Testing Bulk Tank Milk Samples. G. M. Jones and Susan Sumner*

Similar documents
Milk Quality Evaluation Tools for Dairy Farmers

Trouble-Shooting a Mastitis Problem Herd 1

LOOKING FOR PROFITS IN MILK QUALITY

Using SCC to Evaluate Subclinical Mastitis Cows

Quality Milk. got milk? Milk Quality. Why Bacteria in Milk Matters. Bacteria in Milk. Milk.One of Mother Nature s Most Perfect Foods

Mastitis Module Risk Assessment Guide by Pathogen. Streptococcus agalactiae

2012 Indiana Regional Dairy Meetings. Purdue University College of Veterinary Medicine Dr. Jon Townsend Dairy Production Medicine

Mastitis: Background, Management and Control

Evaluation of a new qpcr test to specify reasons behind total bacterial count in bulk tank milk

Interpretation of Bulk Tank Milk Results

Milk quality & mastitis - troubleshooting, control program

Using DHIA and bacteriology to investigate herd milk quality problems.

Strep. ag.-infected Dairy Cows

Interpretation and Use of Laboratory Culture Results and the Characteristics of Various Mastitis Pathogens

Interpretation and Use of Laboratory Culture Results and the Characteristics of Various Mastitis Pathogens

TEAT DIP- POST DIP- PRE DIP- STRIPING

Dairy/Milk Testing Report Detecting Elevated Levels of Bacteria in Milk-On-Site Direct- From-The-Cow Within Minutes as Indicator of Mastitis

Summary. Table 1. Estimated infection prevalence and losses in milk production associated with elevated bulk tank somatic cell counts.

MASTITIS. Therefore, mastitis is an inflammation of the mammary gland.

MASTITIS AND ITS CONTROL

Understanding the Basics of Mastitis

Milking Management II - Mastitis 1

Milk Quality Management Protocol: Fresh Cows

MICROBIOLOGY of RAW MILK

Sources of Different Mastitis Organisms and Their Control

Dr. Michelle Arnold, DVM DABVP (Food Animal) Ruminant Extension Veterinarian University of Kentucky Veterinary Diagnostic Laboratory

New York State Cattle Health Assurance Program Fact Sheet Udder Health Herd Goals

Quality Milk on Pasture Based Dairy Farms. Scott E. Poock, DVM University of Missouri Clinical Assistant Professor DABVP Beef and Dairy Cattle

Walter M. Guterbock, DVM, MS Veterinary Medicine Teaching and Research Center University of California, Davis

How to Decrease the Use of Antibiotics in Udder Health Management

Quad Plate User s Manual

The mastitis situation in Canada where do you stand?

, Pamela L. Ruegg

MILK COMPOSITIONAL CHANGES DURING MASTITIS

Emerging Mastitis Threats on the Dairy Pamela Ruegg, DVM, MPVM Dept. of Dairy Science

8. MILK Udder health and milk quality is important to farm productivity and profitability. Every farm stands to gain from less mastitis.

Mastitis MANAGING SOMATIC CELLS COUNTS IN. Somatic Cell Count Are Affected by. Somatic Cells are NOT Affected by:

29/11/2017. Best Milking Practices. Greg Strait- Fulton County Extension Amber Yutzy- Huntingdon County Extension

MASTITIS DNA SCREENING

Mastitis Reminders and Resources LAURA SIEGLE EXTENSION AGENT VIRGINIA COOPERATIVE EXTENSION AMELIA COUNTY

Mastitis and On-Farm Milk Cultures - A Field Study - Part 1

Premiums, Production and Pails of Discarded Milk How Much Money Does Mastitis Cost You? Pamela Ruegg, DVM, MPVM University of Wisconsin, Madison

Outline MILK QUALITY AND MASTITIS TREATMENTS ON ORGANIC 2/6/12

Environmental Streptococcal and Coliform Mastitis

Guidelines for Monitoring Bulk Tank Milk Somatic Cell and Bacterial Counts

Presented at Central Veterinary Conference, Kansas City, MO, August 2013; Copyright 2013, P.L Ruegg, all rights reserved

MASTITIS CASE MANAGEMENT

Interpretation of results from milk samples tested for mastitis bacteria with Mastit 4 qpcr test from DNA Diagnostic

Minna Koivula & Esa Mäntysaari, MTT Agrifood Research Finland, Animal Production Research, Jokioinen, Finland

Milk Secretion and Quality Standards

MSU Extension Publication Archive

Mastitis in Dairy. Cattle. Oregon State System of Higher Education Agricultural Experiment Station Oregon State College JOHN 0.

On- farm milk culture training workshop

Profitable Milk System

On-farm milk culture training workshop. Christina Petersson-Wolfe Department of Dairy Science Virginia Tech

Effect of omitting post-milking teat disinfection on the mastitis infection rate of dairy cows over a full lactation

Post Milking Teat Disinfection. Prevention of Contagious and Environmental Mastitis

F-MC-2: Dealing with Streptococcus agalactiae Mastitis

SUMMARY OF PRODUCT CHARACTERISTICS. Lincomycin (as Lincomycin hydrochloride) Neomycin (as Neomycin sulphate) Excipients Disodium edetate

Controlling Contagious Mastitis

Journal of Integrative Agriculture 2018, 17(6): Available online at ScienceDirect

Proper Dry Cow Management Critical for Mastitis Control

Best practice guide for on-farm mastitis control

Finnzymes Oy. PathoProof Mastitis PCR Assay. Real time PCR based mastitis testing in milk monitoring programs

Management Practices and Intramammary Infections: New Ideas for an Old Problem

The Uncommon. Bacillus cereus Clost. Perfringens Nocardia spp. Mycoplasma spp. Moulds and yeasts Pseudomonas spp.

DeLaval Cell Counter ICC User Strategies Guide

MILK QUALITY PROGRAMS FOR TRANSITION COWS AND HEIFERS. Leo Timms Iowa State University, Ames IA

10 Smart Things Dairy Farms Do To Achieve Milking Excellence

Food Assurance and Safety by John O Dwyer

Northern NY Agricultural Development Program 2016 Project Report

CoPulsation tm Milking System

Lactation. Macroscopic Anatomy of the Mammary Gland. Anatomy AS 1124

DAIRY HERD INFORMATION FORM

University of Missouri Extension Using the California Mastitis Test

Last 2-3 months of lactation

Prototheca Mastitis in Dairy Cows

Table 1. Adequacy of Recommended Milk Discard Times (Seymour et al., 1988)

Chemical and environmental treatment of whole. tree juniper chips to lower fecal coliform counts.

DAIRY VETERINARY NEWSLETTER

BIOSECURITY ON DAIRIES... ARE WE DOING ENOUGH?

USING MANURE SOLIDS AS BEDDING Final Report. CORNELL WASTE MANAGEMENT INSTITUTE Ithaca, NY

Goal 1: Harvest the Highest Quality Product

Udder Health and Milk Quality: from science to practice From Science to Practice Implementation of udder health PROFIT TEAMS

THIS ARTICLE IS SPONSORED BY THE MINNESOTA DAIRY HEALTH CONFERENCE.

April Boll Iowa State University. Leo L. Timms Iowa State University. Recommended Citation

Microbial Hazards in Dairy Industry Ceren Zeytinci

Mastitis Management and SCC Control in Once a Day Herds. Don Crowley- Teagasc

Dairy Calf, BVDv-PI Dead & Chronic Monitoring Program

Summary. Introduction. Damage Caused by Staphylococcus aureus Mastitis

Management Strategies to Reduce Heat Stress, Prevent Mastitis and Improve Milk Quality in Dairy Cows and Heifers

Improve performances in Dairy farms, an efficient and global hygiene method.

Veterinaria.com.pt 2009; Vol. 1 Nº 1: e13 (publicação inicial em Julho de 2008) Disponível em

Proper Dry-Off Procedures to Prevent New Infections and Cure Existing Cases of Mastitis. Stephen C. Nickerson University of Georgia

Options for Handling Mastitis during Lactation in Modern Dairy Farms

Mastitis: The Canadian Perspective

THE BOVINE MILK MICROBIOME. Mark McGuire

Selective Antibiotic Treatment for Dairy Cow Mastitis 1

Mastitis-Causing Streptococci Are Important Contributors to Bacterial Counts in Raw Bulk Tank Milk

Bovine Mastitis Products for Microbiological Analysis

Transcription:

LD 5/.,55 /J'l ~ :1. Virginia /)b.'/fll. i/os Cooperative ExteDSion Testing Bulk Tank Milk Samples G. M. Jones and Susan Sumner* Samples of bulk tank milk are collected regularly and milk quality tests are performed by milk coops, plants, or Virginia Department of Agriculture and Consumer Services. Some milk coops offer bulk tank profiles which involve several tests related to milk quality. The various tests are briefly described below, as well as a list of goals for high quality milk and conditions which adversely affect test results. Hopefully, an explanation of the use of these tests will help Virginia dairy farmers produce high quality milk, which has been defined by the Extension Milk Quality Leadership Council as milk with: Somatic cell count equal to or less than 200,000 Standard plate count equal to or less than 5,000 Preliminary incubation count equal to or less than 10,000 Drug residue free Sediment count equal to or less than 1.0 Cryoscope reading equal to or less than -.530 H Standard Plate Count (SPC) determines the number of visible colony-forming units (numbers of individual or tightly associated clumps of bacteria) in 1 ml. of milk incubated at 90 F for 48 hours. If SPC exceeds 5,000 cfu/ml., there is usually a reason. SPC is usually less than 5,000 cfu/ml. if sanitation is good and cooling is adequate. A SPC of 10,000 should be achievable by most farms (Murphy, 1997). The Extension Milk Quality Leadership Council has recommended that quality milk should have a SPC of 5,000 and less. In a test of 10,662 Virginia bulk tank samples by Virginia Department of Agriculture and Consumer Services (VDACS) between December 1, 1997, and November 16, 1998, 59% were below 5,000, 76% were below 10,000, and 87% were below 20,000. In New York State, of 855 bulk tank samples, 30% were below 5,400 cfu/ml and 50% were below 10,000 (Boor et al., 1998). The regulatory accepted limit is 100,000, although industry standards are often 50,000. Most high raw milk bacteria counts involve improper cleaning and sanitizing of dairy equipment, poor production practices (especially dirty cows), inadequate cooling, mastitis problems, or improper handling of sample by hauler or carrier of sample from plant to lab. Preliminary Incubation Count (PI Count)- A milk sample is incubated at 55 F for 18 hours, followed by the SPC procedure. PI~ount is considered the best measure of raw milk keeping quality and sanitation practices on farms. These organisms are usually associated with off-flavors, milk spoiling, and short shelf-life (Dairy Practices Council). PI Count should not exceed 100,000 cfu/ml. Desirable PICount is less than 25,000 cfu/ml. The Extension Milk Quality Leadership Council has recommended that quality milk should have a PICount of 10,000 and less. Of 855 bulk tanks tested in New York, only 30% were less than 26,000 and 10% were below 8,000 cfu/ml. VDACS does Professor of Dairy Science and Extension Dairy Scientist, Milk Quality & Milking Management; Associate Professor of Food Science & Technology and Extension Food Scientist, Microbiology, Virginia Tech, Blacksburg. Virginia flltech VIRGINIA POLYTECHNIC INSTITUTE AND STATE UNIVERSITY Virginia Cooperative Extension programs and employment are open to all. regardless of race, color, reli gion. sex, age, veteran status, national ori gin, disability, or political affil iation. An equal opportunity/affirmati ve acti on employer. Issued in fu rtherance o f Cooperati ve Extension work, Virgi nia Polytechnic Institute and State University, Vi rginia State University, and the U.S. Department of Agri culture cooperating. J. David Barrett, Interim Director. Virgi ni a Cooperati ve Ex tension, Virgini a Tech. Bl acksburg; Lorenza W. Lyons. Admini strator, 1890 Extensio n Program, Virg ini a State, Petersburg. VT/028/0299/ 1 M/992720/404405 VIRGINIA STATE UNIVERSITY

not conduct PI Counts but several milk coops do and use them in their quality premium payment programs. Listed below are possible causes of high PI Counts. These also could apply to high SPC. Failure to thoroughly clean equipment after each use or neglecting to sanitize equipment before using (a major cause) Slow cooling farm bulk tank or temperature above 40 F (bulk tanks should be less than 40 F within two hours of milking and kept below 45 F during subsequent milkings). This points out the importance of the recording thermometer and its use. Problems with debris buildup in plate coolers and chillers. When milking fresh cows and problem cows in bucket milkers, hoses need to be kept clean Dirty animals; may need clipping Poor udder sanitation practices (dirty, excessive water used to wash teats & udders); teats need to be clean, sanitized, and dry Contaminated water supply, especially coliforms or other spoilage-causing bacteria Wash water temperature should start at 155-1700F and drain at above 120 F Gaskets and rubber parts need to be clean, free of cracks and deposits, and replaced when necessary Improperly drained milking equipment Teatcup liners should be clean and free of cracks and changed on schedule Pulsator and main vacuum supply lines need cleaning on a regular basis and especially whenever milk enters the line Lab Pasteurized Count (LPC) measures the number of bacteria that survive lab pasteurization at 145 F for 30 minutes. Levels in raw milk should be less than 250-300 cfu/ml. Bacteria may be Bacillus species; usually it does not include mastitis-causing bacteria. Of 855 bulk tank samples analyzed in New York State, 60% were below 200 and 70% were less than 300 cfm/ml. These thermoduric (heat loving) bacteria may cause spoilage in pasteurized milk. High LPC can be caused by unclean equipment and/or improper sanitizing practices, as well as leaky pumps, old pipeline gaskets, inflations and other rubber parts, and milkstone deposits (Murphy, 1997). VDACS does not perform this test. Some milk coops include LPC as a part of the bulk tank profile. Coliform Count provides an indication of unsanitary production practices and/or mastitis infection. A count of less than 100 cfu/ml. is considered acceptable. Counts of 10 cfu/ml. or less are achievable and desirable. Of the NY bulk tank samples, 10% were less than 10 and 70% were below 66 cfu/ml. Udders and teats may be dirty and premilking hygiene may be inadequate. This test is not a part of VDACS' regulatory testing program. Contamination from the exterior of the udder can influence LPCs, PI Counts, and coliform counts (Murphy, 1997). The degree of cleanliness of the milking system probably influences the total bulk milk bacteria as much as, if not more, than any other factor. Milk residue left on equipment contact surfaces supports the growth of a variety of microorganisms. Environmental contaminants (i.e. from bedding, manure, feeds) are more likely to grow on soiled equipment surfaces. Less efficient cleaning, using lower temperatures and/or the absence of sanitizers tends to select for the faster growing, less resistant organisms, principally Gram-negative rods ( coliforms and Pseudomonads) and lactic streptococci. This will result in high PICounts and in some cases elevated LPCs. Streptococcus agalactiae or environmental streptococcus mastitis infections

Cryoscope or Freezing Point- Over -.530 Horvet suggests milk contains some added water or composition has been altered somehow. In New York, less than 3% of bulk tanks had freezing points greater than -.530. From December, 1997, through May, 1998, VDACS found only 16 violative samples in 5,631 tests or 0.28%. Possible causes of high cryoscope readings include: Intentional or accidental addition of water Chasing milk from receiver jar should not exceed 1.0. This test is conducted by some processors, but it's not done by all milk coops. Possible causes of high ADV: Violent agitation, such as excessive pumping, or excessive agitation caused by slow cooling in farm bulk tank, pipeline obstructions, or freezing in bulk tank The elimination of risers in milk lines and the use of vacuum tanks have removed some of this problem. Airleaks in pipelines Leaky valves Poor milking system drainage Flooded milklines, high milklines "Wet cow" milking or use of excessive water Backflushing units with vacuum on Bulk tank valve should be open to drain Rinsing top of tank Faulty gaskets in plate coolers (some brands) Freezing of milk in bulk tank Thin or under-conditioned cows because of grazing or low concentrate or energy intakes Sediment- Acceptable levels are less than 1.5 mg./ gal. milk. Cows' udders should be clipped, teats and udders need to be clean, and teatcups properly attached and removed. Large herds need to stop during milking and change filters. Although this test isn't conducted by VDACS nor by all milk coops, the Extension Milk Quality Leadership Council recommends that high quality milk should contain 1.0 or less. Rancidity causes objectionable flavor with sharp, unclean, astringent taste that lingers as an unpleasant aftertaste. Psychrotrophic organisms such as Pseudomonas, Aerobacter, and Bacillus are harbored in crevices of pipelines, gaskets, etc., as a result of poor cleaning and incomplete sanitation, and they produce lipases which may not be destroyed by pasteurization. Lipases hydrolyze (break down) fats to glycerol and free fatty acids. It is expressed as acid degree value (ADV) which Teatcup liner slippage or excessive air admission Late stage of lactation weakens fat globule membrane's protective lecithin-protein layer Milk Cultures- Culturing of bulk tank milk samples can be useful to determine the presence or absence of certain bacteria and may be conducted by milk plants, VDACS, veterinary services, or the Virginia-Maryland Regional College of Veterinary Medicine. Changes in bulk tank cultures will monitor the impact of management changes upon milk quality and infection status. Samples taken over consecutive days or weeks give a clearer picture of a herd's problem than a sample from one bulk tank of milk. Agitate the milk in the tank for 5 minutes prior to collection (National Mastitis Council or NMC). Use a clean, sanitized dipper to collect the milk sample from the top of the tank (never the outlet). Pour the first sample back into the tank to rinse sanitizer off the dipper. Sample two consecutive bulk tanks and freeze the samples. Sample the third bulk tank load and refrigerate it until all three samples can be delivered to a laboratory. The presence of Staphylococcus au reus or Streptococcus agalactiae almost always indicates the presence of these kind of mastitis infections in the herd. Staphylococcus aureus is shed in low numbers by infected quarters and generally does not cause high bacteria counts (SPC) in bulk tank milk, but bulk tank somatic cell count (SCC) would be expected to be elevated. NMC states that it should be possible to attain a bulk tank Staphylococcus aureus count of less than 50 cfm/ml.

The presence of Streptococcus agalactiae in bulk tank milk is due only to infected udders. Both bacteria count (SPC) and SCC could be elevated by the presence of this infection in the herd. Eradication of this pathogen from the herd is possible. Environmental streptococci and coliform (usually E. coli) counts above 1,000 and 500 cfm/ ml., respectively, indicate poor hygiene either during equipment cleaning and sanitation, during milking, or between milkings. Common contaminants are bedding, manure, soil, or water. According to NMC, milking wet udders, organic soil buildup in milklines, cracked gaskets and inflations, inadequately heated wash water, inadequate cooling of milk, and udder infections all contribute to high environmental streptococcal or coliform counts in bulk milk. Udder infections should be highly correlated to cases of clinical mastitis in the herd. Bacteria counts (SPC) may be high while sec are low. Once results of bulk tank cultures are known, milk samples should be collected from individual cows and cultured. Take aseptic samples from cows with high DHI SCC or positive CMT, cows with clinical mastitis, and fresh cows, especially heifers. Samples can be stored in the freezer for as long as 6 weeks. Individual cow sampling can sometimes be disappointing because no growth can occur with milk from problem cows. According to the NMC (1987), 25-40 percent of all clinical samples can be negative on routine culturing. The reasons include: : Numbers of certain organisms, such as mycoplasma, Staphylococcus aureus, and coliforms, can vary greatly in infected quarters, and may occasionally be less than the minimum detection limit of the assay. The minimum detection limit when plating 0.01 ml of milk is about 100 colony forming units per ml. : The organism may no longer be present and the clinical signs are due to by-products such as endotoxins. : Somatic cells may have phagocytized the organisms. : Antibiotics may have killed or suppressed organism numbers to unrecoverable levels. : Storage may have reduced numbers of viable organisms to undetectable levels. : The organism may require cultural conditions other than those used for isolation (i.e. reduced temperature, prolonged incubation, special media, anaerobic conditions, etc.). Three bulk tank samples were collected from a herd where the DHI SCC score averaged 3.36, with an actual sec average of537,000 and 28% of the cows had high sec (score 5 and above or actual sec above 284,000). The herd was treating 1-2 cows per week for clinical mastitis. At the previous month's test, the average sec score was 3.12, or actual sec averaged 477,000 and 20% of cows had high SCC. This suggests that the herd's subclinical mastitis is increasing. The bulk tank cultures had low coliform and streptococci counts accompanied by low bacteria counts. Two bulk tank samples had Staphylococcus aureus counts higher than desired. Staph infected herds often have high SCC but low bacteria counts. The dairy producer felt that the herd had symptoms characteristic of a herd with Staph infections. However, if bulk tank sample C had been the only sample collected, results would have been inconclusive and perhaps misleading. Bulk tank Streptococci Coliform perml perml Desired < 1,000 <500 A 320 340 B 840 40 c 760 0 Staohy_lococcus aureus perml Bacteria count perml <50 < 5,000 80 740 120 1,000 40 800

Microorganisms Found in Bulk Tank and Individual Cow Milk Samples Type of Bacteria Source Comments High High sec SPC Staph. aureus Infected quarters, Contagious: hands, wash ** (coagulase positive) Teat lesions, new rags, teatcup liners additions to herd Staph species Normal on teat Dry treat all cows, predip (coagulase neg.) skin, bedding, low & postdip with germicidal sec teat dip Str. agalactiae Infected quarters, Contagious: hands, wash ** ** new additions rags, teatcup liners to herd Environmental Manure, bedding, Wet & dirty conditions * ** streptococci wet & dirty teats, that expose teat ends to (non-agalactiae, liner slips bacteria; dirty housing Str. uberis or Str. and calving environments dysgalactiae) Coliforms (E. coli, Manure, bedding, Clipped, clean, and dry * * Klebsiella) wet & dirty teats udders & teats; freestalls Mycoplasma Infected quarters, Contagious: hands, wash ** new additions to rags, teatcup liners herd Pseudomonas Water, soil, Found in dirty milking manure equipment, contaminated water, contaminated antibiotics Proto theca Water, manure, No treatment; eliminate infected quarters stagnant water & manure Serratia Contaminated Eliminate washing of water, bedding or udders & teats litter Nocardia Infected quarters, Found in contaminated treatments & multi-dose Yeast & molds Infected quarters Found in contaminated treatments & multi-dose

References: Boor, K.J., D.P. Brown, S.C. Murphy, S.M. Kozlowski, and D.K. Bandler. 1998. Microbial and chemical quality of raw milk in New York State. J. Dairy Sci. 81:1743-1748. Dairy Practices Council. 1991. Guidelines for raw milk quality tests, Publication DPC 21, Barre, VT. Dairy Practices Council. 1997. Guidelines for troubleshooting on-farm bacteria counts in raw milk, Publication 24, Barre, VT. National Mastitis Council. Using Bulk Tank Milk Cultures in a Dairy Practice. http:// www.nmconline.org/bulktank.htm. National Mastitis Council. 1987. Laboratory and Field Handbook on Bovine Mastitis, Madison, WI. Reinemann, D.J., G.A. Mein, D.R. Bray, D. Reid, and J.S. Britt. 1997. Troubleshooting high bacteria counts in farm milk. p. 65-79 in Proc. 36th Annual Meeting of National Mastitis Council, Madison, WI. Murphy, S.C. 1997. Raw milk bacteria tests: Standard plate count, preliminary incubation count, lab pasteurization count and coliform count- What do they mean for your farm? page 34-42 in Proc. National Mastitis Council Regional Meeting, Syracuse, NY.