Ensure you have the right acute CVC for any treatment and every patient.

Similar documents
PROCESS SPECTRUM CATHETERS

RADIAL APPROACH ACCESSORIES Rad Board Radial Arm Board 3 Rad Board Accessories 3-4 Rad Board Xtra 3 Rad Trac 4 Rad Rest 4

Management of CRBSI Leilani Paitoonpong MD MSc Chusana Suankratay MD PhD Division of Infectious Diseases Chulalongkorn University

Kit-Construction block

Interrupting The ECMO Circuit

MEDICATION ADMINSITRATION: ANTIBIOTIC LOCK THERAPY GUIDELINE

St George/Sutherland Hospitals And Health Services (SGSHHS)

REVISIONE CRITICA sulla VALIDITA delle COMUNI MISURE per la PREVENZIONE delle INFEZIONI CORRELATE a CATETERE INTRAVASCOLARE

GASTRO-INTESTINAL (ENTERAL)

GASTRO-INTESTINAL (ENTERAL)

No-leaching. No-resistance. No-toxicity. >99.999% Introducing BIOGUARD. Best-in-class dressings for your infection control program

Antimicrobial Stewardship. We cannot afford to go back

11/10/2011 Revised_ver.2.0 Improved Antibiotic Impregnated Catheters with Extended Spectrum Activity Against Resistant Bacteria and Fungi

Regional and Local Anesthesia of the Wrist and Hand Aided by a Forearm Sterile Elastic Exsanguination Tourniquet - A Review

APIC CHAPTER PRESENTATION 7/2014

Does Screening for MRSA Colonization Have A Role In Healthcare-Associated Infection Prevention Programs?

Antimicrobial Stewardship

Healthcare-associated Infections and Antimicrobial Use Prevalence Survey

Legend. Reusable. Rotatable. Disposable. Thickness in released position. Internal diameter in released position. Cup opening.

Surgical Solutions Product Catalogue DEPEND ON HALYARD'S EXPERTISE TO HELP PREVENT INFECTIONS IN THE OR

Using Web-Based Instruction Modules to Improve Practitioner Knowledge at Yale New Haven Hospital on the Prevention of Antimicrobial Resistance and

UPDATE ON ANTIMICROBIAL STEWARDSHIP REGULATIONS AND IMPLEMENTATION OF AN AMS PROGRAM

Carbapenemase-Producing Enterobacteriaceae (CPE)

NHSN 2015 Rebaseline and TDH Updates. Ashley Fell, MPH

Model Infection Control Plan for Veterinary Practices, 2010

Perioperative Infection. Surgical site infections: How to prevent them. Surgical site infections

So Why All the Fuss About Hand Hygiene?

Antibiotic Line Lock Guideline

ASCENSION TEXAS Antimicrobial Stewardship: Practical Implementation Strategies

4-H CVA LEVEL I EXAM APPLICATION PLEASE PRINT. First Name: Last Name: Address: City State Postal Code: Phone:( ) Date of Application:

MDRO in LTCF: Forming Networks to Control the Problem

HOSPITAL-ACQUIRED INFECTION/MRSA EYERUSALEM KIFLE AND GIFT IMUETINYAN OMOBOGBE PNURSS15

Model Infection Control Plan for Veterinary Practices, 2015


Laparoscopic Bariatric Instruments

MEDICAL DEVICES. 1 Infusion Set Tube latex. Micro Infusion Set Built In Airvent. 2 Micro Infusion Set Tube latex

Infection Prevention Highlights for the Medical Staff. Pamela Rohrbach MSN, RN, CIC Director of Infection Prevention

MICROCHIP IMPLANTATION

SOP: Blood Collection in the Horse

State of Nevada Board of Veterinary Medical Examiners Hospital Inspection Checklist

Hand washing/hand hygiene reduces the number of microorganisms on the hands and is the most important practice to prevent the spread of infection.

Antimicrobial Selection and Therapy for Equine Musculoskeletal Trauma

Features & Benefits WITHOUT VENT PLUG/ RED CAP WITH VENTED WITH VENT PLUG. 20 Fr 33cm A2016 A2016V 24 cm B2016 B2016V

Implementing Antibiotic Stewardship in Rural and Critical Access Hospitals

Dr Eleri Davies. Consultant Microbiologist and Infection Control Doctor, Public Health Wales NHS Trust

Antibiotic Stewardship: A National Call to Action. Deborah A Pasko, Pharm.D, MHA THA November 17, 2016

DATA COLLECTION SECTION BY FRONTLINE TEAM. Patient Identifier/ Medical Record number (for facility use only)

Infection Prevention and the Buttonhole Technique? Lynda K. Ball, MSN, RN, CNN

Optimizing Antimicrobial Stewardship Activities Based on Institutional Resources

WENDY WILLIAMS, MT(AMT) MSAH DIRECTOR LABORATORY AND PATHOLOGY SERVICES. Appalachian Regional Healthcare System apprhs.org

Hospital Infection. Mongolia, October Walter Popp Hospital Hygiene University Clinics Essen, Germany

Assuring Quality: A guide for youth livestock producers Activity for 2008

Challenges and opportunities for rapidly advancing reporting and improving inpatient antibiotic use in the U.S.

The only device incorporating infrarenal anchors for active fixation with proven migration prevention through 5 years of follow-up.

CLINICAL ESSENTIAL HUDDLE CARD. All associates must comply with their state practice acts.

EASTER BUSH PATHOLOGY, R(D)SVS POST MORTEM ROOM CODE OF PRACTICE CONTENTS

LATARJET Open Surgical technique

INSTRUCTIONS FOR USE FOR:

Clostridium Difficile Primer: Disease, Risk, & Mitigation

Poultry Watering Systems Catalogue

Nosocomial Infections. David M. Parenti, M.D.

EASTER BUSH PATHOLOGY, R(D)SVS POST MORTEM ROOM CODE OF PRACTICE CONTENTS

7/25/2014. Proper Injection Technique. Review Pork Quality Assurance Plus. Contact Information. Why are injections given?

Hot Topics in Antimicrobial Stewardship. Meghan Brett, MD Medical Director, Antimicrobial Stewardship University of New Mexico Hospital

Antibiotic Treatment of Peritonitis

Preventing Multi-Drug Resistant Organism (MDRO) Infections. For National Patient Safety Goal

In-Service Training Program. Managing Drug-Resistant Organisms in Long-Term Care

Preventing and Responding to Antibiotic Resistant Infections in New Hampshire

Updates in Antimicrobial Stewardship

MHA/OHA HIIN Antibiotic Stewardship/MDRO Collaborative

Accidental Exposure to Cattle Brucellosis Vaccines in Wyoming, Montana, and Idaho Veterinarians

TITLE 10 EQUINE MOBILE

SINGLE ANNUAL IMPLANT

MDRO: Prevention in 7 Steps. Jeanette Harris MS, MSM, MT(ASCP), CIC MultiCare Health System Tacoma, Wa.

Hospital Acquired Infections in the Era of Antimicrobial Resistance

STRANDS AND STANDARDS

Blood Collection Healthcare

General Surgery Small Group Activity (Facilitator Notes) Curriculum for Antimicrobial Stewardship

IT Clamp 50. Transforming the Field of Emergency Trauma Care

11/22/2016. Hospital-acquired Infections Update Disclosures. Outline. No conflicts of interest to disclose. Hot topics:

Antimicrobial Stewardship Programs The Same, but Different. Sara Nausheen, MD Kevin Kern, PharmD

HALE SECURITY PET DOOR CAT GUARDIAN patent pending

Public Health Response to Emerging Resistance

Geriatric Mental Health Partnership

Antibiotic Stewardship in Human Health- Progress and Opportunities

Poultry Watering Systems Catalogue

11/22/2016. Antimicrobial Stewardship Update Disclosures. Outline. No conflicts of interest to disclose

Antimicrobial Stewardship in the Hospital Setting

Infection Prevention & Control in Ambulatory Surgical Centers. Objectives

SOS EMERGENCY ANIMALS Please note that the following scenario(s) are generalized

FM - Male, 38YO. MRSA nasal swab (+) Due to positive MRSA nasal swab test, patient will be continued on Vancomycin 1500mg IV q12 for MRSA treatment...

Methicillin-Resistant Staphylococcus aureus

Antimicrobial Stewardship:

General Show Rules. Points are awarded as follows: Place: 1st 2nd 3rd 4th 5th 6th 7th 8th 9th 10th

Surveillance of Multi-Drug Resistant Organisms

Giving IV Medication by Balloon System (EIS)

Antimicrobial Stewardship in the Outpatient Setting. ELAINE LADD, PHARMD, ABAAHP, FAARFM OCTOBER 28th, 2016

Commonwealth of Kentucky Antibiotic Stewardship Practice Assessment For Long-Term Care Facilities

Product catalogue 2015

In an effort to help reduce surgical site infections, Surgical Services associates will be expected to observe the following guidelines:

Transcription:

Ensure you have the right acute CVC for any treatment and every patient. Cook Spectrum ANTIMICROBIAL TECHNOLOGY 2, 3, and 5 lumens WITH HIGH FLOW RATES CENTRAL VENOUS CATHETERS POWER-INJECTABLE Maximal STERILE BARRIER trays MEDICAL

CONTENTS Contents information... 3 Component listing...4-5 COOK SPECTRUM TECHNOLOGY Cook Spectrum antimicrobial technology... 6 WITH MSB COMPONENTS Cook Spectrum CVC trays with maximal sterile barrier (MSB) components... 7 WITHOUT MSB COMPONENTS Cook Spectrum CVC trays without MSB components... 8 WITH STANDARD COMPONENTS Cook Spectrum CVC sets... 9-12 UNIMPREGNATED WITH MSB COMPONENTS Unimpregnated CVC trays with MSB components... 13 WITHOUT MSB COMPONENTS Unimpregnated CVC trays without MSB components... 14 WITH STANDARD COMPONENTS Unimpregnated CVC sets...15-18

MULTIPLE LUMEN OPTIONS WTH HIGH FLOW RATES Multiple lumen options with high flow rates Double lumen Distal Proximal Suggested use Whole blood or blood product delivery and sampling, any fluid requiring greater flow rate, central venous pressure (CVP) monitoring, medication delivery, power injection* Medication delivery, acute hyperalimentation Triple lumen/five lumen Distal Mid(s) Proximal(s) Suggested use Whole blood or blood product delivery and sampling, any fluid requiring greater flow rate, CVP monitoring, medication delivery, power injection* Medication delivery, acute hyperalimentation Medication delivery CT is printed on the distal lumen only. Power inject contrast media through the distal lumen on power-injectable CVCs only. Blood work and power injection should be done through the distal lumen, as it is larger and has a greater flow rate. Be sure to temporarily stop infusions and clamp the middle and proximal ports to avoid contamination of blood when drawing samples from the distal lumen. flow rates are printed on the lumen clamp. 3 *Power-injectable CVCs are available in 7, 8, 9, and 10.

COOK CATHETER TRAY AND FULL SPECTRUM TRAY WITH MAXIMAL STERILE BARRIERS Cook CVC set and tray options to support your procedures The CVC is designed for treatment of critically ill patients and is suggested for: 1. Continuous or intermittent drug infusions 2. CVP monitoring 3. Acute hyperalimentation 4. Blood sampling 5. Delivery of whole blood or blood products Sizes and configurations for every patient PREPARATION PLACEMENT POSTPROCEDURE Cook s bedside sets and trays provide a convenient assortment of the components needed to place a central venous catheter (CVC) at the bedside. The sets and trays are ergonomically designed and sequentially organized to promote procedural efficiency and accuracy. 6. Power injection of contrast media Tray solutions to help you comply with recommendations from 10 organizations. Cook Spectrum and unimpregnated CVC trays with MSB components, including a cap, mask, and gown, are specifically design to help your facility s goal of reaching an infection rate of zero. Both tray options are designed to help meet these organizations injury and infection prevention guidelines: Agency for Healthcare Research and Quality (AHRQ) Canadian Center for Occupational Health and Safety (CCOHS) Centers for Disease Control and Prevention (CDC) Canadian Patient Safety Institute (CPS) The Comprehensive Unit-Based Safety Program (CUSP) Infectious Diseases Society of America (IDSA) Institute for Healthcare Improvement (IHI) The Joint Commission Society for Healthcare Epidemiology of America (SHEA) Occupational Safety & Health Administration (OSHA) These organizations recommend MSB precautions or needlestick prevention to minimize injuries and reduce infections in both patients and clinicians. For complete information, please refer to the Instructions for Use that is included with each product. 4

COMPONENTS Cook Spectrum and unimpregnated CVC trays WITH MSB COMPONENTS Preparation Door stop sign insertion checklist Large fenestrated drape Sterile gown Mask with face shield Cap Placement Cook Spectrum or unimpregnated power-injectable* CVC Dilator(s) Wire guide and holder EchoTip echogenic needles Safety scalpel BakSnap safety syringe(s) 22 and 25 hypodermic needles holder cup Curved needle sutures driver Sterile gauze sponges 12 disposable syringe Transducer tubing MicroClave neutral displacement connectors CSR wrap Cook Spectrum and unimpregnated CVC trays WITHOUT MSB COMPONENTS Placement Cook Spectrum or unimpregnated power-injectable* CVC Dilator(s) Wire guide and holder EchoTip echogenic needles Safety scalpel BakSnap safety syringe(s) 22 and 25 hypodermic needles holder cup Curved needle sutures driver Sterile gauze sponges 12 disposable syringe Transducer tubing MicroClave neutral displacement connectors CSR wrap Postprocedure Locking sharps needle vise Moveable suture wing StatLock catheter securement device** Patient information card Cook Spectrum and unimpregnated CVC sets WITH STANDARD COMPONENTS Placement Cook Spectrum or unimpregnated power-injectable* CVC Dilator(s) Wire guide and holder EchoTip echogenic needles holder cup 6 disposable syringe MicroClave neutral displacement connectors CSR wrap Postprocedure Locking sharps needle vise Moveable suture wing StatLock catheter securement device** Patient information card 5 *Power-injectable CVCs are available in 7, 8, 9, and 10. **The StatLock securement device is only available with 4 and 5 CVCs. BakSnap is a registered trademark of DuoProSS Meditech Corp. MicroClave is a registered trademark of ICU Medical, Inc. StatLock is a registered trademark of C.R. Bard, Inc.

COOK SPECTRUM TECHNOLOGY Provide your patients with proven protection against CRBSIs. 1 We developed Cook Spectrum technology to help provide optimal patient care by decreasing hospitals rates of catheter-related bloodstream infections (CRBSIs). 1 The right combination Cook Spectrum catheters are impregnated with a combination of the antibiotics minocycline and rifampin in order to help patients by providing proven protection against CRBSIs. 1 Unmatched evidence The efficacy of Cook Spectrum is supported by more than 30 sources published over the past two decades, including peer-reviewed studies and meta-analyses. Cook SPECTRUM CATHETERS meet the CDC 1A RECOMMENDATION as a component of the prevention of CLABSIs. 2 No evidence of increased resistance More than 10 years of clinical use and a 7-year study of more than 500,000 Cook Spectrum catheter days have shown no evidence of increased antibiotic resistance. 2 Worth switching Switching from uncoated catheters to Cook Spectrum catheters helps provide quality patient care by decreasing the risk for CRBSIs and the costs associated with treating them. 1,3 1. Raad I, Darouiche R, Dupuis J, et al. Central venous catheters coated with minocycline and rifampin for the prevention of catheter-related colonization and bloodstream infections: a randomized, double-blind trial. Ann Intern Med. 1997;127(4):267-274. 2. O Grady N, Alexander M, Burns L, et al. Guidelines for the prevention of intravascular catheter-related infections, 2011. Centers for Disease Control and Prevention Web site. www.cdc.gov/infectioncontrol/ guidelines/pdf/bsi/bsi-guidelines-h.pdf. Updated October 2017. Accessed October 26, 2018. The 1A recommendation from the Centers for Disease Control and Prevention (CDC) guidelines for the prevention of intravascular catheter-related infections, 2011, is to use a chlorhexidine/silver sulfadiazine or minocycline/ rifampin -impregnated CVC in patients whose catheter is expected to remain in place >5 days if, after successful implementation of a comprehensive strategy to reduce rates of CLABSI, the CLABSI rate is not decreasing. SPECTRUM TECHNOLOGY PROCESS BUNDLE Learn more about Cook Spectrum technology, including links to a vast body of research investigating and supporting Cook Spectrum, at spectrum.cookmedical.com. 3. Zimlichman E, Henderson D, Tamir O, et al. Health care-associated infections: a meta-analysis of costs and financial impact on the US health care system. JAMA Intern Med. 2013;173(22):2039-2046. 6

COOK SPECTRUM CVC TRAYS WITH MSB COMPONENTS Cook Spectrum CVC trays WITH MSB COMPONENTS Part Cross-section s G44809 C-UTLMYJ-701J-ABRM-HC-IHI-FST-A-RD 3 7 15.032 60 18/5, 7 Distal 16.6 3,840 10 143.3 G44807 C-UTLMYJ-701J-RSC-ABRM-HC-IHI-FST-A-RD 3 7 20.032 60 18/5, 7 Distal 16.6 3,840 10 143.3 G44815 C-UTLMYJ-701J-LSC-ABRM-HC-IHI-FST-A-RD 3 7 25.032 60 18/5, 7 Distal 16.6 3,840 10 143.3 Mid 18.6 1,860 - - G44792 C-UDLMYJ-801J-ABRM-HC-IHI-FST-A 2 8 15.032 60 18/5, 7 Distal 14.9 6,780 10 55.1 G44794 C-UDLMYJ-801J-RSC-ABRM-HC-IHI-FST-A 2 8 20.032 60 18/5, 7 Distal 14.9 6,780 10 55.1 G44812 C-UTLMYJ-901J-ABRM-HC-IHI-FST-A-RD 3 9 15.032 60 18/5, 7 Distal 14.9 10,140 10 35.8 G44813 C-UTLMYJ-901J-RSC-ABRM-HC-IHI-FST-A-RD 3 9 20.032 60 18/5, 7 Distal 14.9 10,140 10 35.8 Proximal 18.5 1,440 - G44802 C-UQLMYJ-1001J-ABRM-HC-IHI-FST-A-RD 5 10 15.032 60 18/5, 7 Distal 14 1 8,820 10 32.1 G44801 C-UQLMYJ-1001J-RSC-ABRM-HC-IHI-FST-A-RD 5 10 20.032 60 18/5, 7 Distal 14 1 8,820 10 32.1 /sec Average Hub Pressure at Flow psi 7

COOK SPECTRUM CVC TRAYS WITHOUT MSB COMPONENTS Cook Spectrum CVC trays WITHOUT MSB COMPONENTS Part Cross-section s G44808 C-UTLMYJ-701J-ABRM-HC-FST-A-RD 3 7 15.032 60 18/5, 7 Distal 16.6 3,840 10 143.3 G44806 C-UTLMYJ-701J-RSC-ABRM-HC-FST-A-RD 3 7 20.032 60 18/5, 7 Distal 16.6 3,840 10 143.3 G44814 C-UTLMYJ-701J-LSC-ABRM-HC-FST-A-RD 3 7 25.032 60 18/5, 7 Distal 16.6 3,840 10 143.3 G44793 C-UDLMYJ-801J-ABRM-HC-FST-A 2 8 15.032 60 18/5, 7 Distal 14.9 6,780 10 55.1 G44795 C-UDLMYJ-801J-RSC-ABRM-HC-FST-A 2 8 20.032 60 18/5, 7 Distal 14.9 6,780 10 55.1 G44811 C-UTLMYJ-901J-ABRM-HC-FST-A-RD 3 9 15.032 60 18/5, 7 Distal 14.9 10,140 10 35.8 G44810 C-UTLMYJ-901J-RSC-ABRM-HC-FST-A-RD 3 9 20.032 60 18/5, 7 Distal 14.9 10,140 10 35.8 G44816 C-UTLMYJ-901J-LSC-ABRM-HC-FST-A-RD 3 9 25.032 60 18/5, 7 Distal 14.9 10,140 10 35.8 G44804 C-UQLMYJ-1001J-ABRM-HC-FST-A-RD 5 10 15.032 60 18/5,7 Distal 14 1 8,820 10 32.1 G44800 C-UQLMYJ-1001J-RSC-ABRM-HC-FST-A-RD 5 10 20.032 60 18/5, 7 Distal 14 1 8,820 10 32.1 G44803 C-UQLMYJ-1001J-LSC-ABRM-HC-FST-A-RD 5 10 25.032 60 18/5, 7 Distal 14 1 8,820 10 32.1 /sec Average Hub Pressure at Flow psi 8

COOK SPECTRUM CVC SETS WITH STANDARD COMPONENTS Cook Spectrum CVC sets WITH STANDARD COMPONENTS Part Cross-section s G43984 C-UDLM-401J-PED-ABRM-HC 2 4 5.018 30 21/4 Distal 20.2 780 G43983 C-UDLM-401J-ABRM-HC 2 4 8.018 40 21/4 Distal 20.2 780 G43986 C-UDLM-401J-LSC-ABRM-HC 2 4 15.018 50 21/4 Distal 20.2 780 G24754 C-UDLM-401J-ABRM-HC-CAH 2 4 8.018 40 21/4 Distal 20.2 780 G24756 C-UDLM-401J-LSC-ABRM-HC-CAH 2 4 15.018 50 21/4 Distal 20.2 780 G24752 C-UDLM-401J-PED-ABRM-HC-CAH 2 4 5.018 30 21/4 Distal 20.2 780 G43985 C-UDLM-401J-RSC-ABRM-HC 2 4 12.018 40 21/4 Distal 20.2 780 G24755 C-UDLM-401J-RSC-ABRM-HC-CAH 2 4 12.018 40 21/4 Distal 20.2 780 G43995 C-UDLM-501J-ABRM-HC 2 5 8.018 40 21/4 Distal 20.2 900 G24758 C-UDLM-501J-ABRM-HC-CAH 2 5 8.018 40 21/4 Distal 20.2 900 G24760 C-UDLM-501J-LSC-ABRM-HC-CAH 2 5 15.018 50 21/4 Distal 20.2 900 G43998 C-UDLM-501J-LSC-ABRM-HC 2 5 15.018 50 21/4 Distal 20.2 900 G43997 C-UDLM-501J-RSC-ABRM-HC 2 5 12.018 40 21/4 Distal 20.2 900 G43996 C-UDLM-501J-PED-ABRM-HC 2 5 5.018 30 21/4 Distal 20.2 900 G24757 C-UDLM-501J-PED-ABRM-HC-CAH 2 5 5.018 30 21/4 Distal 20.2 900 G43997 C-UDLM-501J-RSC-ABRM-HC 2 5 12.018 40 21/4 Distal 20.2 900 G24759 C-UDLM-501J-RSC-ABRM-HC-CAH 2 5 12.018 40 21/4 Distal 20.2 900 9

COOK SPECTRUM CVC SETS WITH STANDARD COMPONENTS Cook Spectrum CVC sets WITH STANDARD COMPONENTS Part Cross-section s G44006 C-UTLM-501J-PED-ABRM-HC 3 5 5.025 30 19/4 Distal 18.3 1,200 - - /sec Average Hub Pressure at Flow psi G44005 C-UTLM-501J-ABRM-HC 3 5 8.025 40 19/4 Distal 18.3 1,200 - - G24803 C-UTLM-501J-ABRM-HC-CAH 3 5 8.025 40 19/4 Distal 18.3 1,200 - - G24805 C-UTLM-501J-LSC-ABRM-HC-CAH 3 5 15.025 50 19/4 Distal 18.3 1,200 - - G24804 C-UTLM-501J-PED-ABRM-HC-CAH 3 5 5.025 30 19/4 Distal 18.3 1,200 - - G24765 C-UTLM-501J-RSC-ABRM-HC-CAH 3 5 12.025 40 19/4 Distal 18.3 1,200 - - G44007 C-UTLM-501J-RSC-ABRM-HC 3 5 12.025 40 19/4 Distal 18.3 1,200 - - G44008 C-UTLM-501J-LSC-ABRM-HC 3 5 15.025 50 19/4 Distal 18.3 1,200 - - G47825 C-UTLM-701J-ABRM-HC-RD 3 7 15.032 60 18/7 Distal 16.6 3,840 10 143.3 G47829 C-UTLM-701J-RSC-ABRM-HC-RD 3 7 20.032 60 18/7 Distal 16.6 3,840 10 143.3 G47827 C-UTLM-701J-LSC-ABRM-HC-RD 3 7 25.032 60 18/7 Distal 16.6 3,840 10 143.3 G24809 C-UTLM-701J-ABRM-HC-RD-CAH 3 7 15.032 60 18/5, 18/7 Distal 16.6 3,840 10 143.3 10

COOK SPECTRUM CVC SETS WITH STANDARD COMPONENTS Cook Spectrum CVC sets WITH STANDARD COMPONENTS Part Cross-section s G24810 C-UTLM-701J-RSC-ABRM-HC-RD-CAH 3 7 20.032 60 18/5, 18/7 Distal 16.6 3,840 10 143.3 G24812 C-UTLM-701J-LSC-ABRM-HC-RD-CAH 3 7 25.032 60 18/5, 18/7 Distal 16.6 3,840 10 143.3 G50817 C-UDLM-801J-ABRM-HC 2 8 15.032 60 18/5, 18/7 Distal 14.9 6,780 - - G50818 C-UDLM-801J-RSC-ABRM-HC 2 8 20.032 60 18/5, 18/7 Distal 14.9 6,780 10 55.1 G24716 C-UDLM-801J-ABRM-HC-CAH 2 8 15.032 60 18/5, 18/7 Distal 14.9 6,780 10 55.1 G24718 C-UDLM-801J-LSC-ABRM-HC-CAH 2 8 25.032 60 18/5, 18/7 Distal 14.9 6,780 10 55.1 G24717 C-UDLM-801J-RSC-ABRM-HC-CAH 2 8 20.032 60 18/5, 18/7 Distal 14.9 6,780 10 55.1 G24719 C-UTLM-901J-ABRM-HC-RD-CAH 3 9 15.032 60 18/5, 18/7 Distal 14.9 10,140 10 35.8 G24721 C-UTLM-901J-LSC-ABRM-HC-RD-CAH 3 9 25.032 60 18/5, 18/7 Distal 14.9 10,140 10 35.8 G24722 C-UTLM-901J-RSC-ABRM-HC-RD-CAH 3 9 20.032 60 18/5, 18/7 Distal 14.9 10,140 10 35.8 /sec Average Hub Pressure at Flow psi 11

COOK SPECTRUM CVC SETS WITH STANDARD COMPONENTS Cook Spectrum CVC sets WITH STANDARD COMPONENTS Part Cross-section s G51537 C-UQLM-1001J-ABRM-HC-RD 5 10 15.032 60 18/7 Distal 14 1 8,820 10 32.1 G51539 C-UQLM-1001J-RSC-ABRM-HC-RD 5 10 20.032 60 18/7 Distal 14 1 8,820 10 32.1 G24821 C-UQLM-1001J-ABRM-HC-RD-CAH 5 10 15.032 60 18/5, 18/7 Distal 14 1 8,820 10 32.1 G24823 C-UQLM-1001J-LSC-ABRM-HC-RD-CAH 5 10 25.032 60 18/5, 18/7 Distal 14 1 8,820 10 32.1 /sec Average Hub Pressure at Flow psi G24822 C-UQLM-1001J-RSC-ABRM-HC-RD-CAH 5 10 20.032 60 18/5, 18/7 Distal 14 1 8,820 10 32.1 12

UNIMPREGNATED CVC TRAYS WITH MSB COMPONENTS Unimpregnated CVC trays WITH MSB COMPONENTS Part Cross-section s G44789 C-UTLMYJ-701J-RSC-IHI-CCT-A-RD 3 7 20.032 60 18/5, 18/7 Distal 16.6 3,840 10 143.3 G44790 C-UTLMYJ-701J-IHI-CCT-A-RD 3 7 15.032 60 18/5, 18/7 Distal 16.6 3,840 10 143.3 G44798 C-UDLMYJ-801J-IHI-CCT-A 2 8 15.032 60 18/5, 18/7 Distal 14.9 6,780 10 55.1 G44799 C-UDLMYJ-801J-RSC-IHI-CCT-A 2 8 20.032 60 18/5, 18/7 Distal 14.9 6,780 10 55.1 /sec Average Hub Pressure at Flow psi 13

UNIMPREGNATED CVC TRAYS WITHOUT MSB COMPONENTS Unimpregnated CVC trays WITHOUT MSB COMPONENTS Part Cross-section s G07246 C-UDLMYJ-401J 2 4 8.018 40 21/4 Distal 20.2 780 - - - - G05634 C-UDLMYJ-401J-PED 2 4 5.018 30 21/4 Distal 20.2 780 - - - - G07029 C-UDLMYJ-501J-PED 2 5 5.018 30 21/4 Distal 20.2 900 - - - - G07027 C-UTLMYJ-501J 3 5 8.025 40 19/4 Distal 18.3 1,200 - - G07132 C-UTLMYJ-501J-LSC 3 5 15.025 50 19/4 Distal 18.3 1,200 - - G07026 C-UTLMYJ-501J-PED 3 5 5.025 30 19/4 Distal 18.3 1,200 - - G07028 C-UTLMYJ-501J-RSC 3 5 12.025 40 19/4 Distal 18.3 1,200 - - G44787 C-UTLMYJ-701J-CCT-A-RD 3 7 15.032 60 18/5, 18/7 Distal 16.6 3,840 10 143.3 G44788 C-UTLMYJ-701J-RSC-CCT-A-RD 3 7 20.032 60 18/5, 18/7 Distal 16.6 3,840 10 143.3 G44791 C-UTLMYJ-701J-LSC-CCT-A-RD 3 7 25.032 60 18/5, 18/7 Distal 16.6 3,840 10 143.3 G44796 C-UDLMYJ-801J-CCT-A 2 8 15.032 60 18/5, 18/7 Distal 14.9 6,780 10 55.1 G44797 C-UDLMYJ-801J-RSC-CCT-A 2 8 20.032 60 18/5, 18/7 Distal 14.9 6,780 10 55.1 G44805 C-UQLMYJ-1001J-RSC-IHI-CCT-A-RD 5 10 20.032 60 18/5, 18/7 Distal 14 1 8,820 10 32.1 /sec Average Hub Pressure at Flow psi 14

UNIMPREGNATED CVC SETS WITH STANDARD COMPONENTS Unimpregnated CVC sets WITH STANDARD COMPONENTS Part Cross-section s G24677 C-UDLM-401J-CAH 2 4 8.018 40 21/4 Distal 20.2 780 G24679 C-UDLM-401J-LSC-CAH 2 4 15.018 50 21/4 Distal 20.2 780 G04035 C-UDLM-401J 2 4 8.018 40 21/4 Distal 20.2 780 G04186 C-UDLM-401J-LSC 2 4 15.018 50 21/4 Distal 20.2 780 G04133 C-UDLM-401J-PED 2 4 5.018 30 21/4 Distal 20.2 780 G24676 C-UDLM-401J-PED-CAH 2 4 5.018 30 21/4 Distal 20.2 780 G04176 C-UDLM-401J-RSC 2 4 12.018 40 21/4 Distal 20.2 780 G24678 C-UDLM-401J-RSC-CAH 2 4 12.018 40 21/4 Distal 20.2 780 G03997 C-UDLM-501J 2 5 8.018 40 21/4 Distal 20.2 900 G24699 C-UDLM-501J-CAH 2 5 8.018 40 21/4 Distal 20.2 900 G04083 C-UDLM-501J-LSC 2 5 15.018 50 21/4 Distal 20.2 900 G24701 C-UDLM-501J-LSC-CAH 2 5 15.018 50 21/4 Distal 20.2 900 G04022 C-UDLM-501J-PED 2 5 5.018 30 21/4 Distal 20.2 900 G24698 C-UDLM-501J-PED-CAH 2 5 5.018 30 21/4 Distal 20.2 900 G04013 C-UDLM-501J-RSC 2 5 12.018 40 21/4 Distal 20.2 900 G24700 C-UDLM-501J-RSC-CAH 2 5 12.018 40 21/4 Distal 20.2 900 15

UNIMPREGNATED CVC SETS WITH STANDARD COMPONENTS Unimpregnated CVC sets WITH STANDARD COMPONENTS Part Cross-section s G24762 C-UTLM-501J-CAH 3 5 8.025 40 19/4 Distal 18.3 1,200 - - /sec Average Hub Pressure at Flow psi G24764 C-UTLM-501J-LSC-CAH 3 5 15.025 50 19/4 Distal 18.3 1,200 - - G24763 C-UTLM-501J-PED-CAH 3 5 5.025 30 19/4 Distal 18.3 1,200 - - G24761 C-UTLM-501J-RSC-CAH 3 5 12.025 40 19/4 Distal 18.3 1,200 - - G04135 C-UTLM-501J 3 5 8.025 40 19/4 Distal 18.3 1,200 - - G04185 C-UTLM-501J-LSC 3 5 15.025 50 19/4 Distal 18.3 1,200 - - G04134 C-UTLM-501J-PED 3 5 5.025 30 19/4 Distal 18.3 1,200 - - G04136 C-UTLM-501J-RSC 3 5 12.025 40 19/4 Distal 18.3 1,200 - - G24808 C-UTLM-701J-LSC-RD-CAH 3 7 25.032 60 18/5, 18/7 Distal 16.6 3,840 10 143.3 G24806 C-UTLM-701-RD-CAH 3 7 15.032 60 18/5, 18/7 Distal 16.6 3,840 10 143.3 G24807 C-UTLM-701J-RSC-RD-CAH 3 7 20.032 60 18/5, 18/7 Distal 16.6 3,840 10 143.3 16

UNIMPREGNATED CVC SETS WITH STANDARD COMPONENTS Unimpregnated CVC sets WITH STANDARD COMPONENTS Part Cross-section s G24704 C-UDLM-801J-CAH 2 8 15.032 60 18/5, 18/7 Distal 14.9 6,780 10 55.1 /sec Average Hub Pressure at Flow psi G24705 C-UDLM-801J-RSC-CAH 2 8 20.032 60 18/5, 18/7 Distal 14.9 6,780 10 55.1 G12863 C-UTLM-901J 3 9 15.035 60 18/7 Distal 14.9 10,140 - - G24816 C-UTLM-901J-LSC-RD-CAH 3 9 25.032 60 18/5, 18/7 Distal 14.9 10,140 10 35.8 G24814 C-UTLM-901J-RD-CAH 3 9 15.032 60 18/5, 18/7 Distal 14.9 10,140 10 35.8 G12864 C-UTLM-901J-RSC 3 9 20.035 60 18/7 Distal 14.9 10,140 - - G24815 C-UTLM-901J-RSC-RD-CAH 3 9 20.032 60 18/5, 18/7 Distal 14.9 10,140 10 35.8 17

UNIMPREGNATED CVC SETS WITH STANDARD COMPONENTS Unimpregnated CVC sets WITH STANDARD COMPONENTS Part Cross-section s G24817 C-UQLM-1001J-RD-CAH 5 10 15.032 60 18/5, 18/7 Distal 14 1 8,820 10 32.1 /sec Average Hub Pressure at Flow psi G51533 C-UQLM-1001J-RSC-RD 5 10 20.032 60 18/7 Distal 14 1 8,820 10 32.1 G24818 C-UQLM-1001J-RSC-RD-CAH 5 10 20.032 60 18/5, 18/7 Distal 14 1 8,820 10 32.1 18

MEDICAL COOK 11/2018 CC-D34769-EN-F