Pet-Temp PT-300 Ear Thermometer Frequently Asked Questions

Similar documents
7300 SPT 7302 SPT 7800 SPT 7802 D.T. SYSTEMS, INC.

OPERATING AND BASIC TRAINING GUIDE PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING

INNOTEK. Spray Bark Control. Operating Guide. Please read this entire guide before beginning.

NoBark 6. Operating Guide. Please read this entire guide before beginning

Outdoor Bark Control

INTRODUCTION PRODUCT FEATURES. Congratulations on your purchase of the Yapper Stopper Model YS500.

Operating Guide. PBC Rechargeable Bark Control Collar. Please read this entire guide before beginning.

Elite Outdoor Bark Control

Ultra Min No-Bark Training Collar Ultra Small Ultra Powerful Ultra Control

Smart bark control collar BC-2. User manual

SportHunter SD Operating Guide. Please read this entire guide before beginning

Basic Bark Control Collar

MGL Avionics EFIS G2 and iefis. Guide to using the MGL RDAC CAN interface with the UL Power engines

COOPER POWER SERIES. S.T.A.R. Type ER faulted circuit indicator installation instructions. Fault Indicators MN320006EN

PetSpy Premium Dog Training Collar, Models M919-1/M919-2

What is the average time needed to train a dog using a pet containment system?

By Dogtra Remote Controlled Dog Training Collars. Owner's Manual. Please read this manual thoroughly before operating the Dogtra ARC training collar.

V EN

SUPER TRAINER EZT SERIES

S Fault Indicators. S.T.A.R. Type CR Faulted Circuit Indicator Installation Instructions. Contents PRODUCT INFORMATION

Ready for your dog to become a quiet family member? Let s get started.

Elite Big Dog Spray Bark Control

Please read this entire guide before beginning

Examining and Medicating the Ears of Your Cat

Product Manual. PBC Bark Collar. Please read this entire Product Manual before beginning.

Are my trawl wires marked correctly? Is my trawl spread optimally? Is the trawl on bottom?

400 Yard Trainer GDT Product Manual

Operating Guide. Please read this entire guide before beginning

PetSafe Big Dog Spray Bark Control Collar

Guide for Incubation of Eggs and Care of Newborn Livestock

The Other Door Steel Crate

GARNET STATIC SHOCK BARK COLLAR

Some important information about the fetus and the newborn puppy

FCI LT LM UNDERGROUND

300 Yard Trainer GDT Product Manual

APPLICATION FOR LIVE ANIMAL USE IN TEACHING AT COASTAL ALABAMA COMMUNITY COLLEGE

Basic Assistance Harness Pricing & Measuring

Getting Started. Device Overviews. Setting Up the Pro 550 System Before you can use the Pro 550 system, you must set up the devices.

PetSpy Advanced Dog Training System, Model M86N

AmpFlex Flexible Current Probes

Essential Skills for Assistant Training Revised 7/1/2018

COOPER POWER SERIES. S.T.A.R. PATHFINDER variable trip TPR faulted circuit indicator installation instructions. Fault indicators MN320003EN

Remote Trainer. by Dogtra Portable Remote Controlled Dog Training Collars. Owner s Manual

Programming and Installation Guide. PPA Microchip Cat Flap. Series. Please read this entire guide before beginning.

YELLOW VIBRATION BARK COLLAR

Our K9 LLC 616 Corporate Way Valley Cottage New York GARNET STATIC SHOCK BARK COLLAR USERS GUIDE

Owner s Manual. by Dogtra Portable Remote Controlled Dog Training Collars

Express Train Electronic Radio Dog Training Collar

LITTER ROBOT LITTER ROBOT. Litter-Robot Manual. The Self-Cleaning Litter Box that Really Works. Automated Pet Care Products, Inc.

Historical Summary Our Mission Our Products Exhibitions ECMA Summary Contact Details and Location

PetSafe Deluxe Bark Control

Frequently Asked Questions

Instruction Manual. The Self-Cleaning Litter Box that Really Works!

A Heated Environment Will Require Added Moisture Determine The Correct Feeding Level The Temperature Is Important And Should Be Checked At The Level

Pixie-7P. Battery Connector Pixie-7P Fuse* Motor. 2.2 Attaching the Motor Leads. 1.0 Features of the Pixie-7P: Pixie-7P Batt Motor

The Self-Cleaning Litter Box that Really Works! Instruction Manual

Getting Started. Instruction Manual

K9K-914 Anti Bark Collar User's Manual. Introduction:

SMARTKITTY SELFCLEANING LITTER BOX

Vibratory Tumbler OWNER S MANUAL

An introduction to ear cytology in small animal patients

QUICK REFERENCE GUIDE

Congratulations! Thank you for purchasing a ScoopFree. The Only Self-Cleaning Litter Box You Can Leave Alone For Weeks At A Time

by Dogtra Portable Remote Controlled Dog Training Collars Owner s Manual

Why individually weigh broilers from days onwards?

By Dogtra Remote Controlled Dog Training Collars. Owner's Manual. Please read this manual thoroughly before operating the Dogtra 280C training collar.

Training Module No 2

RISK CONTROL SOLUTIONS

Congratulations on the purchase of your

GARNET STATIC SHOCK BARK COLLAR

HALE SECURITY PET DOOR CAT GUARDIAN patent pending

advanced bark control collar INSTRUCTION Manual

CONGRATULATIONS! Product Specifications Owner s Registration Reply Card

Elite Bark Control PBC operating and training guide. Big Dog Model Number. Little Dog Model Number

Excellence Assured Pet Retailer Scheme Audit Standards Criteria

APPLICATION FOR LIVE ANIMAL USE IN TEACHING AT COASTAL ALABAMA COMMUNITY COLLEGE

Ultrasonic Bark Control Collar

-1- Please refer to the SAFETY INSTRUCTIONS portion of this manual

Table of Contents Operating Guide Training Guide

Dr Nick Hill. Contents. Our mission is to develop products which educate and empower owners to provide a higher level of care for their pets.

Important Safety Information. Table of Contents

Installation Instructions

Simrad ITI Trawl monitoring system

By Dogtra Remote Controlled Dog Training Collars. Owner's Manual. Please read this manual thoroughly before operating the Dogtra EDGE training collar.

R&J Enterprises Green Cove Springs, FL Rjaquatics.com

Microchip Cat Flap. Instruction Manual Gebrauchsanweisung Hadleiding Notice D utilisation Brugervejledning

Guidelines for the administration of SureSeal

Welcome to the World of Patpet.com. 620 Series. Remote Dog Training Collar

Approved Cat Enrichment Items

Our Automatic pet feeder works for all sizes pets such as dogs, ferrets, pigs, deer etc.

Meow for Now Foster Care Guide

Assuring Quality: A guide for youth livestock producers Activity for 2008

Contents. Introduction...Page 3. Safety Instructions...Page 4. Before You Commence Installation...Page 5. Measuring Up...Page 6

ultrasmart receiver collar

TECHNICAL CHARACTERISTICS CT 014

BQSAP. Section 1. d. None of the above

Aqua-20 Goldfish Kit User Manual Warranty

Owner s Manual DOGS (3647)

New Model. Digital Mastitis Detector. Reduce of risk at early stage

Delta Upland Owner s Manual

Transcription:

Pet-Temp PT-300 Ear Thermometer Frequently Asked Questions 1) Is the Pet-Temp accurate? Yes, the Pet-Temp has a laboratory (in vitro) accuracy of 0.2 C (0.3 F). Clinical studies have verified the accuracy of the Pet-Temp. A recent clinical study conducted at the University of Missouri, Columbia and published in JAVMA concluded Our results revealed that the animal ear thermometer yields an accurate assessment of body temperature (JAVMA, Vol. 221, No. 3, August 1, 2002). Another clinical study at the San Diego Humane Society has verified in vivo accuracy on dogs and cats (right ear to glass rectal SD=0.68 F, left ear to glass rectal SD=0.59 F). When comparing ear temperatures of the Pet-Temp with rectal temperatures taken with either a glass or digital electronic thermometer, the Pet-Temp will typically read in the same range and will trend in the same direction. For clinical purposes, when used correctly, the Pet-Temp gives readings that are similar to rectal readings, however, the Pet-Temp will not be perfectly equal to rectal temperatures for the following reasons: A. Rectal temperatures are different from core temperatures. Studies on animals and humans have shown that the rectum is not a perfect indicator of core body temperature. It is believed that this is due to the distance of the rectum from the core areas of the body along with the bacterial action inside the intestines and rectum. If the core body temperature is stable, the Pet-Temp and the rectal readings will typically be similar. If the core body temperature is not stable, there may be some variance between the Pet- Temp and the rectal readings. In these situations, the Pet-Temp will be more accurate than the rectal temperature because the Pet-Temp measure core body temperature changes immediately and the rectum does not. B. Accuracy of rectal temperature measurements with a glass or digital electronic thermometer depends on a number of factors including: How long the thermometer is in the rectum. The type and calibration of the thermometer. In checking new digital and glass thermometers at in an extremely accurate water bath reference, these rectal thermometer typically are mis-calibrated anywhere from 0.2 to 1.0 degree Fahrenheit. The success in having the thermometer bulb stay in contact with the rectal tissue.

If there is air in the animal's bowels, the thermometer may not make good contact with the tissue and this can lead to low readings. This lack of contact will also occur on anesthetized animals because of relaxation of the sphincter. Even with the normal variances between ear and rectal, the Pet-Temp gives the clinician an accurate indication of the animal's temperature range: hypothermic, normothermic or hyperthermic. To get an accurate reading on animals, the user must first pull the ear (pinna) out and down while inserting the probe as deep as possible in the ear and pointing the probe tip towards the angle of the opposite jaw (below the opposite ear and slightly forward). This technique will give the temperature of the deep horizontal canal, which is an accurate indicator of core temperature. If the probe is pointed towards the wall of the vertical canal, the reading may be low. It will take practice to become familiar with the correct technique. 3) What is the difference between the Pet-Temp and the human ear thermometers sold over the counter for home use? The Pet-Temp has been designed exclusively for animal temperature measurement. The two main design features, an extended sensor arm and a reduced probe tip diameter, allow the sensor probe to be positioned at the animal's horizontal ear canal for accurate readings. Human ear thermometers were designed specifically for human ear anatomy, which is different than that of most animals. The Pet-Temp has also been designed for high volume professional use such as that found in a busy animal health care facility. The over-the-counter human ear thermometers are intended for very limited (occasional) use found in a home environment. With battery replacement (every 3-5 years) the Pet-Temp should last for over 100,000 temperatures. The expected lifetime of a typical human consumer ear thermometer is only a few thousand temperatures - not nearly enough for a busy veterinary practice. 4) On What size animals will it work? Clinical data validates that the Pet-Temp works effectively on dogs and cats of all sizes. It has been used on kittens as small as 4 weeks and on large dogs that weigh 150 pounds. It is routinely used on many exotic animals such as ferrets, rabbits, chinchillas and guinea pigs. It is not recommended for full grown horses or cows. 6) Do I have to point the Pet-Temp at the tympanic membrane to get an accurate temperature (or from what part of the ear does the Pet-Temp take the temperature)? The Pet-Temp does not have to be pointed exactly towards the tympanic membrane; however it should be pointed down the horizontal canal and in the general direction of the tympanic membrane. We recommend an "ear tug" (as in standard otoscope technique), to align the vertical canal with the horizontal canal. The Pet-Temp should be seated as deep as possible

while pointing towards the angle of the opposite jaw. It will take practice to become familiar with the correct technique. 7) Why use the tympanic membrane or eardrum as a measuring site? The tympanic membrane region shares the blood supply of the brain. For this reason, it gives a brain blood temperature and is more accurate than a rectal temperature. Because the rectum is not located near the brain and due to naturally occurring digestive processes that generate heat, the temperature of the rectum may not be a good indicator of "brain blood" temperature. In a paper titled Brain, Blood and Rectal Temperature During Whole Body Cooling, James P. Kiley concluded that "rectal temperature cannot be used as an accurate measure of brain or arterial blood temperature." 8) Will ear wax affect the reading? For most cases, when the amount of cerumen is moderate, no. Earwax will be warmed up to the same temperature as the ear canal and will not cause inaccurate readings. If the ear debris is excessive (exudate) and the sensor has to be inserted through this material to be properly positioned, then the Pet-Temp reading will likely not reflect an accurate core temperature. It is recommended that the ear be cleaned and the temperature retaken after a five minute wait. 9) How will an ear infection affect the readings? In the clinical study that was published in JAVMA that is referenced above, ear infections had no effect on the ear temperature. However, if an animal has a severe ear infection, using the Pet- Temp may be contraindicated due to sensitivity of the ear canal. Advanced Monitors recommends that when an animal has an injured or infected ear, the clinician should take the temperature from the other ear. If both ears are infected and sensitive, the clinician may have to resort to a traditional rectal temperature. 10) Over what ambient temperature range will the Pet-Temp work? The room or outside air temperature range of the Pet-Temp is from 50 to 104 F (10 to 40 Celsius). However the thermometer must be given sufficient time to equalize to the new ambient temperature if moved from a hot to cold environment or vice versa. 11) What is the patient temperature range? The patient temperature range is 93 to 109 F (34 to 42.8 C). 12) How long does it take for the Pet-Temp to register a temperature? One second.

13) How do I know when the Pet-Temp is finished taking a temperature? A short audible beep indicates the completion of the measurement. 14) What type of maintenance is required? The Pet-Temp and the optical window should be kept clean and dry. The Pet-Temp can be cleaned with a soft cloth dampened with soap and water. The optical probe window should be cleaned every day, or when soiled, with alcohol and a cotton swab. After cleaning the optical window, the user should wait at least five minutes after cleaning and drying the optical window before taking a temperature. 15) Can the Pet-Temp register temperature in Fahrenheit and Celsius? Yes, there is a switch that will change between Fahrenheit and Celsius. To change from F to C or vice versa, push the C/F switch found next to the LCD with the end of a paper clip. 16) Do I need to use a probe cover? Absolutely! The Pet-Temp's calibration is based on having a probe cover installed. Failure to use a cover will lead to inaccurate readings. The probe cover is also designed to keep the probe optical window free from dirt and ear wax. If the Pet-Temp probe is inserted in the ear without a probe cover the optical window can also become damaged. Also, the probe cover prevents the transmission of infection from one animal to another. 17) Do I need to use a new probe cover every time? Absolutely! Re-using a probe cover will lead to low temperature readings. This is because earwax will solidify on the cover and block the heat waves, which will cause a low infrared signal. Also, re-using a previously used probe cover may result in transmitting an infectious agent from one animal to another. 18) How long will the built-in battery last? The life span of the battery is over 20,000 temperatures, with a shelf life of up to 10 years. If the Pet-Temp were used 20 times a day, 6 days per week, the battery would last approximately 4 years. Although, more extensive thermometer usage may somewhat shorten the life of the battery. 19) How do we replace the battery after it has lost its efficacy? For battery replacement, The Pet-Temp must be returned to. Please contact Advanced Monitors at 877-838-8367 x102 or at 858-536-8237 x102 for current pricing. This charge will include any other repairs, reconditioning and recalibration that the instrument may require. will either replace the battery or replace the thermometer with a comparable device at the Company's discretion.

20) What is the warranty of the Pet-Temp? The Pet-Temp thermometer has a limited warranty for one year from the date of purchase. During the warranty period, will either replace the battery or replace the thermometer with a comparable device at the Company's discretion. 21) What is the policy for warranty repair returns? If a Pet-Temp is within the warranty period, it will be repaired or replaced at no charge at Advanced Monitors discretion. For a warranty repair, the user must contact Advanced Monitors Corporation's Customer Service toll free at 877-838-8367 x102 to receive a Return Material Authorization (RMA) number. Once the RMA is issued, this number should be written on the outside of the shipping case and then the thermometer should be sent back to Advanced Monitors Corporation. This assures prompt repair and return shipment. 22) What is the policy for out-of-warranty repairs? offers a discount for the purchase of a new Pet-Temp thermometer if the customer s thermometer stops working outside the warranty period. For an out-of-warranty repair or replacement, please contact 's Customer Service toll free at 877-838-8367 x102 or 858-536-8237 x102 to get the latest pricing.