Validation of assay indicating method development of meloxicam in bulk and some of its tablet dosage forms by RP-HPLC

Similar documents
Asian Journal of Pharmaceutical Research and Development (An International Peer-Reviewed Journal of Pharmaceutical Research and Development)

SPECTROPHOTOMETRIC ESTIMATION OF MELOXICAM IN BULK AND ITS PHARMACEUTICAL FORMULATIONS

Scholars Research Library

Isocratic Reverse Phase High Performance Liquid Chromatographic Estimation of Ramipril and Amlodipine in Pharmaceutical Dosage Form

Development and validation of a HPLC analytical assay method for amlodipine besylate tablets: A Potent Ca +2 channel blocker

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF ALISKIREN AND AMLODIPINE IN TABLET DOSAGE FORM

Development and Validation of UV Spectrophotometric Area Under Curve (AUC) method for estimation of Pyrantel Pamoate in Bulk and Tablet Dosage Form

Determination of ofloxacin in bulk drug and pharmaceutical dosage form by high performance liquid chromatography method

Deptt of Pharma Science SGRR ITS Patel Nagar, Dehradun (UK)

VALIDATED RP-HPLC METHOD FOR THE SIMULTANEOUS DETERMINATION OF AMLODIPINE BESYLATE AND ATORVASTATIN CALCIUM IN BULK AND PHARMACEUTICAL FORMULATION

Pharma Research Library. 2013, Vol. 1(1):19-29

Journal of Global Trends in Pharmaceutical Sciences

SIMPLE U.V. SPECTROPHOTOMETRIC METHODS FOR THE ESTIMATION OF OFLOXACIN IN PHARMACEUTICAL FORMULATIONS

International Journal of Pharmaceutical Research & Analysis

ABSTRACT. Usharani N, Divya K and Ashrtiha VVS. Original Article

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF AMLODIPINE BESYLATE AND IRBESARTAN

DEVELOPMENT OF A REVERSED PHASE - HPLC METHOD FOR DETERMINATION OF MELOXICAM IN TABLET FORMULATION AND HUMAN SERUM

METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF OFLOXACIN AND ORNIDAZOLE IN TABLET DOSAGE FORM BY RP-HPLC

Development and Validation of RP-HPLC Method for Determination of Related Substances of Medetomidine in Bulk Drug

Kamepalli Sujana et al. / Journal of Pharmacy Research 2014,8(12), Available online through

AMOXICILLIN AND CLAVULANIC ACID TABLETS Draft proposal for The International Pharmacopoeia (February 2018)

Novel RP-HPLC Method Development and Validation of Meloxicam Suppository

PO. Vasan, Gandhinagar District, Gujarat, India, 3 Dean at Faculty of Pharmacy, Dharmsinh Desai University, Nadiad, Gujarat, India.

Development and Validation of a UV- Spectrophotometric Method for Determination of Meloxicam in Bulk and in TabletFormulations

C 22 H 28 FNa 2 O 8 Pıı516.4

Compliance. Should you have any questions, please contact Praveen Pabba, Ph.D., ( or

Available online International Journal of Pharmaceutical Research & Allied Sciences, 2016, 5(4):37-44.

DETERMINATION OF ACTIVE SUBSTANCES IN MULTICOMPONENT VETERINARY PREPARATIONS OF ANTIPARASITIC ACTION BY HPLC METHOD

HPLC method for simultaneous determination of Albendazole metabolites in plasma

Development and validation of HPLC method for simultaneous estimation of Amlodipine besylate and Enalapril maleate in solid dosage form

European Journal of Biomedical and Pharmaceutical ISSN Sciences

Method development and validation for simultaneous estimation of telmisartan and amlodipine by RP-HPLC

Tamboli Ashpak Mubarak et al. IRJP 2 (8)

Should you have any questions, please contact Edith Chang, Ph.D., Senior Scientific Liaison ( or

Development and Validation of Amlodipine Impurities in Amlodipine Tablets Using Design Space Computer Modeling

Ultra-Fast Analysis of Contaminant Residue from Propolis by LC/MS/MS Using SPE

Determination of Amlodipine in Rat Plasma by UV Spectroscopy

Development And Validation Of Methods For Estimation Of Pimobendan In Pharmaceutical Dosage Form

Specific and Simple HPLC Assay of Ecofriendly Meloxicam in Pharmaceutical Formulations K.T. Mahmood 1, B.Khan 2, M. Ashraf 3 and I. U.

Streptomycin Sulfate According to USP

Original Article. Abstract INTRODUCTION

Pradhan Prasanna Kumar et al. Int. Res. J. Pharm. 2014, 5 (9) INTERNATIONAL RESEARCH JOURNAL OF PHARMACY

Amlodipine, Valsartan, and Hydrochlorothiazide Tablets

A NOVEL STABILITY INDICATING RP-HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF MOXIFLOXACIN AND PREDNISOLONE IN BULK AND THEIR COMBINED DOSAGE FORM

Sensitive and selective analysis of fipronil residues in eggs using Thermo Scientific GC-MS/MS triple quadrupole technology

Determination of Benzimidazole Residues in Animal Tissue by Ultra High Performance Liquid Chromatography Tandem Mass Spectrometry

RP-HPLC Method for Simultaneous Estimation of Enalapril Maleate and Chlorthalidone in Synthetic Mixture

INTERNATIONAL RESEARCH JOURNAL OF PHARMACY

Stability indicating HPLC method for the simultaneous determination of moxifloxacin and prednisolone in pharmaceutical formulations

A Simple Sample Preparation with HPLC UV Method for Estimation of Amlodipine from Plasma: Application to Bioequivalence Study

Quantification of Chloramphenicol in Chicken Using Xevo TQD with RADAR Technology

Development and Validation of a RP-HPLC Method for Simultaneous Determination of Levofloxacin and Moxifloxacin in Pharmaceutical Dosage Forms

Journal of Applied Pharmaceutical Research ISSN No

Rapid LC-MS/MS Method for the Analysis of Fipronil and Amitraz Insecticides and Associated Metabolites in Egg and Other Poultry Products

A VALIDATED HPLC-ASSAY FOR THE DETERMINATION OF MELOXICAM IN PRESENCE OF ITS DEGRADATION PRODUCTS

A Validated RP-HPLC Method for Simultaneous Estimation of Nebivolol Hydrochloride and S-Amlodipine Besylate in Tablet Dosage Forms

Chandra Mohan Rao Kota et al INTERNATIONAL JOURNAL OF RESEARCH AND REVIEWS IN PHARMACY AND APPLIED SCIENCES

Spectrophotometric Method for Simultaneous Estimation of Amlodipine Besylate in Pharmaceutical Formulation

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

Determination, Confirmation and Quantitation of Multi-Class Antibiotic Residues in Milk by UHPLC MS/MS

STABILITY INDICATING RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF MOXIFLOXACIN

Sci Pharm

Determination of Acaricides in Korean Honey Bull. Korean Chem. Soc. 2008, Vol. 29, No

Research Article Difference Spectroscopic Method for the Estimation of Amlodipine Besylate in Bulk and in Formulation

Quantification of Albendazole in Dewormer Formulations in the Kenyan market

TLC DETERMINATION OF MELOXICAM IN TABLETS AND AFTER ACIDIC AND ALKALINE HYDROLYSIS

Keywords: Derivative spectrophotometry, Telmisartan, Hydrochlorthiazide, Amlodipine ABSTRACT

A reverse phase high performance liquid chromatography method was developed for simultaneous estimation of

Development and method validation on stress degradation studies of cefpodoxime proxetil and clavulanic acid in dosage form by hplc method

Simultaneous UV-spectrophotometric estimation of ibuprofen and moxifloxacin in ph 6.8 phosphate buffer

A Path for Horizing Your Innovative Work

New Stability Indicating Method for Quantification of Impurities in Amlodipine and Benazepril Capsules by Validated HPLC

Development and validation of RP HPLC method for the estimation of Tylosin tartrate in pure and pharmaceutical formulation

formulations, in dissolution studies. The method is rapid, simple, accurate, and precise without the need of high-cost investment.

MOXIFLOXACIN HYDROCHLORIDE (MOXIFLOXACINI HYDROCHLORIDUM) Draft proposal for The International Pharmacopoeia. (January 2018)

Development and Validation of TLC-Densitometry Method for Simultaneous Determination of Telmisartan and Amlodipine Besylate in Bulk and Tablets

Stability indicating HPLC Method Validation for the Assay of Dexmedetomidine in Dexmedetomidine Hydrochloride Injection

DEVELOPMENT AND VALIDATION OF HPLC/UV METHOD FOR DETERMINATION OF MELOXICAM IN HUMAN PLASMA AND APPLICATION IN PHARMACOKINETIC STUDIES

Analysis of Multiclass Veterinary Drugs in Baby Food by Ultra Fast Chromatography with High Performance Triple Quadrupole Mass Spectrometry

Detection of residues of quinolones in milk

Veterinary Drug Detection in Pork and Milk

Multi-residue Method II for Veterinary Drugs by HPLC (Animal and Fishery Products)

Simultaneous Estimation of Nebivolol hydrochloride and Amlodipine besylate by UV Spectrophotometric Method

Application of hydrotropic solubilization technique for simultaneous estimation and validation of ofloxacin and ornidazole in tablet dosage form

Fig.1: Structure of Desloratadine

International Journal of Pharmacy and Pharmaceutical Sciences. Research Article

Stability Indicating Spectrophotometric Method of Amlodipine and Telmisartan in Bulk and Pharmaceutical Dosage Form

UV-absorbance difference method for simultaneous estimation of atenolol and amlodipine besylate in combined dosage forms

Int. J. Pharm. Sci. Rev. Res., 34(2), September October 2015; Article No. 10, Pages: 61-67

SIMPLE HPLC METHOD FOR THE DETERMINATION OF CEFIXIME, OFLOXACIN AND LINEZOLID IN SOLID DOSAGE FORMS

[ APPLICATION NOTE ] Analysis of Ketamine and Xylazine in Rat Tissues Using the ACQUITY UPLC with 2D Technology APPLICATION BENEFITS INTRODUCTION

Received 29 January, 2010; received in revised form 15 March, 2010; accepted 25 March, 2010

Shivaprakash a,*, H. Saroj a, K.M. Bhat b

RAPID RP-HPLC METHOD WITH PDA DETECTION FOR TYLOSIN DETERMINATION IN LIQUID SAMPLES

A Unique Approach to Managing the Problem of Antibiotic Resistance

Quantification of Several Acidic Drugs in Equine Serum Using LC MS-MS

ANALYTICAL METHOD VALIDATION FOR DETERMINATION OF RELATED SUBSTANCES OF DEXMEDETOMIDINE (IMPURITY-1) IN DEXMEDETOMIDINE HYDROCHLORIDE INJECTION

Determination of Beta-Lactamase Inactivation of Cephalexin by Validated RP-HPLC Method

A simple and easy method for determination of meloxicam in rat muscle and plasma

DEVELOPMENT AND VALIDATION OF AMOXICILLIN AND CLAVULANATE BY USING LC-MS METHOD

Transcription:

Sahoo et al. SpringerPlus 2014, 3:95 a SpringerOpen Journal RESEARCH Validation of assay indicating method development of meloxicam in bulk and some of its tablet dosage forms by RP-HPLC Nalini Kanta Sahoo 1*, Madhusmita Sahu 1, Podilapu Srinivasa Rao 1, N Sandhya Rani 1, JNV Indira Devi 1 and Goutam Ghosh 2 Open Access Abstract A novel, simple and economic reverse phase high performance liquid chromatography (RP-HPLC) method has been developed for the quantification of Meloxicam in bulk and tablet dosage form with greater precision and accuracy. Separation was achieved on Develosil ODS HG-5 RP C 18,(15cm 4.6mmi.d.5μm) column in isocratic mode with mobile phase consisting of acetonitrile: phosphate buffer(ph 3.4) (60:40) with a flow rate of 1 ml/min. The detection was carried out at 268 nm. The retention time of Meloxicam was found to be 2.09 min. The method was validated as per ICH guidelines. Linearity was established for Meloxicam in the range 20 120 μg/ml with R 2 value 0.996. The percentage recovery of Meloxicam was found to be in the range 99.99-100.46%. The high recovery and low relative standard deviation confirm the suitability of the proposed method for the estimation of the drug in bulk and tablet dosage forms. Validation studies demonstrated that the proposed RP-HPLC method is simple, specific, rapid, reliable and reproducible for the determination of Meloxicam for Quality Control level. Keywords: RP-HPLC; Meloxicam; Quality control level Introduction Meloxicam (MEL), shown in Figure 1, is chemically, 4-hydroxy-2-methyl-N-(5-methyl-2-thiazolyl)-2H,1,2- benzothaizine-3-carboxamide-1, 1-dioxide. It is used for the treatment of osteoarthritis, rheumatoid arthritis, and pauciarticular and polyarticular course juvenile rheumatoid arthritis. Its analgesic, antipyretic and antiinflammatory activity is due to the inhibition of COX-2 enzyme (Noble & Balfour 1996; Davies & Skjodt 1999). Meloxicam pharmacological activity is greatly affected by the substituents on parent oxicam moiety e.g. change in methyl to ethyl at 2 positions causes complete suppression of activity (Lemke & Williams 2008). Several analytical methods for the determination of meloxicam by flourimetry (Hassan 2002), capillary electrophoresis (Nemutlu & Kir 2003), spectrophotometry (Hassan 2002), HPLC (Arayne et al. 2005; Farzana & Pradeep 2009; * Correspondence: sahoo.nalini@gmail.com 1 Yalamarty Pharmacy College, Tarluwada, Visakhapatnam 530052, AP, India Full list of author information is available at the end of the article Damle et al. 2009), LC/MS (Wiesner et al. 2003) and polarographic (Altıokka et al. 2000; Radi et al. 2001a; Altınöz et al. 2002; Radi et al. 2001b; Rao et al. 2005) have been reported. The aim of the present work was to develop and validate a sensitive RP-HPLC method that can be implemented for the quantification of meloxicam in bulk as well as in its tablet dosage forms. Experimental Materials Pure Meloxicam (MEL) used as working standards, was purchased from Yarrow chem. Products, Mumbai, India. Tablets containing 15 mg and 7.5 mg of meloxicam (MUVERA15 and MOVAC) were obtained from Apollo Pharmaceuticals Pvt. Ltd, Visakhapatnam, India and used within their shelf life period. Acetonitrile and water (HPLC-grade) were purchased from Merck, India. All other chemicals and reagents employed were of analytical grade, and purchased from Merck, India. 2014 Sahoo et al.; licensee Springer. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.

Sahoo et al. SpringerPlus 2014, 3:95 Page 2 of 6 Figure 1 Chemical structure of Meloxicam. Instrumentation The chromatographic system used comprised of Analytical technologies ltd UV 2230 UV vis detector. Data integration was carried out using A-4000 version software. Samples were injected into Develosil ODS HG- 5RPC 18 (5 μm, 15 cm 4.6 mm i.d) column. An Analytical technologies ltd.sonicator was used for enhancing the dissolution of the compounds. A Wenster digital ph meter was used for ph adjustment. Preparation of standard solutions The stock solution was prepared by transferring 100 mg of Meloxicam into 100 ml volumetric flask. Then it was added with small amount of diluent [acetonitrile: water (50:50)], and the mixture was sonicated to dissolve and made up to volume with mobile phase. From this stock solution different concentrations were prepared to give final concentrations of 20 120 μg/ml for standard calibration curve. Chromatographic conditions The high performance liquid chromatographic (HPLC) system used was operated isocratically with the column temperature maintained at 30 C, using a mobile phase composition of acetonitrile and phosphate buffer (ph adjusted to 3.4 with O-Phosphoric acid) in the ratio of 60:40 v/v at a flow rate of 1.0 ml/min within a run time of 7 min. Prior to use, the mobile phase was degassed by an ultrasonic bath and filtered by a Millipore vacuum filter system equipped with a 0.45 μm high vacuum filter. The drug was detected and quantified at 268 nm. Assay of meloxicam from marketed tablets Twenty tablets were accurately weighed and crushed to a fine powder in a mortar in each of the marketed formulation separately. An amount of the powder equivalent to 100 mg was transferred into a 100 ml volumetric flask and 10 ml of diluent was added to it followed by 10 ml of 0.1 N NaOH. The mixture was sonicated to dissolve the exipients and then made up to volume with mobile phase. Following 15 min of mechanical shaking, it was kept in an ultrasonic bath for 15 mins, and the solution was filtered through a 0.45 μm filter paper. Suitable aliquots (1 ml each) of the filtered solution were Table 1 Results of optimization Column used Mobile phase Flow rate Wave length Observation Result Microbondapak C 18,5μm, Methanol only 0.5 ml/min 254 nm Low resolution below 1. Method rejected 50 4.6 mm i.d. Phenomenex RP- C 18, Luna 5 μm, 250 4.6 mm i.d. Microbondapak C 18,5μm, 50 4.6 mm i.d. Phenomenex RP- C 18, Luna 5 μm, 250 4.6 mm i.d. Develosil ODS HG-5 RP C 18,5μm, 15cm 4.6 mm i.d. Acetonitrile only 0.8 ml/min 358 nm Resolution i.e. 1.2 but not satisfied Acetonitrile: phosphate buffer(ph7.8) = 70:30 Acetronitrile: phosphate buffer(ph 5.0 = 60:40 Acetonitrile: phosphate buffer(ph 3.4) (60:40) Method rejected 1 ml/min 270 nm Poor resolution i.e. 1.5 Method rejected 1 ml/min 270 nm Poor resolution i.e. 1.2 Method rejected 1 ml/min 268 nm Sharp peak and good resolution i.e. 2.3 Method accepted

Sahoo et al. SpringerPlus 2014, 3:95 Page 3 of 6 Table 2 Results of linearity and range Sl. no Conc. Area 1 20 1000024 2 40 1698687 3 60 2502000 4 80 3213014 5 100 3824253 6 120 4605216 linearity, accuracy, and limit of detection (LOD), limit of quantification (LOQ), precision, reproducibility, robustness and system suitability. Figure 2 RP-HPLC Chromatogram of Meloxicam standard drug. transferred to 50 ml volumetric flasks and made up to volume with mobile phase to yield six concentrations of Meloxicam (20 μg/ml). A 20 μl volume of the sample solution was injected into the chromatographic system, six times, under optimized chromatographic conditions. The peak areas were measured at 268 nm and concentrations in the samples were determined by interpolation from standard calibration curve of each drug previously obtained. Method validation The method was validated in accordance with ICH guidelines (International Conference on Harmonization (ICH) of Technical Requirements for Registration of Pharmaceuticals for Human Use 2010). The parameters assessed were Accuracy Accuracy was best determined by the standard addition method. Previously analyzed samples of Meloxicam API were added with standard drug solutions and are analyzed by the proposed method. Recovery (%), RSD (%) and bias (%) were calculated for each concentration. Accuracy is reported as percentage bias, which is calculated from the expression measured value true value % Bias ¼ ð Þ 100 true value Precision Precision was determined as both repeatability and intermediate precision, in accordance with ICH guidelines. Repeatability of sample injection was determined as intraday variation and intermediate variation. For these determinations, single concentration (20 μg/ml)atdifferent time intervals and different days, of the solution of Meloxicam API was used. 5000000 4500000 4000000 3500000 3000000 2500000 2000000 1500000 1000000 500000 0 0 50 100 150 Figure 3 Calibration curve for Meloxicam. y = 37461x + 158481 R² = 0.9964 Series1 Linear (Series1)

Sahoo et al. SpringerPlus 2014, 3:95 Page 4 of 6 Table 3 Results of recovery study Amount of drug added (μg) to analyte Robustness The concept of robustness of an analytical procedure has been defined by the ICH as a measure of its capacity to remain unaffected by small but deliberate variations in method parameters. To determine the robustness of the method experimental conditions are purposely altered and chromatographic characters are evaluated. Influence of small changes in chromatographic conditions such as change in flow rate (± 0.1 ml/min), wavelength of detection (±2 nm) and acetonitrile content in mobile phase (±2%) were studied to determine the robustness of the method. Limit of detection (LOD) The limit of detection (LOD) of an analytical method may be defined as the concentration, which gives rise to an instrument signal that is significantly different from the blank. For spectroscopic techniques or other methods that rely upon a calibration curve for quantitative measurements, the IUPAC approach employs the standard deviation of the intercept (Sa), which may be related to LOD and the slope of the calibration curve, b, by LOD ¼ 3Sa=b Mean amount (μg ) found (n = 6) Recovery from formulation Mean % recovery % RSD % Bias 32 32.148 100.46 1.662 0.462 40 40.021 100.05 1.502 0.052 48 47.954 99.99 0.2757 0.095 Limit of quantitation (LOQ) The LOQ is the concentration that can be quantitated reliably with a specified level of accuracy and precision. The LOQ represent the concentration of analyte that would yield a signal-to-noise ratio of 10. Table 5 Results of robustness test Change in parameter % RSD (n = 6) Flow (0.9 ml/min) 0.14 Flow (1.1 ml/min) 0.02 Wavelength of Detection (270 nm) 0.09 Wavelength of detection (266 nm) 0.61 Acetonitrile: Phosphate buffer (62:38) 0.14 Acetonitrile: Phosphate buffer (58:42) 0.19 LOQ ¼ 10 Sa=b Where, Sa is the standard deviation of the peak area ratio of analyte to IS (6 injections) of the drugs and b is slope of the corresponding calibration curve. Results and discussion Optimization of chromatographic conditions The chromatographic conditions were optimized by different means i.e. using different column, different mobile phase, different flow rate, different detection wavelength and different diluents for standard drug and marketed tablets are summarized in Table 1 and different chromatograms (Figure 2) are shown. Linearity & range The standard calibration curve(figure 3) showed good linearity in the range of 20 120 μg/ml (Table 2), for Meloxicam API with correlation coefficient (r 2 ) of 0.996. A typical calibration curve has the regression equation of y = 37461x + 158481 for Meloxicam. Accuracy: recovery study The recovery of the method, determined by adding a previously analyzed test solution with additional drug standard solution at three levels of concentration, was 99.99-100.46%. The values of recovery (%), RSD (%) and % Bias listed in Table 3 indicate the method is accurate. Precision: Intra-assay & inter-assay The intra & inter day variation of the method was carried out and the high values of mean assay and low Table 4 Results of intra-assay & inter-assay Conc. of Meloxicam Observed conc. of Meloxicam (μg/ml) by the proposed method (20 μg/ml) Intra-Day Inter-Day Mean (n = 6) % RSD Mean (n = 6) % RSD 9 A.M 22.463 0.01 Day 1 21.89 0.08 1 P.M 22.463 0.01 Day 2 21.93 0.04 5 P.M 22.463 0.01 Day 3 20.99 0.01

Sahoo et al. SpringerPlus 2014, 3:95 Page 5 of 6 Table 6 Assay of meloxicam tablets S. No Formulations Standard peak area Sample peak area Labeled amount (mg) Amount found (mg) % Assay ± RSD 1 Muvera 15 1000024 1000011 15 14.99 99.99 ± 0.12 2 Movac 1000024 1000191 7.5 7.5 100.01 ± 0.02 values of standard deviation and % RSD (% RSD < 2%) within a day and day to day variations for Meloxicam revealed that the proposed method is precise (Table 4). Robustness Influence of small changes in chromatographic conditions such as change in flow rate (± 0.1 ml/min), Wavelength of detection (±2 nm) & acetonitrile content in mobile phase (±2%) studied to determine the robustness of the method are also in favor of (Table 5, % RSD < 2%) the developed RP-HPLC method for the analysis of Meloxicam API. LOD & LOQ The Minimum concentration level at which the analyte can be reliable detected (LOD) & quantified (LOQ) were found to be 0.42 & 1.29 μg/ml respectively. Assay of meloxicam in tablet dosage forms Assay was performed by using the regression equation (y = 37461x + 158481, R 2 = 0.996) obtained from the standard calibration curve of Meloxicam API. Results obtained are given in Table 6. The assay of Muvera 15 and Movac tablet containing Meloxicam was found to be 99.99 and 100.01% respectively as per the method. The chromatograms are represented in Figures 4 and 5. The method is having linearity in the range 20 to 120 μg/ml with regression coefficient value 0.99. When compared to previous methods for recovery study, the % recovery is nearly 100%. Precision results are having low % RSD value i.e. below 0.1 in comparison to previous methods, which is an added advantage. Similarly in previous methods assay in marketed formulation is carried out by considering single formulation, but the present method uses two different formulations. Also at very low concentration it can be detected and quantified i.e. at 0.42 & 1.29 μg/ml, which is not observed in previous methods. For these reasons the method is proved to be novel in comparision to existed methods. Conclusion A New RP-HPLC method indicating assay of MEL in bulk and in pharmaceutical dosage forms is established. This method is simple, reliable, linear, accurate, sensitive and reproducible as well as cost effective for the effective quantitative analysis of MEL in bulk and tablet formulations. The method was completely validated showing satisfactory data for all the method validation parameters tested and method is free from interference of the other active ingredients and additives used in the formulations. Therefore the method is suitable for use of the routine quality control analysis of Meloxicam in API or in pharmaceutical dosage forms. Figure 4 RP-HPLC Chromatogram of Muvera 15 Tablet. Figure 5 RP-HPLC Chromatogram of Movac Tablet.

Sahoo et al. SpringerPlus 2014, 3:95 Page 6 of 6 Competing interests The authors declare that they have no competing interests. Authors contributions NK has designed the entire procedure and done the entire work. M has done method optimisation. PS and G has done some validation parameters. JN and N have done rest of validations. All the authors have read the article and approved the final manuscript. Acknowledgements The authors would like to acknowledge the contributions of Yalamarty Pharmacy College, Tarluwada, Anandapuram, Visakhapatnam, Andhra Pradesh, India for providing necessary facilities to carry out the research work. Author details 1 Yalamarty Pharmacy College, Tarluwada, Visakhapatnam 530052, AP, India. 2 School of Pharmaceutical Sciences, SOA University, Kalinganagar, 751003 Orissa, BBSR, India. Received: 12 November 2013 Accepted: 10 February 2014 Published: 18 February 2014 References Altınöz S, Nemutlu E, Kır S (2002) Polarographic behaviour of meloxicam and its determination in tablet preparations and spiked plasma. Farmaco 57:463 468 Altıokka G, Atkosar Z, Tuncel M (2000) Pulse polarographic determination of meloxicam. Pharmazie 56:184 185 Arayne MS, Sultana N, Siddiqui FA (2005) A new RP-HPLC method for analysis of meloxicam in tablets. Pak J Pharm Sci 18:58 62 Damle MC, Sinha PK, Jeswani RM, Topagi KS (2009) A validated RP-HPLC method for determination of Meloxicam in the Presence of its Impurities. Int J Pharm Tech Res 1:1051 1060 Davies NM, Skjodt NM (1999) Clinical pharmacokinetics of meloxicam. Clin Pharmacokinet 36:115 122 Farzana SB, Pradeep RV (2009) A stability indicating HPLC method for the determination of meloxicam in bulk and commercial formulations. Trop J Pharm Res 8:257 264 Hassan EM (2002) Spectrophotometric and fluorimetric methods for the determination of meloxicam in dosage forms. J Pharm Biomed Anal 27:771 793 International Conference on Harmonization (ICH) of Technical Requirements for Registration of Pharmaceuticals for Human Use (2010) Harmonized Triplicate Guideline on Validation of Analytical Procedures: Methodology, Recommended for Adoption at Step 4 of the ICH Process on November 1996 by the ICH Steering Committee. IFPMA, Switzerland Lemke LT, Williams AD (2008) Foye s Principles of Medicinal Chemistry. W. Lippincot and wilkin, New York Nemutlu E, Kir S (2003) Method development and validation for the analysis of meloxicam in tablets by CZE. J Pharm Biomed Anal 31:393 405 Noble S, Balfour JA (1996) Meloxicam. Drugs 51:424 431 Radi A, El-Ries MA, El-Anwar F, El-Sherif Z (2001a) Electrochemical oxidation of meloxicam and its determination in tablet dosage form. Anal Lett 34:739 748 Radi AE, Ghoneim M, Beltagi A (2001b) Cathodic adsorptive stripping square-wave voltammetry of the anti-inflammatory drug meloxicam. Chem Pharm Bull 49:1257 1260 Rao RN, Meena S, Rao AR (2005) An overview of the recent developments in analytical methodologies for determination of COX-2 inhibitors in bulk drugs, pharmaceuticals and biological matrices. J Pharm Biomed Anal 39:349 367 Wiesner JL, De Jager AD, Sutherland FCW, Hundt HKL, Swart KJ, Hundt AF, Els J (2003) Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of meloxicam in human plasma. J Chromatogr B 785:115 121 doi:10.1186/2193-1801-3-95 Cite this article as: Sahoo et al.: Validation of assay indicating method development of meloxicam in bulk and some of its tablet dosage forms by RP-HPLC. SpringerPlus 2014 3:95. Submit your manuscript to a journal and benefit from: 7 Convenient online submission 7 Rigorous peer review 7 Immediate publication on acceptance 7 Open access: articles freely available online 7 High visibility within the field 7 Retaining the copyright to your article Submit your next manuscript at 7 springeropen.com