COOPER POWER SERIES. S.T.A.R. Type ER faulted circuit indicator installation instructions. Fault Indicators MN320006EN

Similar documents
COOPER POWER SERIES. S.T.A.R. PATHFINDER variable trip TPR faulted circuit indicator installation instructions. Fault indicators MN320003EN

S Fault Indicators. S.T.A.R. Type CR Faulted Circuit Indicator Installation Instructions. Contents PRODUCT INFORMATION

Outdoor Bark Control

Elite Outdoor Bark Control

SAFETY BURNDY HYPRESS TM OPERATING & MAINTENANCE INSTRUCTIONS Y750BH 2004 FCI USA INC.

Operating Guide. PBC Rechargeable Bark Control Collar. Please read this entire guide before beginning.

Vibratory Tumbler OWNER S MANUAL

FCI LT LM UNDERGROUND

Product Manual. PBC Bark Collar. Please read this entire Product Manual before beginning.

300 Yard Trainer GDT Product Manual

400 Yard Trainer GDT Product Manual

IEEE Std 592 Test Program using Current Cable Accessories and Installation Practices

NoBark 6. Operating Guide. Please read this entire guide before beginning

INNOTEK. Spray Bark Control. Operating Guide. Please read this entire guide before beginning.

FAQ (Frequently Asked Questions)

Puppy Sales Contract

OPERATING AND BASIC TRAINING GUIDE PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING

Delta Smart. Owner s Manual

Table of Contents Operating Guide Training Guide

Laurelview Dog Kennel

advanced bark control collar INSTRUCTION Manual

Part Number: CAT6+ UTP PVC PATCH CORDS CAT6+ Patch Cord, UTP, PVC

SMARTKITTY SELFCLEANING LITTER BOX

advanced remote trainer INSTRUCTION Manual

Basic Bark Control Collar

Elite Bark Control PBC operating and training guide. Big Dog Model Number. Little Dog Model Number

PetSpy Premium Dog Training Collar, Models M919-1/M919-2

3M Industrial Tapes for Marking. Delivering the durability you need and the versatility you want.

Model Number HBK '(W) x 5'(L) x 5'(H) laurelview. dog kennel assembly instructions. Please read this entire guide before assembly

BARK CONTROL COLLAR Model NB-Pulse. User s guide

Product Manual 100, 300, 600 AND 900 YARD REMOTE TRAINERS LITE STANDARD ADD-A-DOG

Trigger Spray CAUTION

PetSpy Advanced Dog Training System, Model M86N

EPA Est. No IL-001. Assurity and Elanco. EPA Reg. No

PetSafe Big Dog Spray Bark Control Collar

Part Number: CAT6+ UTP PVC PATCH CORDS CAT6+ Patch Cord, UTP, PVC

Product Manual. ZAL Simply Clean Automatic Litter Box. Please read this entire Product Manual before beginning.

YEAR FOR MULTI-CAT HOUSEHOLDS. CustomerCare Line: LM580 LM680C LM980. AUTOMATIC Self-Cleaning Litter Box. USA/Canada , Option 1

Product Manual. PDT Remote Spray Trainer. Please read this entire Product Manual before beginning.

Your American Made Source

4MONTHS FORDOGS MEDIUM DOG WARNING MEDIUM DOG LBS REPELS AND KILLS TICKS, FLEAS, & MOSOUITOS

PetSafe Deluxe Bark Control

Ultrasonic Bark Control Collar

Woonsocket Education Department REQUEST FOR PROPOSAL. For. Copiers Multi Function Device Lease

QUICK-ACTING LONG-LASTING WATERPROOF READ ENTIRE LABEL AND ENCLOSED DIRECTIONS BEFORE EACH USE

FOR MULTI-CAT HOUSEHOLDS

Pixie-7P. Battery Connector Pixie-7P Fuse* Motor. 2.2 Attaching the Motor Leads. 1.0 Features of the Pixie-7P: Pixie-7P Batt Motor

WARNING KEEP OUT OF REACH OF CHILDREN DO NOT USE ON CATS. Code: pvasmmd

Lioness Guidebook: Open Me to Get Started!

DURA PLASTIC PRODUCTS, INC.

ultrasmart receiver collar

Programming and Installation Guide. PPA Microchip Cat Flap. Series. Please read this entire guide before beginning.

Delta Upland Owner s Manual

Elite Big Dog Spray Bark Control

By Dogtra Remote Controlled Dog Training Collars. Owner's Manual. Please read this manual thoroughly before operating the Dogtra ARC training collar.

SUPER TRAINER EZT SERIES

7300 SPT 7302 SPT 7800 SPT 7802 D.T. SYSTEMS, INC.

OPERATING GUIDE PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING

Adoption Application/Contract

Remote Trainer. by Dogtra Portable Remote Controlled Dog Training Collars. Owner s Manual

Installation Instructions

Smart bark control collar BC-2. User manual

By Dogtra Remote Controlled Dog Training Collars. Owner's Manual. Please read this manual thoroughly before operating the Dogtra EDGE training collar.

LP-NSM(L) Series. Features. Product Dimensions. Small size of Fast tripping resettable circuit protection

INTRODUCTION PRODUCT FEATURES. Congratulations on your purchase of the Yapper Stopper Model YS500.

Elite Little Dog Spray Bark Control

R&J Enterprises Green Cove Springs, FL Rjaquatics.com

Ohio Valley Labradoodles Ltd.

HOME N GO PET PEN PG4200/PG4400

USA Product Label PARASTAR PLUS (45-88 LBS.) Novartis. (fipronil/cyphenothrin) 3 EASY-TO-USE APPLICATIONS. For dogs lbs.

Owner s Manual. by Dogtra Portable Remote Controlled Dog Training Collars

ANIMAL SERVICES AGREEMENT

by Dogtra Portable Remote Controlled Dog Training Collars Owner s Manual

Dances With Wolves Ranch, LLC Puppy Purchase Agreement and Limited Warranty

S-Methoprene 1.2% CAUTION. IGR Concentrate. EPA Est. No. indicated by last

Single Port Modular Jacks

Sold by:

LP-NSM(L) Series. Features. Product Dimensions. Small size of Fast tripping resettable circuit protection

CONTRACT & HEALTH WARRANTY PET DOG

Express Train Electronic Radio Dog Training Collar

-1- Please refer to the SAFETY INSTRUCTIONS portion of this manual

All rights reserved. Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of Garmin.

adult fleas flea eggs flea larvae adult ticks tick nymphs tick larvae KILLS & REPELS: mosquitoes KEEP OUT OF REACH OF CHILDREN CAUTION

ULTRA CLEAR SW AQUARIUM

Getting Started. Device Overviews. Setting Up the Pro 550 System Before you can use the Pro 550 system, you must set up the devices.

Our K9 LLC 616 Corporate Way Valley Cottage New York GARNET STATIC SHOCK BARK COLLAR USERS GUIDE

Owner's Guide. ProFence

GARNET STATIC SHOCK BARK COLLAR

Pet-Temp PT-300 Ear Thermometer Frequently Asked Questions

Demi s Animal Rescue, Inc. Terms of Adoption (Dog) Animal s Name: Breed: Sex: Weight: Age: Microchip ID: Notes:

GARNET STATIC SHOCK BARK COLLAR

Table Of Contents. Important Safeguards...2. PT4 Transmitter Features...3. R7 and R9 Receiver Collar Features...5

Keep Out Of Reach Of Children

By Dogtra Remote Controlled Dog Training Collars. Owner's Manual. Please read this manual thoroughly before operating the Dogtra 280C training collar.

User s Guide. High Performance Linear Products SLOU119

Current shot records for the aforementioned canine are attached as Exhibit A and made a part of this contract.

Quick Start ,3 Trouble Shooting ,5 Training

Operating and Training Guide

YELLOW VIBRATION BARK COLLAR

AT-215. Owner's Manual

Transcription:

Fault Indicators MN320006EN Effective March 2017 Supersedes August 2008 (S320-60-1) COOPER POWER S.T.A.R. Type ER faulted circuit indicator installation instructions SERIES

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. i

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY... i Safety for life... iii Safety information... iii Safety instructions... iii Product information.... 1 Installation procedure.... 2 Operation instructions.... 3 ii

! SAFETY FOR LIFE Safety for life Eaton s Cooper Power series products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high-voltage lines and equipment and support our Safety For Life mission.! SAFETY FOR LIFE Safety information The instructions in this manual are not intended as a sub stitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians, who are familiar with this equipment should install, operate and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as flash clothing, safety glasses, face shield, hard hat, rubber gloves, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result In death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with high voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment. Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply may result in death, severe personal injury and equipment damage. Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install, or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. iii

S.T.A.R. Type ER faulted circuit indicator installation instructions Product information Introduction The Eaton Cooper Power series S.T.A.R. Electrostatic Reset (ER) Faulted Circuit Indicators are used primarily on overhead conductors and indicate the passage of fault current by showing a fault flag in the Fisheye display window. When the fault is cleared from the system and the line is re-energized, the fault indicator will automatically reset. A minimum of 6.9 kv line-to-ground is needed in order to reset the fault indicator. The Eaton Cooper Power series S.T.A.R. Faulted Circuit Indicator (FCI) is weatherproof, submersible and meets or exceeds IEEE Std 495-1986 standard IEEE Guide for Testing Faulted Circuit Indicators. The Fisheye target display will not change status due to mechanical shock or vibration. The S.T.A.R. ER Faulted Circuit Indicator clamps easily to the overhead conductor by using a standard clamp (shotgun) stick. It is primarily for use on uninsulated, unshielded cable, but may also be used on insulated unshielded cable such as tree wire. The fault indicator clamping mechanism will allow the indicator to be used on cable sizes from 0.25 (6.4 mm) up to 2.0 (51 mm) in diameter. The FCI is available with either a high (HI) or low (LO) trip level. A low trip level will activate at approximately 400 A on a 1.2 diameter cable and the high trip operates at approximately 900 A on the same cable size. The trip rating will vary slightly for other cable dimensions. Refer to Figure 2 for trip levels on other cable diameters. Trip Rating A (rms) 1200 1100 1000 900 800 700 600 500 400 300 200 0.2 (5.1) 0.4 (10.2) 0.6 (15.2) 0.8 (20.3) 1.0 (25.4) Cable Diameter at Installation in Inches (mm) 1.2 (30.5) High Trip Level Low Trip Level 1.4 (35.6) 1.6 (40.6) Figure 2. S.T.A.R. Type ER faulted circuit indicator cable diameter vs. Trip value curves Read this manual first Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment. Additional information These instructions cannot cover all details or variations in the equipment, procedures, or process described nor provide directions for meeting every possible contingency during installation, operation, or maintenance. For additional information, contact your representative. Acceptance and initial inspection Each faulted circuit indicator is in good condition when accepted by the carrier for shipment. Upon receipt, inspect the shipping container for signs of damage. Unpack the faulted circuit indicator and inspect it thoroughly for damage incurred during shipment. If damage is discovered, file a claim with the carrier immediately. Handling and storage Be careful during handling and storage of the faulted circuit indicator to minimize the possibility of damage. If the faulted circuit indicator is to be stored for any length of time prior to installation, provide a clean, dry storage area. Standards ISO 9001 Certified Quality Management System Figure 1. S.T.A.R. Type ER faulted circuit indicator 1

S.T.A.R. Type ER faulted circuit indicator installation instructions Installation procedure 1. Arm the FCI clamp mechanism by grasping each clamping arm (Figure 3), pulling them apart until the trigger arm latches into place. Stops have been built into the clamping arms such that they will only open to the point where the trigger arm will latch (Figure 4). 2. Attach the FCI to a clamp (shotgun) stick using the pulling eye on the front of the faulted circuit indicator. At 6.9 kv, the S.T.A.R. ER Type Fault Circuit Indicator should be installed no more than five feet from a ground plane. 3. Push the FCI clamping mechanism against the conductor until the trigger mechanism releases from the latched position. Remove the clamp stick. For cable diameters from 0.25 (6.4 mm) to 1.0 (25 mm), the clamp arm pads are required to properly clamp onto the conductor. For cable diameters from 1.0 up to 2.0 (51 mm), the clamp arm pads are not needed and should be removed. The S.T.A.R. ER Type Faulted Circuit Indicator is shipped to the customer in the tripped position. When properly installed, the FCI will reset in approximately 8 minutes on a 6.9 kv lineto-ground system. The FCI reset time may vary depending on the system voltage and distance to the nearest ground plane. Refer to Table 1 for nominal reset times. Table 1. Ground plane vs. Reset time Reset time (minutes) Fci distance to ground plane Voltage (kv) line-to- ground 36 Inches 6.9-8 8 8-26 6 >26 <4 5.06 (128.5 mm) Clamp arms 5.7 (144 mm) 3.66 (93.0 mm) Figure 4. Type ER faulted circuit indicator with clamp in armed position Latch mechanism Care should be used when installing the FCI on a de-energized system without the use of a shotgun stick. When the clamping mechanism closes, the trigger arm swiftly swings toward the pulling eye and injury could occur if fingers or hands are in the trigger arm s path. Removing the FCI 1. Insert the hook end from the shotgun stick into the pulling eye of the FCI and lock the shotgun stick tight against the FCI body. 2. Pull straight back on the hotstick. For quicker/simpler removal of the FCI, it can be removed with hot-line gloves. 3. If the clamp pads are to be used with the FCI upon re-installation, ensure that the pads are properly attached to the clamp arms. Trigger arm Figure 3. Type ER faulted circuit indicator with clamp in unarmed position 2

S.T.A.R. Type ER faulted circuit indicator installation instructions Operation instructions The S.T.A.R. Type ER Fault Indicator utilizes the FISHEYE display and will rotate the ball from black to orange to indicate sensing a fault. The ball will remain in the orange position indefinitely until the system is restored and a minimum of 6.9 kv is present. If the FCI is equipped with the optional LED indicator, both the FISHEYE as well as the LED will sense the restoration of voltage and will reset the FISHEYE back to the black position and turn off the LED. Note: the LED equipped FCI will blink for a maximum 4 hours per fault event. The FCI will sense the loss of 60 Hz pulses and will disable the tripping circuitry following the loss of power. This is done to prevent false tripping on Reclosure operations. The LED version is equipped with a non-replaceable battery, which is used only to provide power for the LED indicator. If the battery fails the FCI will still function and the FISHEYE display will continue to operate. 3

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No. MN320006EN Rev 0 Supersedes S320601 Rev 2 March 2017 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.