all access Neurovascular guide

Similar documents
Codman Neurovascular Product Portfolio

No Sacrifice of Pushability or Torquability = More Control

No Sacrifice of Pushability or Torquability = More Control

Standard Angiographic Catheters

INSTRUCTIONS FOR USE FOR:

INSTRUCTIONS FOR USE FOR: English

The only device incorporating infrarenal anchors for active fixation with proven migration prevention through 5 years of follow-up.

RADIAL APPROACH ACCESSORIES Rad Board Radial Arm Board 3 Rad Board Accessories 3-4 Rad Board Xtra 3 Rad Trac 4 Rad Rest 4

GASTRO-INTESTINAL (ENTERAL)

GASTRO-INTESTINAL (ENTERAL)

Legend. Reusable. Rotatable. Disposable. Thickness in released position. Internal diameter in released position. Cup opening.

Features & Benefits WITHOUT VENT PLUG/ RED CAP WITH VENTED WITH VENT PLUG. 20 Fr 33cm A2016 A2016V 24 cm B2016 B2016V

VALUE ANALYSIS and PRODUCT INFORMATION KIT

Kit-Construction block

Electromagnetic flowmeters. dg: NEW. Sensors MUT 2200 EL / MUT 2500 EL DS100-4-ENG 1/14

Ensure you have the right acute CVC for any treatment and every patient.

Plastic bile duct stents Stents only, introducer-systems and preloaded stents.

TRUCK PUMPS HYDRAULIC GEAR PUMPS

Vascular and Cardiothoracic Surgery Solutions

In this guide: Technology Overview. Proven Technology

Drinking Systems for Breeders & Pullets

Complete Range of Watering Systems for Breeders & Pullets

Exceptional fossil preservation demonstrates a new mode of axial skeleton elongation in early ray-finned fishes

Discovery. DIFFERENTIAL DIAGNOSES Septic joint or tendon sheath Abscess Vascular damage Fracture Tendon or ligament damage

Advancing Lives and the Delivery of Health Care

EX3 Stepper-Motor Driven Electronic Expansion Valve Technical Data

trusted security Roth Net retrieval devices

Pressure Tanks. ASME Code Stainless Steel, Galvanized and ASME PT Series Tanks. A R 10/11

For quality & safety. Type Composition Coating Colour Tissue reaction Absorption Presentation

HONR219D Due 3/29/16 Homework VI

SOME LITTLE-KNOWN FOSSIL LIZARDS FROM THE

FURTHER STUDIES ON TWO SKELETONS OF THE BLACK RIGHT WHALE IN THE NORTH PACIFIC

SILVER SCOPE Veterinary Videoendoscopes

CAT DISSECTION A LABORATORY GUIDE

IEEE Std 592 Test Program using Current Cable Accessories and Installation Practices

Regional and Local Anesthesia of the Wrist and Hand Aided by a Forearm Sterile Elastic Exsanguination Tourniquet - A Review

CSA6. Product Specifications. SoftSound SXC 2600

SUPPLEMENTARY ONLINE MATERIAL FOR. Nirina O. Ratsimbaholison, Ryan N. Felice, and Patrick M. O connor

Single Port Modular Jacks

Natural Gas.

EXQUISITELY DESIGNED AQUARIUMS FOR ALL EXPERIENCE LEVELS.

Australian College of Veterinary Scientists Fellowship Examination. Veterinary Anaesthesia and Critical Care Paper 1

Hillside Cultivator Co. LLC Prices and Parts

MEDICATION ADMINSITRATION: ANTIBIOTIC LOCK THERAPY GUIDELINE

Education & Training Plan. Veterinary Office Assistant Specialist Certificate Program

HADDENHAM CUSTOM MEASUREMENT INSTRUCTIONS

EC-AH-011v1 January 2018 Page 1 of 5. Standard Operating Procedure Equine Center Clemson University

Dogs On Course in North America, LLC Agility Equipment Specifications

NATURA CAGE-FREE. Modern aviary system for barn and free range egg production

Seattle Humane s. 27th Annual. May 7, 2016 Hyatt Regency Bellevue Auction Dinner Pet Runway Show. seattlehumane.org/tuxes. Sponsorship Opportunities

MORPHOMETRIC ANALYSIS OF INFRA ORBITAL FORAMEN IN HUMAN DRY SKULLS

STRUTTURA UOMO MANUALE DI ANATOMIA ARTISTICA VOL. 1 (MANUALE DI ANATOMIA ARTISTICA, VOLUME 1) BY NERI POZZA

Sites of IM injections : 1. Ventrogluteal site: site is in the gluteus medius muscle, which lies over the gluteus minimus. 2. Vastus lateralis site:

Judging the Doberman Head By Bob Vandiver

August Specials. Summer Suture Sale! In August, suture cassettes are 10% off. 10% off Splints. August 2018 Volume 22 Issue 8

Premium Carbide Burrs

Air Receivers TECHNOLOGY YOU CAN TRUST

Supplementary Information for: 3D morphometric analysis of fossil canid skulls contradicts

TOTAL CONCRETE CORE SOLUTIONS

Manufacturing Programme/Load Tables. FischerKASSETTE. * An enterprise of Tata Steel

Part Number: CAT6+ UTP PVC PATCH CORDS CAT6+ Patch Cord, UTP, PVC

The Cat Sentence-Building Exercise 1

Poultry Watering Systems Catalogue

PLEASE POST. EMS Providers are to ensure that all EMS personnel receive this information.

NEW PRODUCTS SCANLAN TITANIUM LEGACY FORCEPS LILLEHEI-POTTS TENOTOMY SCISSORS...1.4

Patient Preparation. Surgical Team

S M ALL. Up to 45 dbrw* Height 2.5 m. Custom layout* Air cooling* Height 2.2 m. Space capacity. Easy access. For 1 person. Up to. 2 persons.

Part Number: CAT6+ UTP PVC PATCH CORDS CAT6+ Patch Cord, UTP, PVC

FREQUENTLY ASKED QUESTIONS Pet Owners

The DOG Sentence-Building Exercise 1

TRAINING BULLETIN #147

OIE Standards on biosecurity and compartmentalisation

Price list - effective 1/2017

DRAFT TANZANIA STANDARD

COOPER POWER SERIES. S.T.A.R. Type ER faulted circuit indicator installation instructions. Fault Indicators MN320006EN

Inverter Multi Split System

SUTURE MATERIALS EDITION For quality & safety.

DEVELOPMENT OF THE HEAD AND NECK PLACODES

The Papillon Presented by: The Papillon Club of America, Inc.

Proceeding of the SEVC Southern European Veterinary Conference

Williston, and as there are many fairly good specimens in the American

Our Automatic pet feeder works for all sizes pets such as dogs, ferrets, pigs, deer etc.

Antimicrobial Stewardship Strategy: Intravenous to oral conversion

LABRADOR RETRIEVER: LABRADOR RETRIEVER TRAINING - COMPLETE LABRADOR PUPPY TRAINING GUIDE, OBEDIENCE, POTTY TRAINING, AND CARE TIPS (RETRIEV

SOUTH AFRICAN QUALIFICATIONS AUTHORITY REGISTERED UNIT STANDARD: Apply advanced breeding practices for farm animals

Baytril 100 (enrofloxacin) Injectable is FDA-approved for BRD control (metaphylaxis) in high-risk cattle.

Kidney, Liver, Gall, Urology

COMPLIANCE WITH THIS DOCUMENT IS MANDATORY

Crile Wood Needle Holder. Colvin Needle Holder

Poultry Watering Systems Catalogue

CODING GUIDELINES CODING GUIDELINES - OPCS NEW PAIR CODES...6 ERRATA...7. No. 18 May, 2006

Basic Assistance Harness Pricing & Measuring

ISO INTERNATIONAL STANDARD

Frog Dissection Information Manuel

2019 OPTIONS FOR INDIVIDUAL MEASURES: MIPS CLINICAL QUALITY MEASURES (CQMS) MEASURE TYPE: Process High Priority

Name Class Date. After you read this section, you should be able to answer these questions:

CLASSES OFFERED. ENTRIES CLOSE ON MONDAY, 15 October 2018 AT 8PM

Saunders Veterinary Anatomy Coloring Book, 1e PDF

Your Regional Area Closing Date: Friday, April 3 rd Final Closing Date to Enter Either Region: Friday, April 10 th

MGL Avionics EFIS G2 and iefis. Guide to using the MGL RDAC CAN interface with the UL Power engines

Transcription:

all access Neurovascular guide

Introduction... 3 Guiding Catheters Ordering Information... 4 Guiding Catheters 5F... 6 Guiding Catheters 6-8F... 7 Guidewires Ordering Information... 8 Guidewires -10... 9 Guidewires -14... 10 Microcatheters Ordering Information... 12 Microcatheters -10/Flow Directed... 13 Microcatheters -14... 14 Microcatheters -18... 15 French Conversion Chart... 16 Anatomy... 18

This All Access Neurovascular Guide is provided as a comprehensive reference for Codman Neurovascular s Access product portfolio and a comparison of other Access offerings available on the market today. This helpful guide also includes ordering information, anatomical reference illustrations, and a French conversion scale. We hope that you find this guide beneficial in the specialized selection of Access products for your practice. Please turn to the back page of this guide for Codman Neurovascular and Micrus Endovascular Customer Service information. 3

4 GUIDing CATHETERS Ordering Information ENVOY Guiding Catheters ENVOY 5 French ENVOY 6 French ENVOY XB 6 French 55626090 ENVOY 5F, STR 90 cm 67026090 ENVOY 6F, STR 90 cm 67026090B ENVOY 6F, XB STR 90 cm 55626000 ENVOY 5F, STR 100 cm 67026000 ENVOY 6F, STR 100 cm 67026000B ENVOY 6F, XB STR 100 cm 55625690 ENVOY 5F, MPC 90 cm 67025690 ENVOY 6F, MPC 90 cm 67025690B ENVOY 6F, XB MPC 90 cm 55625600 ENVOY 5F, MPC 100 cm 67025600 ENVOY 6F, MPC 100 cm 67025600B ENVOY 6F, XB MPC 100 cm 55625890 ENVOY 5F, MPD 90 cm 67025890 ENVOY 6F, MPD 90 cm 67025890B ENVOY 6F, XB MPD 90 cm 55625800 ENVOY 5F, MPD 100 cm 67025800 ENVOY 6F, MPD 100 cm 67025800B ENVOY 6F, XB MPD 100 cm 55625090 ENVOY 5F, CBL Burke 90 cm 67025090 ENVOY 6F, CBL Burke 90 cm 67025090B ENVOY 6F, XB CBL Burke 90 cm 55625000 ENVOY 5F, CBL Burke 100 cm 67025000 ENVOY 6F, CBL Burke 100 cm 67025000B ENVOY 6F, XB CBL Burke 100 cm 55625490 ENVOY 5F, H1 90 cm 67025490 ENVOY 6F, H1 90 cm 67025490B ENVOY 6F, XB H1 90 cm 55625400 ENVOY 5F, H1 100 cm 67025400 ENVOY 6F, H1 100 cm 67025400B ENVOY 6F, XB H1 100 cm 67025290 ENVOY 6F, SIM2 90 cm 67025290B ENVOY 6F, XB SIM2 90 cm 67025200 ENVOY 6F, SIM2 100 cm 67025200B ENVOY 6F, XB SIM2 100 cm XB - Extra-Backup Support Straight Multipurpose C Multipurpose D Modified Simmons 2 Headhunter 1

GUIDing CATHETERS Ordering Information NEUROPATH Guiding Catheters NEUROPATH 5 French NEUROPATH 6 French GCB51000000 NEUROPATH 5F, CBL Burke 100 cm GCB61000000 NEUROPATH 6F, CBL Burke 100 cm GCB50900000 NEUROPATH 5F, CBL Burke 90 cm GCB60900000 NEUROPATH 6F, CBL Burke 90 cm GSM51000000 NEUROPATH 5F, SIM2 100 cm GSM61000000 NEUROPATH 6F, SIM2 100 cm GSM50900000 NEUROPATH 5F, SIM2 90 cm GSM60900000 NEUROPATH 6F, SIM2 90 cm GHH51000000 NEUROPATH 5F, H1 100 cm GHH61000000 NEUROPATH 6F, H1 100 cm GHH50900000 NEUROPATH 5F, H1 90 cm GHH60900000 NEUROPATH 6F, H1 90 cm GMC51000000 NEUROPATH 5F, MPC 100 cm GMC61000000 NEUROPATH 6F, MPC 100 cm GMC50900000 NEUROPATH 5F, MPC 90 cm GMC60900000 NEUROPATH 6F, MPC 90 cm GMD51000000 NEUROPATH 5F, MPD 100 cm GMD61000000 NEUROPATH 6F, MPD 100 cm GMD50900000 NEUROPATH 5F, MPD 90 cm GMD60900000 NEUROPATH 6F, MPD 90 cm GST51000000 NEUROPATH 5F, STR 100 cm GST61000000 NEUROPATH 6F, STR 100 cm GST50900000 NEUROPATH 5F, STR 90 cm GST60900000 NEUROPATH 6F, STR 90 cm Straight Multipurpose C Multipurpose D Modified Simmons 2 Headhunter 1 5

GUIDing catheters 5 French STRYKER Penumbra TERUMO COOK 6 Guiding catheter Name ENVOY 5F NEUROPATH 5F Guider Softip Neuron 5F Chaperon 5F System Shuttle 5F Sheath Size 5F 5F 5F 5F 5F 5F Usable Length 90 cm and 100 cm 90 cm and 100 cm 90 cm and 100 cm 120 cm and 130 cm 95 cm n/a Shaft Size OD 5F 5F 5F 5F 5F 0.090 Shaft Size ID 0.056 0.057 0.053 0.040 0.059 0.074 Tip Shape Straight, MPC, MPD, Modified, Headhunter 1 MPD, MPC, Straight, Simmons 2, Headhunter 1, Modified Cerebral Straight, MP, 40 H1, SIM, Ber Straight, MP1, MP2, BUR JB2, VTK, H1, SIM2, JB1

GUIDing catheters 6-8 French STRYKER Penumbra TERUMO COOK STRYKER STRYKER Guiding catheter Name ENVOY 6F NEUROPATH 6F Guider Softip Neuron 6F Chaperon 6F System Shuttle 6F Sheath Guider Softip Guider Softip Size 6F 6F 6F 6F 6F 6F 7F 8F Usable Length 90 cm and 100 cm 90 cm and 100 cm 90 cm and 100 cm 95 cm, 105 cm and 115 cm Shaft Size OD 6F 6F 6F Proximal: 6F Distal: 5F or 6F Shaft Size ID 0.070 0.070 0.064 0.053 and 0.070 Tip Shape Straight, MPC, MPD, Modified, Simmons 2, Headhunter 1 MPD, MPC, Straight, Simmons 2, Headhunter 1, Modified Cerebral Straight, MP, 40 Straight and MP Straight, MP1, MP2, BUR 95 cm n/a 90 cm and 100 cm 6F 0.104 7F 8F 90 cm and 100 cm 0.071 0.087 0.073 0.086 JB2, VTK, H1, SIM2, JB1 Straight, MP, 40 Straight, MP, 40 Data on file at Codman & Shurtleff, Inc. 7 Guiding Catheters

8 GUIDEWIRES Ordering Information NEUROSCOUT 14 Steerable Guidewires 601314 NEUROSCOUT 0.014 205 cm Standard 601315 NEUROSCOUT 0.014 300 cm Standard XL 601414 NEUROSCOUT 0.014 205 cm Soft 601415 NEUROSCOUT 0.014 300 cm Soft XL AGILITY Steerable Guidewires 614178 AGILITY 0.010 195 cm Standard 614179 AGILITY 0.010 195 cm Soft 614481 AGILITY 0.014 205 cm Standard 614482 AGILITY 0.014 205 cm Soft 614491 AGILITY 0.014 350 cm Standard XL 614541 AGILITY 0.016 175 cm Standard 614542 AGILITY 0.016 175 cm Soft 614581 AGILITY 0.016 205 cm Standard

10 GUIDEWIRES 14 Guidewire Name NEUROSCOUT 14 Soft NEUROSCOUT 14 Soft XL NEUROSCOUT 14 Standard NEUROSCOUT 14 Standard XL STRYKER STRYKER STRYKER STRYKER STRYKER Synchro 2 Transend EX-14 Standard Transend EX-14 Soft Transend EX-14 Floppy Outer Diameter 0.014 0.014 0.014 0.014 0.014 0.014 0.014 0.014 0.014 Overall Length 205 cm 300 cm 205 cm 300 cm 200 and 300 cm 182 cm 205 cm 205 cm 205 cm Distal Taper Length 43 cm 43 cm 42 cm 42 cm 35 cm 26 cm 26 cm 26 cm 26 cm Coil Length 10 cm 10 cm 10 cm 10 cm 10 cm None None None 3 cm Radiopaque Length 10 cm 10 cm 10 cm 10 cm 10 cm 39 cm 39 cm 39 cm 39 cm Coated Length 170 cm 170 cm 170 cm 170 cm 200 and 300 cm 182 cm 205 cm 205 cm 205 cm Core Wire Material SST SST SST SST SST SST SST SST SST Transend EX-14 Platinum Coil Material Platinum/Tungsten Platinum/Tungsten Platinum/Tungsten Platinum/Tungsten Platinum/Tungsten None None None Platinum Coating Hydrophilic Hydrophilic Hydrophilic Hydrophilic Hydrophilic distal, PTFE proximal Microcatheter Compatibility 0.0165, 0.0170, 0.021 0.0165, 0.0170, 0.021 0.0165, 0.0170, 0.021 0.0165, 0.0170, 0.021 0.0165, 0.0170, 0.021 Hydrophilic distal, PTFE proximal 0.0165, 0.0170, 0.021 Hydrophilic distal, PTFE proximal 0.0165, 0.0170, 0.021 Hydrophilic distal, PTFE proximal 0.0165, 0.0170, 0.021 Shapeable Tip 1.5 cm 1.5 cm 1.5 cm 1.5 cm 1 cm 2 cm 2 cm 2 cm 2 cm Hydrophilic distal, PTFE proximal 0.0165, 0.0170, 0.021

GUIDEWIRES 14 Guidewire Name AGILITY 14 Soft AGILITY 14 Standard Outer Diameter 0.014 0.014 Proximal: 0.014 Distal: 0.012 TERUMO TERUMO TERUMO COVIDIEN COVIDIEN Traxcess Glidewire Gold Headliner 12 Floppy, Standard 0.014, 0.016, 0.018 SILVERSPEED 14 X-pedion 14 0.012 0.014 0.014 Overall Length 205 cm 205 cm 200 cm 180 cm 200 cm 175 and 200 cm 200 cm Distal Taper Length 45 cm 42 cm 40 cm 8 cm 20 and 35 cm 15 cm 20 cm Coil Length 20 cm 10 cm 3 cm 2 mm 2 cm 20 cm 20 cm Radiopaque Length 20 cm 10 cm 3 cm 2 mm 2 cm n/a n/a Coated Length 170 cm 170 cm 200 cm 180 cm 200 cm 145 and 170 cm 170 cm Core Wire Material SST SST Nitinol Nitinol Nitinol SST n/a Coil Material Platinum/Tungsten Platinum/Tungsten Platinum Gold Gold Platinum Platinum Coating Hydrophilic Hydrophilic Hydrophilic distal, PTFE proximal Hydrophilic Hydrophilic Hydrophilic distal, PTFE proximal Hydrophilic distal, PTFE proximal Microcatheter Compatibility 0.0165, 0.0170, 0.021 0.0165, 0.0170, 0.021 0.0165, 0.0170, 0.021 0.0165, 0.0170, 0.021 0.0165, 0.0170, 0.021 0.0165, 0.0170, 0.021 0.0165, 0.0170, 0.021 Shapeable Tip 2 cm 2 cm 1.4 cm 3 and 5 cm Preshaped (45, 90, 150, double 1.5 mm J-tip) n/a n/a Data on file at Codman & Shurtleff, Inc. 11 Guidewires

MICROCATHETERS 12 Ordering Information TRANSIT Microcatheters 600330 TRANSIT 135 cm 600350A TRANSIT 150 cm RAPIDTRANSIT Microcatheters 601210 RAPIDTRANSIT 70 cm, 1MB 601251 RAPIDTRANSIT 150 cm, 1MB 601271 RAPIDTRANSIT 170 cm, 1MB 601251X RAPIDTRANSIT 150 cm, 2MB PLUS - Larger ID LP - Low Profile ES - Extra Support COURIER Microcatheters PROWLER SELECT LP-ES Microcatheters MST17000000 COURIER 150/24 cm, Straight, 2MB 606S155X PROWLER SELECT LP-ES 150/5 cm, Straight, 2MB MPS17004500 COURIER 150/24 cm, 45, 2MB 606S155FX PROWLER SELECT LP-ES 150/5 cm, 45, 2MB MPS17009000 COURIER 150/24 cm, 90, 2MB 606S155MX PROWLER SELECT LP-ES 150/5 cm, 90, 2MB MST19000000 COURIER 150/24 cm, Straight, 2MB 606S155JX PROWLER SELECT LP-ES 150/5 cm, J, 2MB MPS19004500 COURIER 150/24 cm, 45, 2MB PROWLER Plus Microcatheters MPS19009000 COURIER 150/24 cm, 90, 2MB 6062310 PROWLER Plus 135/20 cm, Straight, 1MB PROWLER 10 Microcatheters 6062510 PROWLER Plus 150/20 cm, Straight, 1MB 606051 PROWLER-10 150/50 cm, Straight, 1MB 6062510X PROWLER Plus 150/20 cm, Straight, 2MB 606051X PROWLER-10 150/50 cm, Straight, 2MB 6062511 PROWLER Plus 150/45 cm, Straight, 1MB 606051mx PROWLER-10 150/50 cm, 90, 2MB 6062511X PROWLER Plus 150/45 cm, Straight, 2MB 606051jx PROWLER-10 150/50 cm, J, 2MB 6062510MX PROWLER Plus 150/20 cm, 90, 2MB 606051fx PROWLER-10 150/50 cm, 45, 2MB 6062510JX PROWLER Plus 150/20 cm, J, 2MB PROWLER 14 Microcatheters 6062510fX PROWLER Plus 150/20 cm, 45, 2MB 606151 PROWLER-14 150/50 cm, Straight, 1MB 6062511FX PROWLER Plus 150/45 cm, 45, 2MB 606151X PROWLER-14 150/50 cm, Straight, 2MB 6062910 PROWLER Plus 110/20 cm, Straight, 1MB 606171 PROWLER-14 170/50 cm, Straight, 1MB PROWLER SELECT Plus Microcatheters 606151MX PROWLER-14 150/50 cm, 90, 2MB 606S252 PROWLER SELECT Plus 150/15 cm, Straight, 1MB 606151JX PROWLER-14 150/50 cm, J, 2MB 606S252FX PROWLER SELECT Plus 150/15 cm, 45, 2MB 606151FX PROWLER-14 150/50 cm, 45, 2MB 606S252X PROWLER SELECT Plus 150/15 cm, Straight, 2MB 606S255FX PROWLER SELECT Plus 150/5 cm, 45, 2MB 606S255JX PROWLER SELECT Plus 150/5 cm, J, 2MB 606S255MX PROWLER SELECT Plus 150/5 cm, 90, 2MB 606S255X PROWLER SELECT Plus 150/5 cm, Straight, 2MB

Microcatheters 10 Flow-Directed Microcatheters COVIDIEN COVIDIEN Microcatheter Name PROWLER 10 Microcatheter Name MARATHON ULTRAFLOW Reinforced Construction SST braid/platinum coil Reinforced Construction SST Coil/Nitinol braid n/a Shaft Size OD Proximal: 2.3F Distal: 1.7F Shaft Size OD Proximal: 2.7F Distal: 1.5F Proximal: 3.0F Distal: 1.5F Shaft Size ID 0.015 Shaft Size ID Proximal: 0.015 Distal: 0.013 0.012 and 0.013 Usable Length 150 cm Usable Length 165 cm 165 cm Flexible Tip Length 50 cm Flexible Tip Length 25 cm 35 or 42 cm Hydrophilic Coating Hydrophilic Hydrophilic Coating n/a Hydrophilic Inner Liner PTFE liner Inner Liner PTFE liner n/a Dead Space 0.32 cc Dead Space 0.23 cc 0.26cc Rated Burst Pressure 300 psi Rated Burst Pressure n/a n/a Tip Shape Straight, 45, 90 & J Tip Shape n/a Steam shapeable Tip Configuration 1 or 2 markers Tip Configuration 1 marker 1 marker Min. Guiding Catheter ID 0.035 Min. Guiding Catheter ID n/a n/a Max. Guidewire OD 0.012 Max. Guidewire OD 0.010 0.010 Coil Sizes * 0.010 Coil Sizes n/a n/a *Prior to coil use, refer to selected coil Instructions for Use supplied with the product for compatibility information. Data on file at Codman & Shurtleff, Inc. 13

14 Microcatheters 14 STRYKER COVIDIEN TERUMO Microcatheter Name PROWLER 14 PROWLER LP-ES COURIER 170 EXCELSIOR SL-10 ECHELON 10 HEADWAY 17 Reinforced Construction SST braid/platinum coil SST braid/platinum coil SST braid/sst coil Shaft Size OD Proximal: 2.3F Distal: 1.9F Proximal: 2.3F Distal: 1.9F Proximal: 2.3F Distal: 1.8F Coiled proximal to distal tip Proximal: 2.4F Distal: 1.7F Variable flatwire/nitinol braid Proximal: 2.1F Distal: 1.7F SST/Nitinol distal core Proximal: 2.4F Distal: 1.9F Shaft Size ID 0.0165 0.0165 0.0170 0.0165 0.017 0.017 Usable Length 150 or 170 cm 150 cm 150 cm 150 cm 150 cm 150 cm Flexible Tip Length 50 cm 5 cm 24 cm 6 cm 22 cm n/a Hydrophilic Coating Hydrophilic Hydrophilic Hydrophilic Hydrophilic Hydrophilic Hydrophilic Inner Liner PTFE liner PTFE liner PTFE liner PTFE liner PTFE liner PTFE liner Dead Space 0.35-0.38 cc 0.35 cc 0.30 cc n/a n/a 0.29 cc Rated Burst Pressure 300 psi 300 psi 300 psi 300 psi 250 psi 300 psi Tip Shape Straight, 45, 90 & J Straight, 45, 90 & J Straight, 45 & 90 Straight, 45, 90, J, C & S Straight, 45, 90 Straight, Steam Shapeable Tip Configuration 1 or 2 markers 2 markers 2 markers 1 or 2 markers 2 markers 2 markers Min. Guiding Catheter ID 0.035 0.035 0.035 0.035 0.050 0.056 Max. Guidewire OD 0.014 0.014 0.014 0.014 0.014 0.014 Coil Sizes * Up to 0.014 Up to 0.014 Up to 0.015 Up to 0.014 Up to 0.014 Up to 0.014

FRENCH CONVERSION CHART French Inches mm 1 0.013 0.330 2.6 0.034 0.858 2.7 0.035 0.891 16 1 French = 0.0131 in = 0.33 mm 1 mm = 0.0393 in = 3F 1 in = 25.4 mm = 76.2F 1.1 0.014 0.363 1.2 0.016 0.396 1.3 0.017 0.429 1.4 0.018 0.462 2.8 0.037 0.924 2.9 0.038 0.957 3 0.039 0.990 3.1 0.041 1.023 1.5 0.020 0.495 3.2 0.042 1.056 1.6 0.021 0.528 3.3 0.043 1.089 1.7 0.022 0.561 3.4 0.045 1.122 1.8 0.024 0.594 3.5 0.046 1.155 1.9 0.025 0.627 3.6 0.047 1.188 2 0.026 0.660 3.7 0.048 1.221 2.1 0.028 0.693 3.8 0.050 1.254 2.2 0.029 0.726 3.9 0.051 1.287 2.3 0.030 0.759 4 0.052 1.320 2.4 0.031 0.792 4.1 0.054 1.353 2.5 0.033 0.825 4.2 0.055 1.386

4.3 0.056 1.419 4.4 0.058 1.452 4.5 0.059 1.485 4.6 0.060 1.518 4.7 0.062 1.551 4.8 0.063 1.584 4.9 0.064 1.617 5 0.066 1.650 5.1 0.067 1.683 5.2 0.068 1.716 5.3 0.069 1.749 5.4 0.071 1.782 5.5 0.072 1.815 5.6 0.073 1.848 5.7 0.075 1.881 5.8 0.076 1.914 5.9 0.077 1.947 6 0.079 1.980 6.1 0.080 2.013 6.2 0.081 2.046 6.3 0.083 2.079 6.4 0.084 2.112 6.5 0.085 2.145 6.6 0.086 2.178 6.7 0.088 2.211 6.8 0.089 2.244 6.9 0.090 2.277 7 0.092 2.310 7.1 0.093 2.343 7.2 0.094 2.376 7.3 0.096 2.409 7.4 0.097 2.442 7.5 0.098 2.475 7.6 0.100 2.508 7.7 0.101 2.541 7.8 0.102 2.574 7.9 0.103 2.607 8 0.105 2.640 8.1 0.106 2.673 8.2 0.107 2.706 8.3 0.109 2.739 8.4 0.110 2.772 8.5 0.111 2.805 8.6 0.113 2.838 8.7 0.114 2.871 8.8 0.115 2.904 8.9 0.117 2.937 9 0.118 2.970 10 0.131 3.300 11 0.144 3.630 12 0.157 3.960 17 French Conversion Chart

18 ANATOMY Cerebral Arteries Internal Carotid Artery Anterior parietal artery Pericallosal artery Middle internal frontal artery Anterior internal frontal artery Anterior cerebral artery Middle cerebral artery Posterior parietal artery Ophthalmic artery Internal carotid artery FronTAl Lateral

Vertebral Artery Parieto-occipital artery Posterior inferior cerebellar artery Posterior cerebral artery Basilar artery Cerebral Arteries Calcarine artery Superior cerebellar artery Anterior inferior cerebellar artery Lateral CEREBRAL ARTERIES EXTERNAL CAROTID ARTERY Superficial temporal artery Maxillary artery Posterior auricular artery Occipital artery Middle meningeal artery Facial artery External carotid artery Vertebral artery Frontal Lateral 19 Anatomy

Microcatheter Indications The Codman Neurovascular TRANSIT, RAPIDTRANSIT and PROWLER Infusion Catheters are intended to be used as a mechanism for the infusion of various diagnostic, embolic, and therapeutic agents into the vascular systems outlined in Table 1 and for superelective angiography of the peripheral and coronary vasculatures. All agents must be used in accordance with manufacturer s instructions for use. COURIER Microcatheters are intended to aid in the delivery of diagnostic agents, such as contrast media, as well as therapeutic agents, such as occlusion coils, into the peripheral, coronary and neurovasculature. Table 1: Vasculature Indications Infusion Catheter Neuro Peripheral Coronary Guidewire Exchange/Support RAPIDTRANSIT ü ü ü ü TRANSIT ü ü ü ü PROWLER PLUS ü ü ü ü PROWLER SELECT PLUS ü ü ü ü PROWLER 14 ü ü ü ü PROWLER SELECT LP ü ü ü ü PROWLER SELECT LP-ES ü ü ü ü PROWLER 10 ü ü ü ü COURIER 170 ü ü ü ü COURIER 190 ü ü ü ü It is recommended that the Codman Neurovascular Infusion Catheters be used with a guide catheter, a compatible catheter sheath introducer, and a steerable guidewire. Codman & Shurtleff, Inc. 325 Paramount Drive Raynham, MA 02767 USA Tel: +1 (800) 225-0460 www.depuy.com Guidewire Indications The Codman Neurovascular NEUROSCOUT and AGILITY Steerable Guidewires are intended for selective placement of microcatheter and other devices in the neuro and peripheral vasculature. Contraindications NEUROSCOUT and AGILITY Steerable Guidewires are contraindicated for use in chronic total occlusions in the peripheral vasculature. Guide Catheter Indications The ENVOY Guide Catheter is intended for use in the peripheral, coronary, and neurovasculature for the intravascular introduction of interventional/diagnostic devices. NEUROPATH Guide Catheters are intended for use in the coronary, peripheral and neurovasculature for intravascular introduction of interventional/diagnostic devices. Call Codman Customer Service at 1-800-255-2500 to order the following products CODMAN ENTERPRISE VRD NEUROSCOUT, AGILITY, ESSENCE Guidewires ENVOY Guiding Catheters PROWLER, RAPIDTRANSIT, TRANSIT Microcatheters ORBIT GALAXY Detachable Coil System, TRUFILL DCS ORBIT Detachable Coil System, TRUFILL Pushable Coils, TRUPUSH Coil Pusher TRUFILL n-bca Liquid Embolic System For product information call 1-800-225-0460. Call Micrus Customer Service at 1-888-550-4120, Option 2 to order the following products ASCENT Occlusion Balloon Catheter NEUROPATH Guiding Catheters COURIER Microcatheters PRESIDIO, MICRUSPHERE, CASHMERE, HELIPAQ, DELTAPAQ, DELTAPLUSH, ULTIPAQ Microcoils ENPOWER Detachment Control System. For competitor information, data was compiled by Codman & Shurtleff, Inc. based on product brochures, Web sites, and IFUs. The third party trademarks shown are the trademarks of their respective owners. Codman & Shurtleff, Inc. 2011. All rights reserved. NS-01-002 9/11 ADDB/RPI