53.2) 16.4 (16.1; 17.2) 39.2 (38.5; 39.5) 29.3 (27.7; 33.0) 40.6 (34.0; 48.1) 107.1 (90.3; 107.8) 1.1 (1.0; 1.3) 18.7 (16.7; 18.8) 99.3 (98.5; 99.3) 13.8 (12.6; 13.9) 5.9 (5.0; 7.6) 610 (437; 615) 516 (345; 520) 7.7318.6 3.1412.52 1.317.46 0.131.08 0.062.21 5.9211.16 8.1715.26 0.240.46 36.9654.98 11.2817.24 26.2435.91 13.8121.11 3.6694.06 0.051.17 41.92629.85 SPA-F = score of platelet aggregation; CI = confidence interval; WBC = white blood cell; RBC-I = red blood cell count by impedance measurement; RBC-O = red blood cell count by optical measurement; HGB = haemoglobin; HTE = haematocrit; MCV = mean corpuscular volume; MCH = mean corpuscular haemoglobin; MCHC = MCH concentration; RDW-CV = red blood cell distribution width as a percentage; RDW-SD = red blood cell distribution width as a coefficient of variation; RET = reticulocyte; IRF = immature reticulocyte fraction; LFR = low fluorescence ratio; MFR = medium fluorescence ratio; HFR = high fluorescence ratio; PLT-O = platelet count by optical measurement; PLT-I = platelet count by impedance measurement; NLA = not or little aggregated; HA = highly aggregated Outliers: a 24.5 10 9 /l; b 1.2 10 9 /l; c 1.8 10 9 /l; d 1.6 10 9 /l; e 1.7 10 9 /l; f 1.6 10 9 /l; g 149.5 10 9 /l; h 1.4% *No effect of analyser and anticoagulant One missing datum

478 Journal of Feline Medicine and Surgery 16(6) Table 4 Reference intervals for feline specimens collected in CTAD and determined with the Sysmex XT-2000iV analyser Analyte SPA-F group n Normality, P Median and range Mean 2.5th 97.5th WBC NLA + HA 80 a 0.082 8.7 3.817.2 Neutrophils NLA + HA 80 0.000 3.2 1.510.8 Lymphocytes NLA + HA 80 0.019 4.3 1.210.4 Monocytes NLA + HA 79 b, 0.024 0.3 0.10.7 Eosinophils NLA + HA 76 c,d,e,f, 0.007 0.5 0.11.2 RBC-I NLA + HA 81 0.035 9.7 ( 10 12 /l)* 6.511.5 RBC-O NLA + HA 81 0.021 9.4 ( 10 12 /l) 6.311.2 HGB (g/l) NLA 80 0.556 139.7 100.1177.1 HTE (l/l) NLA + HA 81 0.511 0.39 0.290.52 MCV (fl) NLA + HA 81 0.609 41.1 34.353.2 MCH (pg) NLA + HA 81 0.176 14.6 12.317.2 MCHC (g/dl) NLA + HA 81 0.445 34.8 30.438.3 RDW-CV (%) NLA + HA 81 0.094 22.8 18.432.9 RDW-SD (fl) NLA + HA 81 0.000 28.0 24.848.1 RET NLA + HA 80 g 0.000 45.8 10.3107.8 RET (%) NLA + HA 80 h 0.000 0.5 0.11.3 IRF (%) NLA 80 0.000 5.8 0.721.2 LFR (%) NLA 80 0.000 94.2 78.899.3 MFR (%) NLA 80 0.002 4.5 0.417.1 HFR (%) NLA + HA 81 0.000 1.2 0.05.3 PLT-O NLA 80 0.042 288 130601 PLT-I NLA 80 0.179 213 20535 9.1 4.0 (3.8; 4.6) 3.7 1.7 (1.5; 1.8) 4.4 1.2 (1.2; 1.5) 0.3 0.1 (0.1; 0.1) 0.6 0.1 9.6 6.7 (6.5; 7.7) 9.2 6.6 (6.3; 7.4) 138.5 103.5 (100.1; 114.0) 0.39 0.29 (0.29; 0.33) 41.3 34.4 (34.3; 35.3) 14.5 12.3 (12.3; 12.7) 34.7 31.5 (30.4; 32.4) 22.9 18.8 (18.4; 20.0) 28.6 24.9 (24.7; 25.8) 49.7 19.1 (10.3; 24.9) 0.5 0.2 6.5 1.0 (0.7; 1.4) 93.5 79.4 (78.8; 86.7) 5.2 0.5 (0.4; 0.7) 1.3 0.0 (0.0; 0.0) 298 139 (130; 149) 220 44 (20; 70) 15.2 (14.0; 17.2) 8.8 (7.5; 10.8) 10.2 (8.1; 10.4) 0.6 (0.5; 0.7) 1.2 (1.0; 1.2) 11.2 (11.1; 11.5) 10.8 (10.5; 11.2) 173.2 (161.6; 177.1) 0.51 (0.47; 0.52) 49.3 (47.5; 53.2) 16.4 (16.1; 17.2) 38.2 (37.5; 38.3) 28.1 (27.1; 32.9) 40.6 (34.0; 48.1) 107.1 (90.3; 107.8) 1.1 (1.0; 1.3) 20.6 (13.3; 21.2) 99.0 (98.6; 99.3) 16.5 (10.3; 17.1) 4.9 (4.1; 5.3) 527 (465; 601) 452 (410; 535) SPA-F = score of platelet aggregation; CI = confidence interval; WBC = white blood cell; RBC-I = red blood cell count by impedance measurement; RBC-O = red blood cell count by optical measurement; HGB = haemoglobin; HTE = haematocrit; MCV = mean corpuscular volume; MCH = mean corpuscular haemoglobin; MCHC = MCH concentration; RDW-CV = red blood cell distribution width as a percentage; RDW-SD = red blood cell distribution width as a coefficient of variation; RET = reticulocyte; IRF = immature reticulocyte fraction; LFR = low fluorescence ratio; MFR = medium fluorescence ratio; HFR = high fluorescence ratio; PLT-O = platelet count by optical measurement; PLT-I = platelet count by impedance measurement; NLA = not or little aggregated; HA = highly aggregated Outliers: a 24.5 10 9 /l; b 1.2 10 9 /l; c 1.8 10 9 /l; d 1.6 10 9 /l; e 1.7 10 9 /l; f 1.6 10 9 /l; g 149.5 10 9 /l ; h 1.4% *No effect of analyser and anticoagulant One missing datum

Granat et al 479 were <0.5 (results not shown) and no trend could be seen. Characteristics of the reference sample group The reference sample group (n = 81) consisted of 37 females (17 intact and 20 neutered) and 44 males (12 intact and 32 neutered). The breed distribution was as follows: 75 domestic shorthair (92.7%), two Siamese (2.5%), one Blue Russian (1.2%), one Persian (1.2%), one crossbreed Birman (1.2%) and one cross-breed Siamese (1.2%). The median age was 25 months (ranging from 6 to 116 months). There was no effect of sex on age (Student s t-test, P = 0.218), and the median ages in females and males were 28.0 and 22.5 months, respectively (Figure 1). Weight was only reported for 67 cats. The overall median weight was 4.4 kg (ranging from 1.9 to 9.5 kg), with females significantly lighter than males (MannWhitney test, P <0.001), and the medians in females and males were 3.7 and 4.9 kg, respectively. Weight was positively correlated with the age of the cats (ANOVA, P = 0.023). RIs No statistically significant difference was detected between duplicates, so the mean of each variable was used in the calculations. To facilitate subsequent use, the RIs are presented in Tables 14 for each analyser and anticoagulant. However, when no difference according to instrument and anticoagulant was observed for an analyte (highlighted with an asterisk in Tables 14), the results were pooled and the same RI indicated. When different RIs are indicated, the observed differences were statistically significant (Harris and Boyd test s, z > z* ). An effect of platelet aggregation was Figure 1 Distribution of ages and sexes of 81 cats (37 females and 44 males) sampled to establish haematological reference intervals for the Sysmex XT-2000iV (Sysmex) and ProCyte DX (IDEXX Laboratories) analysers. The horizontal bars indicate medians observed for HGB, HTE, LFR, MFR, IRF, PLT-I and PLT-O, so only NLA specimens were used to calculate the corresponding RI (see above). All values for outliers are indicated as footnotes to each table. Effect of sex, age and weight Statistically significant effects of sex were observed for the means of WBC, neutrophil, lymphocyte, monocyte, RBC-I and PLT-O counts, MCV, MCHC and RDW-CV (ANOVA, P <0.05). However, the only (malefemale) differences higher than the arbitrarily selected threshold of 2% were observed for WBC, neutrophil, monocyte and lymphocyte counts (+7%, + 65%, + 50% and 18%, respectively). The effect of age was studied only within a subset of the feline population [cats up to the age of 5 years (n = 72)] because of the very low number of older cats. Age had statistically significant effects on WBC, lymphocyte, eosinophil and monocyte counts, MCV, MCH, RDW-CV and RET c (ANOVA, P <0.05). However, on visual inspection of the regression curves, notable changes were only observed for WBC, lymphocyte and monocyte counts, and for RDW-CV, with a negative correlation. A positive correlation with age was detected for MCV and MCH (Figures 2 and 3). The effect of weight was also studied in the same subset of cats 5 years old, and showed statistically significant changes for WBC, neutrophil, monocyte, RBC-I and RBC-O counts, HGB, HTE, RDW-SD, RET c, RET %, IRF, LFR and MFR (ANOVA, P <0.05). Similarly, visual inspection of the regression curves revealed notable changes only for WBC, neutrophil and monocyte counts (which were inversely correlated with weight), and RBC-I, RBC-O, HGB and HTE (which were positively correlated with weight) (see Figure 4). Discussion This prospective study was designed according to ASVCP and IFCCCLSI guidelines for the de novo establishment of RIs, and is the first one to integrate the score of platelet aggregation into the calculation of RIs for haematological analytes in cats. 6,7 The determination of health status was based on multiple objective criteria, including a complete physical examination, a negative result in the diagnostic test for retroviral infection (FeLV and FIV), and a detailed questionnaire to eliminate any sick or subclinically ill animals. In summary, the studied population included mainly young, medicalised domestic shorthair cats, as the majority of cats were 6 months to 5 years old, but was quite representative of domestic healthy cats in France. The total number of specimens was less than the 120 specimens usually considered as a minimum for the determination of RIs. However, this is a false interpretation of the recommendations, which state only that 120 is the minimal number to determine the CI of limits by a non-parametric method. Moreover, in the latest update

480 Journal of Feline Medicine and Surgery 16(6) 20 50 WBC (10 9 /l) 15 10 MCV (fl) 45 40 5 35 Lymphocytes (10 9 /l) 0 10 8 6 4 2 MCH (pg) 30 17.5 16.5 15.5 14.5 13.5 12.5 Monocytes (10 9 /l) 0 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0 Figure 2 Regression-based reference intervals of feline white blood cell (WBC), lymphocyte and monocyte counts according to age with the Sysmex XT-2000iV (Sysmex) and the ProCyte DX (IDEXX Laboratories) analysers in EDTA and CTAD blood specimens. Reference limits (solid lines) and 90% confidence intervals (dotted lines). The outliers are the same as those listed in Tables 14 of these recommendations, it is acknowledged that RIs can be determined with a smaller number of specimens, preferably with a non-parametric method for determination of the limits. This was the case here, where most RIs were determined in the reference sample group of 81 cats or in specific subsets ( 40 specimens) when the platelet aggregation score had an effect. In consequence, RDW-CV(%) 11.5 33 31 29 27 25 23 21 19 17 Figure 3 Regression-based reference intervals of feline mean corpuscular volume (MCV) and mean corpuscular haemoglobin (MCH) according to age with the Sysmex XT-2000iV analyser (Sysmex) in EDTA and CTAD blood specimens, and feline red blood cell distribution width as a percentage (RDW-CV) with the Sysmex XT-2000iV analyser in EDTA blood specimens. Reference limits (solid lines) and 90% confidence intervals (dotted lines). The outliers are the same as those listed in Tables 14 the CIs of RIs calculated for these subpopulations are also wider. In fact, only specimens that were NLA, that is, specimens associated with the arbitrary threshold of

Granat et al 481 WBC (10 9 /l) RBC-I (10 12 /l) 20 15 10 5 0 1 2 3 4 5 6 7 8 Weight (kg) 13 12 11 10 9 8 7 6 1 2 3 4 5 6 7 8 Weight (kg) Figure 4 Regression-based reference intervals of feline white blood cell (WBC) and red blood cell by impedance measurement (RBC-I) counts according to weight with the Sysmex XT-2000iV (Sysmex) and the ProCyte DX (IDEXX Laboratories) analysers in EDTA and CTAD blood specimens. Reference limits (solid lines) and 90% confidence intervals (dotted lines). The outliers are the same as those listed in Tables 14 SPA-F <2 used in previous studies, 4,5 were used to calculate the RIs for platelet aggregation-dependent analytes. In this study, the difficulty of handling and sampling was statistically significant, but no clear trend could be highlighted. This statistically significant result was therefore considered as not clinically relevant. Also, susceptibility to platelet aggregation in cats seems to be more complex than a simple equation of stress and/or tube-filling. However, this scoring was subjective and could be improved by using objective criteria such as clinical and biological assessments of stress. 15 The two analysers used in this study have very similar technology (a mix of optical and impedance technology). However, some statistical differences were observed between the RIs obtained with the Sysmex XT-2000iV and the ProCyte DX analysers used in this study. The main differences concerned the MCV values, which were lower with the Sysmex XT-2000iV than with the ProCyte DX, and the RET c values, which were higher with the Sysmex XT-2000iV than with the ProCyte DX. Other, more moderate, differences were observed for MCH, MCHC, HGB and RET % values, which were higher with the Sysmex XT-2000iV than with the ProCyte DX, and for the HTE values, which were lower with the Sysmex XT-2000iV than with the ProCyte DX. The RIs obtained in different studies are difficult to compare because of the different characteristics of the reference sample groups, and possible differences in preanalytical conditions and analytical performances of the instruments. Nevertheless, we have chosen to compare the RIs obtained in our study with the Sysmex XT-2000iV analyser to the RIs obtained with the ADVIA 120 (data given in Table 3) the analyser based on the most comparable technology and the closest reference population (by geographical location) to our analyser and study design, respectively. 1 All the differences concerning the leukocyte and erythrocyte populations could result from: (1) the number of cats included in the calculation of the RIs; (2) the selected reference sample group; and (3) the different technology, manufacturer s calibration and software version. The lower limit of platelet count obtained with the Sysmex XT-2000iV is somewhat higher than with the ADVIA 120, whereas the upper limits are very similar, and this is probably owing to the more stringent procedure of eliminating specimens with platelet clumps adopted in this study. The RIs obtained in CTAD cannot be compared with previous results, as this anticoagulant is not yet frequently used. The most obvious differences between the RIs obtained in EDTA and CTAD specimens were quite similar for the ProCyte DX and the Sysmex XT-2000iV analysers, and were especially observed for platelet count, with (1) a high percentage of EDTA specimens showing platelet aggregation (these specimens being excluded from the calculations of the RIs); and (2) a lower reference limit with a wider 90% CI in NLA EDTA specimens than in CTAD specimens. These differences could be explained by the fact that (1) some platelet clumps could be present in this subset (particularly for specimens with 1 <SPA-F <2, which still exhibited some aggregation, that is, 15/40 in the EDTA group vs only 5/80 in the CTAD group); and (2) the RI in EDTA specimens was calculated on a subpopulation of cats that only included NLA specimens and was smaller (n = 40) than the same subpopulation of NLA CTAD specimens (n = 80). No breed effect could be investigated as very few purebred cats were included in this study (4/81). The effect of sex was only significant for the WBC, neutrophil, monocyte and lymphocyte counts in our study. Moderate sex differences have been previously observed, with males having a higher HGB concentration and RBC count; there is some controversy regarding WBC counts. 16 The clearest difference reported in the literature is for the HGB concentration,

482 Journal of Feline Medicine and Surgery 16(6) but our results did not confirm this observation. 16 For the effect of age, this study showed a decrease of WBC, lymphocyte and monocyte counts, and RDW-CV, and an increase of MCV and MCH with age within a population composed solely of cats younger than 5 years of age. To our knowledge, very few studies have been performed on the effect of age on haematology in cats older than 1 year, but the similar variations of WBC and lymphocyte counts with age were also observed in a previous study performed on canine specimens. 17 This latter study also showed a decrease in neutrophil count with age in canine specimens, whereas our study did not reveal any variation of neutrophil count, but a decrease in monocyte count with age in feline specimens. Even if a tendency can be observed in our study, a new investigation needs to be carried out on older healthy cats to provide valuable information about the consequences of age on CBC variables. The effect of weight has not been mentioned before. We observed a relevant effect of weight on WBC, neutrophil, monocyte counts, RBC-I, and RBC-O counts, HGB and HTE. However, as weight was positively correlated with age in our study, it is not possible to confirm the sole effect of weight, and these observations require further investigation. Conclusions This is the first study to establish haematological RIs of feline blood specimens collected in CTAD and EDTA for two laser-based analysers, the Sysmex XT-2000iV and the ProCyte DX. Both analysers give very similar results, except for MCV and RET c, which could result, at least in part, from manufacturer calibration and the software version used. The RIs in CTAD are almost the same as in EDTA, except for PLT count, thus confirming the interest of using this anticoagulant for feline blood samples. These RIs can be directly applied in veterinary laboratories or clinics where these analysers and anticoagulants are used in a similar population of cats. Breed effect could not be investigated in this study, but may exist, as reported for some biochemical analytes. 18 Moreover, this study underlines the importance for a laboratory to establish RIs either de novo or by transfer method when a new instrument is introduced in the laboratory. Funding This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors. Conflict of interest The Sysmex XT-2000iV analyser and the ProCyte DX analyser used in this study were made available as a free loan by the manufacturers, which were not involved in any step or funding of this study. References 1 Moritz A, Fickenscher Y, Meyer K, et al. Canine and feline hematology reference values for the ADVIA 120 hematology system. Vet Clin Pathol 2004; 33: 3238. 2 Reynolds BS, Boudet KG, Faucher MR, et al. Comparison of a new device for blood sampling in cats with a vacuum tube collection system plasma biochemistry, haematology and practical usage assessment. J Feline Med Surg 2007; 9: 382386. 3 Norman EJ, Barron RC, Nash AS and Clampitt RB. Evaluation of a citrate-based anticoagulant with platelet inhibitory activity for feline blood cell counts. Vet Clin Pathol 2001; 30: 124132. 4 Granat F, Geffré A, Braun JP and Trumel C. Comparison of platelet clumping and complete blood count results with Sysmex XT-2000iV in feline blood sampled in EDTA or EDTA plus CTAD. J Feline Med Surg 2011; 13: 953958. 5 Granat F, Geffré A, Bourgès-Abella N, et al. Changes in haematology measurements with the Sysmex XT-2000iV during storage of feline blood sampled in EDTA or EDTA plus CTAD. J Feline Med Surg 2013; 15: 433444. 6 Friedrichs KR, Harr KE, Freeman KP, et al. ASVCP reference interval guidelines: determination of de novo reference intervals in veterinary species and other related topics. Vet Clin Pathol 2012; 41: 441453. 7 Clinical and Laboratory Standards Institute (CSLI). Defining, establishing, and verifying reference intervals in the clinical laboratory; approved guideline, document C28- A3. 3rd ed. Wayne: CLSI, 2008. 8 Lilliehook I and Tvedten H. Validation of the Sysmex XT- 2000iV hematology system for dogs, cats and horses. II. Differential leukocyte counts. Vet Clin Pathol 2009; 38: 175182. 9 Lilliehöök I and Tvedten HW. Errors in basophil enumeration with 3 veterinary hematology systems and observations on occurrence of basophils in dogs. Vet Clin Pathol 2011; 40: 450458. 10 Virtanen A, Kairisto V, Irjala K, et al. Regression-based reference limits and their reliability: example on hemoglobin during the first year of life. Clin Chem 1998; 44: 327335. 11 Virtanen A, Kairisto V, Irjala K, et al. Regression-based reference limits: determination of sufficient sample size. Clin Chem 1998; 44: 23532358. 12 Geffré A, Friedrichs K, Harr K, et al. Reference values: a review. Vet Clin Pathol 2009; 38: 288298. 13 Geffré A, Concordet D, Braun JP and Trumel C. Reference Value Advisor: a new freeware set of macroinstructions to calculate reference intervals with Microsoft Excel. Vet Clin Pathol 2011; 40: 107112. 14 Anon. Reference Value Advisor macroinstructions. http://www.biostat.envt.fr/spip/spip.php?article63 (2009, accessed September 2012). 15 Rand JS, Kinnaird E, Baglioni A, et al. Acute stress hyperglycemia in cats is associated with struggling and increased concentrations of lactate and norepinephrine. J Vet Intern Med 2002; 16: 123132. 16 Schalm OW. Normal values in blood morphology. In: Schalm OW (ed). Veterinary hematology. Philadelphia: Lea & Febiger, 1961, pp 143150. 17 Bourgès-Abella N, Geffré A, Concordet D, et al. Canine hematology reference intervals for the XT-2000iV analyzer. Vet Clin Pathol 2011; 40: 303315. 18 Reynolds BS, Concordet D, Germain CA, et al. Breed dependency of reference intervals for plasma biochemical values in cats. J Vet Intern Med 2010; 24: 809818.