Susceptibility Testing and Resistance Phenotypes Detection in Bacterial Pathogens Using the VITEK 2 System

Similar documents
2012 ANTIBIOGRAM. Central Zone Former DTHR Sites. Department of Pathology and Laboratory Medicine

THE NAC CHALLENGE PANEL OF ISOLATES FOR VERIFICATION OF ANTIBIOTIC SUSCEPTIBILITY TESTING METHODS

MICRONAUT MICRONAUT-S Detection of Resistance Mechanisms. Innovation with Integrity BMD MIC

2016 Antibiogram. Central Zone. Alberta Health Services. including. Red Deer Regional Hospital. St. Mary s Hospital, Camrose

2015 Antibiogram. Red Deer Regional Hospital. Central Zone. Alberta Health Services

2017 Antibiogram. Central Zone. Alberta Health Services. including. Red Deer Regional Hospital. St. Mary s Hospital, Camrose

2016 Antibiotic Susceptibility Report

CONTAGIOUS COMMENTS Department of Epidemiology

Mercy Medical Center Des Moines, Iowa Department of Pathology. Microbiology Department Antibiotic Susceptibility January December 2016

2015 Antibiotic Susceptibility Report

Chemotherapy of bacterial infections. Part II. Mechanisms of Resistance. evolution of antimicrobial resistance

Intrinsic, implied and default resistance

ESBL Producers An Increasing Problem: An Overview Of An Underrated Threat

Antimicrobial Susceptibility Testing: Advanced Course

Concise Antibiogram Toolkit Background

Antibiotic. Antibiotic Classes, Spectrum of Activity & Antibiotic Reporting

Background and Plan of Analysis

BACTERIAL SUSCEPTIBILITY REPORT: 2016 (January 2016 December 2016)

European Committee on Antimicrobial Susceptibility Testing

Tel: Fax:

EUCAST Subcommitee for Detection of Resistance Mechanisms (ESDReM)

2015 Antimicrobial Susceptibility Report

2010 ANTIBIOGRAM. University of Alberta Hospital and the Stollery Children s Hospital

New Opportunities for Microbiology Labs to Add Value to Antimicrobial Stewardship Programs

Suggestions for appropriate agents to include in routine antimicrobial susceptibility testing

INFECTIOUS DISEASES DIAGNOSTIC LABORATORY NEWSLETTER

Performance Information. Vet use only

Mili Rani Saha and Sanya Tahmina Jhora. Department of Microbiology, Sir Salimullah Medical College, Mitford, Dhaka, Bangladesh

Helen Heffernan and Rosemary Woodhouse Antibiotic Reference Laboratory

a. 379 laboratories provided quantitative results, e.g (DD method) to 35.4% (MIC method) of all participants; see Table 2.

APPENDIX III - DOUBLE DISK TEST FOR ESBL

European Committee on Antimicrobial Susceptibility Testing

Educating Clinical and Public Health Laboratories About Antimicrobial Resistance Challenges

ESBL- and carbapenemase-producing microorganisms; state of the art. Laurent POIREL

RCH antibiotic susceptibility data

ENTEROCOCCI. April Abbott Deaconess Health System Evansville, IN

Help with moving disc diffusion methods from BSAC to EUCAST. Media BSAC EUCAST

2009 ANTIBIOGRAM. University of Alberta Hospital and the Stollery Childrens Hospital

Prevalence of Extended-spectrum β-lactamase Producing Enterobacteriaceae Strains in Latvia

CONTAGIOUS COMMENTS Department of Epidemiology

ESCMID Online Lecture Library. by author

Aberdeen Hospital. Antibiotic Susceptibility Patterns For Commonly Isolated Organisms For 2015

ESCMID Online Lecture Library. by author

The Basics: Using CLSI Antimicrobial Susceptibility Testing Standards

Original Article. Suthan Srisangkaew, M.D. Malai Vorachit, D.Sc.

INCIDENCE OF BACTERIAL COLONISATION IN HOSPITALISED PATIENTS WITH DRUG-RESISTANT TUBERCULOSIS

Understanding the Hospital Antibiogram

C&W Three-Year Cumulative Antibiogram January 2013 December 2015

Bacterial Pathogens in Urinary Tract Infection and Antibiotic Susceptibility Pattern from a Teaching Hospital, Bengaluru, India

Table 1. Commonly encountered or important organisms and their usual antimicrobial susceptibilities.

CONTAGIOUS COMMENTS Department of Epidemiology

Quality assurance of antimicrobial susceptibility testing

Prevalence of Metallo-Beta-Lactamase Producing Pseudomonas aeruginosa and its antibiogram in a tertiary care centre

Service Delivery and Safety Department World Health Organization, Headquarters

Michael Hombach*, Guido V. Bloemberg and Erik C. Böttger

Evaluation of the BIOGRAM Antimicrobial Susceptibility Test System

Original Article. Ratri Hortiwakul, M.Sc.*, Pantip Chayakul, M.D.*, Natnicha Ingviya, B.Sc.**

EXTENDED-SPECTRUM BETA-LACTAMASE (ESBL) TESTING

جداول میکروارگانیسم های بیماریزای اولویت دار و آنتی بیوتیک های تعیین شده برای آزمایش تعیین حساسیت ضد میکروبی در برنامه مهار مقاومت میکروبی

4 th and 5 th generation cephalosporins. Naderi HR Associate professor of Infectious Diseases

Guidelines for Laboratory Verification of Performance of the FilmArray BCID System

Available online at ISSN No:

ANTIMICROBIAL SUSCEPTIBILITY VANCOMYCIN RESISTANCE IN AN UNCOMMON ENTEROCOCCAL SPECIES

EUCAST recommended strains for internal quality control

Antimicrobial Resistance Strains

Original Article. Hossein Khalili a*, Rasool Soltani b, Sorrosh Negahban c, Alireza Abdollahi d and Keirollah Gholami e.

Antimicrobial susceptibility

Mechanism of antibiotic resistance

Antimicrobial Susceptibility Testing: The Basics

ANTIMICROBIAL RESISTANCE SURVEILLANCE FROM SENTINEL PUBLIC HOSPITALS, SOUTH AFRICA, 2014

EARS Net Report, Quarter

Detection of inducible clindamycin resistance among clinical isolates of Staphylococcus aureus in a tertiary care hospital

Epidemiology and Microbiology of Surgical Wound Infections

Antimicrobial Stewardship Strategy: Antibiograms

In Vitro Antimicrobial Activity of CP-99,219, a Novel Azabicyclo-Naphthyridone

Finnzymes Oy. PathoProof Mastitis PCR Assay. Real time PCR based mastitis testing in milk monitoring programs

microbiology testing services

UNDERSTANDING YOUR DATA: THE ANTIBIOGRAM

Evaluation of a computerized antimicrobial susceptibility system with bacteria isolated from animals

Antimicrobial Resistance Surveillance from sentinel public hospitals, South Africa, 2013

Over the past several decades, the frequency of. Resistance Patterns Among Nosocomial Pathogens* Trends Over the Past Few Years. Ronald N.

Antimicrobial Susceptibility Patterns

Florida Health Care Association District 2 January 13, 2015 A.C. Burke, MA, CIC

Routine internal quality control as recommended by EUCAST Version 3.1, valid from

BactiReg3 Event Notes Module Page(s) 4-9 (TUL) Page 1 of 21

Childrens Hospital Antibiogram for 2012 (Based on data from 2011)

Received: February 29, 2008 Revised: July 22, 2008 Accepted: August 4, 2008

Appropriate antimicrobial therapy in HAP: What does this mean?

Short Report. R Boot. Keywords: Bacteria, antimicrobial susceptibility testing, quality, diagnostic laboratories, proficiency testing

GENERAL NOTES: 2016 site of infection type of organism location of the patient

Main objectives of the EURL EQAS s

Leveraging the Lab and Microbiology Department to Optimize Stewardship

Doripenem: A new carbapenem antibiotic a review of comparative antimicrobial and bactericidal activities

Antimicrobial Cycling. Donald E Low University of Toronto

QUICK REFERENCE. Pseudomonas aeruginosa. (Pseudomonas sp. Xantomonas maltophilia, Acinetobacter sp. & Flavomonas sp.)

The β- Lactam Antibiotics. Munir Gharaibeh MD, PhD, MHPE School of Medicine, The University of Jordan November 2018

against Clinical Isolates of Gram-Positive Bacteria

Can we trust the Xpert?

Defining Extended Spectrum b-lactamases: Implications of Minimum Inhibitory Concentration- Based Screening Versus Clavulanate Confirmation Testing

What s new in EUCAST methods?

Transcription:

Polish Journal of Microbiology 2005, Vol. 54, No 4, 311 316 Susceptibility Testing and Resistance Phenotypes Detection in Bacterial Pathogens Using the VITEK 2 System EL BIETA STEFANIUK*, AGNIESZKA MRÓWKA and WALERIA HRYNIEWICZ Department of Epidemiology and Clinical Microbiology, National Institute of Public Health Che³mska str. 30/34, 00-725 Warsaw, Poland Received.23 August 2005, received in revised form 20 November 2005, accepted 21 November 2005 Abstract A set of well characterized strains, collected in Polish hospitals, including Gram-negative (n = 93) and Gram-positive (n = 90) isolates was used in the study. The VITEK 2 AST-cards were used in the analysis according to the manufacturer s recommendations. Comparison of the susceptibility data obtained by the standard method and by VITEK 2 cards proved concordant in 99% of cases. Clinically important mechanisms were revealed by the VITEK 2 AES with >95% agreement with reference data including methicillin resistance in staphylococci (98%), high-level aminoglycoside resistance in enterococci (100%), VanA and VanB phenotypes in enterococci (100%), and ESBLs in Enterobacteriaceae (93.8%). The VITEK 2 AES System appears a reliable tool for the detection and interpretive reading of clinically important mechanisms of resistance and can be recommended for routine work. K e y w o r d s: bacterial pathogens, antimicrobial agents, susceptibility testing, resistance mechanisms, VITEK 2 Introduction Increasing resistance in bacterial pathogens of high clinical relevance requires proper and rapid detection of the resistance phenotype. Dilution methods are the reference methods used in determining microorganisms susceptibility which allow the determination of the minimal inhibitory concentration of the drug (MIC) and thus the proper choice of antimicrobial agents for therapy. Following the emergence of many mechanisms of resistance special methods for their detection, allowing full expression of resistance mechanisms in vitro, are more often applied. Different phenotypic methods are used, supplemented by molecular biology techniques. However the main drawback in the majority phenotype methods used is the time required to obtain results. For many years the automation of microbiological diagnostics has been developing dynamically. New automated microbiology systems create opportunities for quickly obtaining complete microbiological results. Changes in the spectrum of etiological agents and their susceptibility profiles demand the continous improvement of such systems and their adjustment to new epidemiological situations. The VITEK 2 System (biomérieux, USA) belongs to the new generation of automated microbiology systems designed to identify bacterial isolates to the species level and to determine their drug susceptibility. The system provides different types of card used for identification tests and for drug susceptibility determination. The aim of this study was to evaluate the VITEK 2 Automated System for antimicrobial susceptibility determination of the most important clinical pathogens and the Advanced Expert System (AES) for its interpretation of resistance mechanisms. The results of the analyses were compared with those obtained by reference microbiological methods. * Department of Epidemiology and Clinical Microbiology, National Institute of Public Health, Che³mska str. 30/34, 00-725 Warsaw, Poland; e-mail: estafaniuk@cls.edu.pl

312 Stefaniuk E. et al. 4 Experimental Materials and Methods Bacterial strains. A total of 183 clinically significant Gram-negative (n = 93) and Gram-positive (n = 90) bacterial pathogens were included in the study. Gram-negative organisms represented seven of the most commonly encountered species of the family Enterobacteriaceae (Escherichia coli n = 23, Klebsiella pneumoniae n = 18, Klebsiella oxytoca n=3, Proteus mirabilis n=2, Serratia marcescens n=9, Enterobacter cloacae n = 13, Citrobacter freundii n = 5) and two species of nonfermenting rods (Acinetobacter baumannii n = 10, Pseudomonas aeruginosa n = 10). Gram-positive isolates belonged to four Staphylococcus species (S. aureus n = 42, S. epidermidis n=4, S. haemolyticus n=3, S. hominis n = 1), two species of Enterococcus (E. faecalis n = 10, E. faecium n = 10) and Streptococcus pneumoniae (n = 20). The isolates were recovered from specimens collected from patients hospitalised in different medical centers in Poland from 1996 to 2002. All strains were collected by the National Institute of Public Health. They were not epidemiologically related and represented one isolate per patient. A wide variety of clinically important antimicrobial resistance mechanisms were represented by the isolates, including extended-spectrum $-lactamases (ESBLs) in Enterobacteriaceae (48 isolates), methicillin resistance in staphylococci (37 isolates), decreased pneumococcal susceptibility to penicillin (8 isolates) and resistance to vancomycin and to high concentrations of aminoglycosides in enterococci (8 and 20 isolates, respectively). E. coli ATCC 25922, E. coli ATCC 35218, E. faecalis ATCC 29212, E. faecalis ATCC 51299, K. pneumoniae ATCC 700603 P. aeruginosa ATCC 27853, S. pneumoniae ATCC 49619, S. aureus ATCC 29213, S. aureus ATCC 25923, S. aureus ATCC 43300 and S. aureus MR3 from the collection of the National Insitute of Public Health in Warsaw were used as reference strains. Identification methods. Gram-negative isolates were identified to the species level by API 20 E (Enterobacteriaceae) or API 20 NE (non-fermenters) biochemical tests (biomérieux, Marcy l Etoile, France). S. aureus was identified by coagulase production (bound and free), supplemented by DN-ase test, and coagulase-negative staphylococci were speciated by the API Staph test (biomérieux, Charbonnieres-les-Bains, France). Identification of the enterococcal isolates was performed according to the method of Facklam and Collins (Facklam and Collins, 1989) and by the API 20 Strep test (biomérieux, Charbonnieres-les-Bains, France), supplemented by potassium tellurite reduction, motility, and pigment production tests (Facklam and Collins, 1989). S. pneumoniae was identified using standard microbiology techniques including agar morphology, optochin test and bile solubility test (Ruoff et al., 1999). MIC evaluation. MICs of various antimicrobials were evaluated by agar or broth dilution methods in accordance with the Clinical and Laboratory Standards Institute (CLSI/ NCCLS National Committee for Clinical Laboratory Standards) guidelines (NCCLS, 2003a.; CLSI, 2005). The same antimicrobial agents were tested as those that were present in the VITEK 2 cards used in the study, and specific sets of agents were selected for each of the species analysed. The following antimicrobials were included in the study: penicillin, cefotaxime, streptomycin and gentamicin (Polfa Tarchomin, Poland); amoxicillin, clavulanic acid and oxacillin and ceftazidime (Glaxo SmithKline, UK); piperacillin, and tazobactam (Wyeth, USA); cefepime and amikacin (Bristol-Myers Squibb, USA); meropenem (Zeneca, UK), ciprofloxacin (Bayer, Germany); vancomycin (Eli Lilly, USA); teicoplanin (Marion Merrell, UK). In $-lactam-inhibitor combinations, concentrations used were in accordance with the CLSI (CLSI, 2005). Detection of methicillin resistance. Methicillin resistance was detected in staphylococcal isolates by two methods recommended by the CLSI, using a 30mg cefoxitine disc and the agar screening method (CLSI, 2005; NCCLSb., 2003). The screening method was used only for S. aureus isolates. Results of the analysis were confirmed by the PCR amplification of the meca gene in all methicillin-resistant isolates as described previously (Murakami et al., 1991). Detection of the high-level aminoglycoside resistance (HLAR) and vancomycin resistance in Enterococcus spp. Enterococcal isolates were tested for the presence of the HLAR phenotype using the agar screening method as described by CLSI (CLSI, 2005; NCCLSb., 2003). Vancomycin-resistant enterococci (VRE) were identified by the CLSI agar screening procedure (NCCLS, 2003a.; CLSI, 2005) and positive results of the test were confirmed by PCR detection of vana or vanb genes as described previously (Dutka-Malen et al., 1995; Dahl et al., 1999). Detection of penicillin resistance in S. pneumoniae. Penicillin-resistant S. pneumoniae strains were identified by two methods recommended by CLSI: screening method with the 1mg oxacillin disc and the reference broth dilution method (NCCLS, 2003a.; CLSI, 2005). ESBL detection. ESBL activity was detected in Enterobacteriaceae isolates by the double disc synergy (DDS) test (Jarlier et al., 1988) with discs containing cefotaxime, ceftazidime and amoxicillin/clavulanate. The 48 DDS test-positive isolates included 15 Klebsiella pneumoniae, 2 Klebsiella oxytoca, 17 Escherichia coli, 5 Serratia marcescens, 7 Enterobacter cloacae and 2 Citrobacter freundii isolates. These were recovered in 7 different Polish hospitals in 1996 98, and were confirmed to be ESBL producers by biochemical and molecular methods (isoelectric focusing, bioassay, PCR and sequencing) published before (Pa³ucha et al., 1999; Fiett et al., 2000). VITEK 2 tests. Analysis was conducted with the use of antibiogram cards VITEK 2 (for Gram-positive cocci: AST-524, -526 and -GP56; for Gram-negative rods: AST-N019, -N020, -N021). The tests are in the form of small, waterproof cards with 64 wells containing antibacterial drugs (antibiogram tests) in different dilutions suitable for testing microorganisms according to the CLSI recommendations. Tests were performed according to the manufacturer s instruction. Evaluated parameters. Characteristic parameters of the automatic method of drug susceptibility determination were defined: total concordance of resistance categories (CA), accuracy, sensitivity, specificity and type of errors (me, ME, VME). Minimal error me was recognised when one of the methods reference or evaluated (in this study automatic method) identified the tested strain as intermediate, where the other method classified it as resistant or sensitive. Major error ME reference method sensitive and automatic method resistant. Very major error VME reference method resistant, whereas automatic method sensitive. Additional parameters were also evaluated such as time taken to obtain results, functionality and level of difficulty in using the system.

4 Susceptibility testing by VITEK 2 system 313 Results MIC values and interpretation. A high correlation was found between the results (n = 1882 susceptibility tests) obtained by the aid of VITEK 2 and by the dilution reference method. The total accordance of resistance interpretation was 99%. For the species of Enterobacteriaceae family CA was 98.8%. Single minor errors (me) in MIC values were observed for gentamicin, amikacin and piperacillin. One major error (ME) appeared when testing E. cloacae susceptibility to piperacillin with tazobactam. In the group of nonfermenting rods CA obtained was 96.4% for A. baumannii (4 me), and 99.2% for P. aeruginosa (1 me). The interpretation of the carbapenems MIC value for nonfermenting rods was in 100% consistent with the interpretation of the MIC value defined with the reference methods. Susceptibility tests for Gram-positive cocci exhibited an accordance variation from 97.8% for pneumococci, 98% and 99% respectively for E. faecium and E. faecalis, to 99.5% for staphylococci. In this group of microorganisms one very major error VME (for S. aureus and oxacillin) was noted. Comparative analysis of the interpretation of glycopeptide MICs (vancomycin and teicoplanin) obtained for enterococci, and penicillin MIC values for pneumococci, showed one minor error in both cases. All types of errors encountered in the respective species are presented in Table I. Species [No of isolates with errors/no of all isolates] Table I Discrepanciens between the VITEK 2 results and reference methods results Antimicrobial agent / No and kind of errors Reference method MIC [mg/l] / category of susceptibility VITEK 2 MIC [mg/l] / category of susceptibility Penicillin / 1 me 1 I 2 R S. pneumoniae [n = 3/20] Ceftriaxon / 2 me 2 I 4 R Cefotaxime / 1 me 0.5 S 1 I S. aureus [n = 1/50] Oxacillin /1 VME 64 R 2 S E. faecalis [n = 1/10] Ciprofloxacin /1 me 2 I 0.5 S E. faecium [n = 2/10] Ciprofloxacin / 1 me 4 R 2 I Teicoplanin / 1 me 32 R 16 I Piperacillin / 1 me 256 R 64 I E. coli [n = 3/23] Gentamicin / 1 me 32 R 8 I Amikacin / 2 me 64 R 32 I 16 S 32 I Gentamicin / 1 me 8 I 16 R K. pneumoniae [n = 3/18] Amikacin / 2 me 32 I 16 S 16 S 32 I K. oxytoca [n = 1/3] Gentamicin / 1 me 8 I 16 R E. cloacae [n = 2/13] Piperacillin/Tazobactam / 1 ME 2 S 128 R Gentamicin / 1 me 4 S 8 I S. marcescens [n = 2/9] Gentamicin / 1 me 8 I 16 R Cefoxitin / 1 me 16 I 32 R Piperacillin/Tazobactam / 1 me 128 16 64 I A. baumannii [n = 3/10] Cefotaxim / 1 me 32 R 64 R Cefepime / 2 me 16 I 32 R 16 I 8 S P. aeruginosa [n = 2/10] Cefepime / 1 me 16 I 8 S me minor error; ME major error; VME very major error; S sensitive; I intermediate; R resistant Resistance phenotype detection and interpretation. ESBLs detection was not achieved by the VITEK 2 system in 3 isolates only. Two of these were E. cloacae and one C. freundii. The strains of these species produce cefalosporinase that is AmpC specific for those individual species, which when produced at a high level can mask the ESBL phenotype. In general good results were obtained, with 93.8% sensitivity, 95.9% accuracy and 100% specificity of detection of ESBL production by Enterobacteriaceae strains (for E. coli, K. pneumoniae and K. oxytoca all parameters reached the level of 100%). In the case of staphylococci 97.3% sensitivity, 98% accuracy and 100% specificity in the detection of MRS strains (methicillin resistant Staphylococcus) was achieved. One isolate of S. aureus characterised

314 Stefaniuk E. et al. 4 by the presence of meca gene showed an MIC value for oxacillin of 64 mg/l by the reference method and 2 mg/l by the VITEK 2 system. For enterococci, 100% accuracy, sensitivity and specificity was achieved for HLAR and VRE by VITEK 2 detection. The difference between teicoplanin MIC values described above had no influence on the susceptibility category. Detection of the resistance phenotype by the VITEK 2 system seldom resulted in a change of clinical interpretation of the sensitivity results for the respective drugs. High agreement between the results obtained with the automatic method and reference methods was achieved, as shown in Table II. Table II Characteristic features of VITEK 2 method in detection of selected resistance mechanisms MRSA HLAR VRE ESBL (all species) ESBL (E. cloacae, K. pneumoniae, K. oxytoca) Reference methods positive / VITEK 2 positive 36 20 8 45 35 Reference methods negative / VITEK 2 negative 13 0 12 25 9 Reference methods positive / VITEK 2 negative 1 0 0 3 0 Reference methods negative / VITEK 2 positive 0 0 0 0 0 Accuracy (%) 98 100 100 95.9 100 Sensitivity (%) 97.3 100 100 93.8 100 Specificity (%) 100 100 100 100 100 Times taken to obtain results by VITEK 2. The average time for results to be obtained using the VITEK 2 automatic system was 8 hours from the installation of the antibiogram cards. For Gram-positive cocci it required 9 hours and for Gram-negative rods 7 hrs 45 minutes. The shortest time recorded was for Klebsiella pneumoniae (5.5 hours) and the longest up to 17 hours for coagulase-negative staphylococci. Discussion The usefulness of microbiological diagnostics for patient care has been limited by the time taken for patient specimen processing and obtaining results. Thus a shortening and an improvement of this process is urgently needed in order to introduce etiologic agent specific therapy as early as possible. In this study VITEK 2, the new system offered by biomérieux, was evaluated in regard to its usefulness for antibiotic susceptibility testing, one of the most important steps in routine diagnostic microbiology. The great majority of isolates tested in this study, representing the most clinically relevant bacterial species, showed a high concordance of the results with the reference methods. However, they were obtained in a much shorter time, on average in 8 hours. This compared with 16 to 24 hrs needed for the reference methods. Although some molecular techniques are able to detect resistance genes in less than 4 hrs they have several limitations. They can only detect mechanisms of resistance that are already known and need to use several primers since more and more bacterial pathogens show multiple drug resistance. Favourable results when testing the VITEK 2 system have been also obtained by several other workers. Aissa and Horstkotte reported the high sensitivity and specificity of the system in the detection of methicillin resistance in staphylococcal strains as well as in S. aureus and coagulase-negative staphylococci (Aissa et al., 2004; Horstkotte et al., 2002). All strains but one (MRSA) were properly identified in respect to methicillin resistance. Ligozzi also obtained good agreement between results obtained by the reference methods and the VITEK 2 system, ranging from 90 100% for staphylococci, pneumococci and enterococci with an average of 96% (Ligozzi et al., 2002). In our study even higher concordance was obtained, 97.8% for pneumococci, 98 99% for enterococci and 99.5% for staphylococci. The results published by Blondell-Hill demonstrated a high agreement of 96.2% between the VITEK 2 system and reference method in the interpretation of antimicrobial susceptibility for 300 isolates of the Enterobacteriacae family (Blondell-Hill et al., 2003). Similar results were obtained in this study, with an even higher agreement of 98.8% achieved between the two methods. It should be stressed that in the case of the isolates of the Enterobacteriacae family, not even a single VME was encountered, and only one ME was reported for piperacillin/tazobactam combinations (E. cloacae). Similar results for E. cloacae and

4 Susceptibility testing by VITEK 2 system 315 piperacillin/tazobactam susceptibility were reported by Karlovsky on a very large number of isolates (Karlovsky et al., 2003). An important function of VITEK 2 is the interpretation of susceptibility data through the AES in reference to a major resistance mechanism. In our study, when ESBLs producing strains were tested, the mechanism was not identified in only 3 strains; all 3 strains belonged to AmpC producing species, with two representing E. cloacae and one representing C. freundii. The same problem was encountered in our previous study with BD Phoenix which was unable to detect ESBL in two strains of AmpC producing species (E. cloacae) (Stefaniuk et al, 2003). It seems that the presence of AmpC in those isolates makes detection of ESBL by AES impossible. Usually, ESBLs production is easily detectable in E. coli and Klebsiella spp. (Stefaniuk et al, 2003, Livermore, 1995, Leverstein-van Hall et al., 2002). However, Levenstein-van Hall comparing several methods of ESBL detection, such as E-test ESBL, BD Phoenix, Vitek 1 and Vitek 2, in 74 isolates of E. coli and K. pneumoniae, found an accuracy detection rate of 78% for the Vitek 2 (Leverstein-van Hall et al., 2002). This is in contrast to our study, which showed an excellent result of 100% ESBLs detection. The discrepancy between those two reports may result from the different bacterial populations under study, reflecting the complexity and diversity of these enzymes. The shorter time involved in getting susceptibility results, as compared to conventional methods, and their good correlation with those methods make the VITEK 2 automated microbiological system a useful device in clinical microbiological laboratory work. In addition, the VITEK 2 automated microbiological system is an aesthetically pleasing and userfriendly device. It should be operated by a qualified member the microbiological laboratory staff who has been trained by an experienced microbiologist. Accurate in vitro susceptibility testing methods are important for optional patient therapy, particularly for hospitalized patients, and for epidemiology study. As far as sensitivity, accuracy and specificity are concerned, antibiogram tests of the VITEK 2 system are comparable to other reference methods used to detect particular resistance mechanisms of clinically important bacterial strains. Acknowledgements. The authors wish to thank biomérieux company for the system VITEK 2 and all materials used in the VITEK 2 testing they provided. Literature A i s s a N., D. S t o l a r and P. L e g r a n d. 2004. Accuracy of four agar diffusion methods and Vitek 2 automated system for the detection of the methicillin resistance in coagulase negative staphylococci. Pathol. Biol. (Paris) 52: 26 32. Blondel-Hill E., C. Hetchler, D. Andrews and L. Lapointe. 2003. Evaluation of Vitek 2 to analysis of Enterobacteriaceae using the Advanced Expert System (AES) versus interpretative susceptibility guidelines used at Dynacare Kasper Medical Laboratories, Edmonton, Alberta. Clin. Microbiol. Infect. 9: 1091 103. Clinical and Laboratory Standards Institute. 2005. Performance standards for antimicrobial susceptibility testing; Fifteenth informational supplement: M100-S15. CLSI, Villanova, PA. Dahl K.H., G. Skov Simonsen, R. Olsvik and A. Sundsfjord. 1999. Heterogeneity in vanb gene cluster of genetically diverse clinical strains of vancomycin-resistant enterococci. Antimicrob. Agents Chemother. 43: 1105 1110. D u t k a - M a l e n S., S. E v e r s and P. C o u r v a l i n. 1995. Detection of glycopeptide resistance genotypes and identification to the species level of clinically relevant enterococci by PCR. J. Clin. Microbiol. 33: 24 27. Facklam R. and M.D. Collins. 1989. Identification of Enterococcus species isolated from human infections by a conventional test scheme. J Clin. Microbiol. 27: 731 734 Fiett J., A. Pa³ucha, B. Mi¹czyñska, M. Stankiewicz, H. Przondo-Mordarska, W. Hryniewicz and M. Gniadkowski. 2000. A novel complex mutant beta-lactamase, TEM-68, identified in a Klebsiella pneumoniae isolate from an outbreak of extended-spectrum beta-lactamase-producing klebsiellae. Antimicrob. Agents Chemother. 44: 1499 1505. Horstkotte M.A., J.K.M. Knobloch., H. Rohde, S. Dobinsky and D. Mack. 2002. Rapid detection of methicillin resistance in coagulase-negative staphylococci with the VITEK 2 system. J. Clin. Microbiol. 40: 3291 3295. J a r l i e r V., J.E. N i c o l a s, G. F o u r n i e r and A. P h i l i p p o n. 1988. Extended broad-spectrum $-lactamases conferring transferable resistance to newer $-lactam agents in Enterobacteriaceae: hospital prevalence and susceptibility patterns. Rev. Infect. Dis. 10: 2141 2143. Ligozzi M., C. Bernini, M.G. Bonora, M. de Fatima, J. Zuliani and R. Fontana. 2002. Evaluation of the Vitek 2 system for identification and antimicrobial susceptibility testing of medically relevant Gram-positive cocci. J. Clin. Microbiol. 40: 1681 1686. L i v e r m o r e D.M. 1995. $-Lactamases in laboratory and clinical resistance. Clin. Microbiol. Rev. 8: 557 58. L e v e r s t e i n - v a n H a l l M.A., A.C. F l u i t, A. P a a u w, A.T.A. B o x, S. B r i s s e and J. Ve r h o e f. 2002. Evaluation of the Etest ESBL and the BD Phoenix, VITEK 1, and VITEK 2 automated instruments for detection of extended-spectrum $-lactamases in multiresistant Escherichia coli and Klebsiella spp. J. Clin. Microbiol. 40: 3703 3711.

316 Stefaniuk E. et al. 4 M u r a k a m i K., W. M i n i m i d e, K. W a d a, E. N a k a m u r a, H. T e r a o k a and S. W a t a n a b e. 1991. Identification of methicillin resistant strains of Staphylococcus aureus by polymerase chain reaction. J. Clin. Microbiol. 29: 2240 2244. N a t i o n a l C o m m i t t e e f o r C l i n i c a l L a b o r a t o r y S t a n d a r d s. 2003a. Methods for Dilution Susceptibility Tests for Bacteria That Grow Aerobically; Approved standard Sixth Edition: M7-A6. NCCLS, Villanova, PA. N a t i o n a l C o m m i t t e e f o r C l i n i c a l L a b o r a t o r y S t a n d a r d s. 2003b. Performance Standards for Antimicrobial Disk Susceptibility Testing; Approved Standard Eighth Edition M2-A8. NCCLS, Villanova, PA. Pa³ucha A., B. Mikiewicz, W. Hryniewicz and M. Gniadkowski. 1999. Concurrent outbreaks of extendedspectrum beta-lactamase-producing organisms of the family Enterobacteriaceae in a Warsaw hospital. J. Antimicrob. Chemother. 44: 489 499. R u o f f K.L., R.A. W h i l e y and D. B e i g h t o n. 1999. Streptococcus, pp. 283 305. In: P.R. Murray, E.J. Baron, M.A. Pfaller, Tenover FC., Yolken RH. (eds): Manual of Clinical Microbiology, ed. 7. Washington, American Society for Microbiology. K a r l o v s k y J.A., M.K. W e a v e r, C. T h o r n s b e r r y, M.J. D o w z i c k y, M.E. J o n e s and D.F. S a h m. 2003. Comparison of four antimicrobial susceptibility testing methods to determine the in vitro activities of piperacillin and piperacillin-tazobactam against clinical isolates of Enterbacteriaceae and Pseudomonas aeruginosa. J. Clin. Microbiol. 41: 3339 3343. Stefaniuk E., A. Baraniak, M. Gniadkowski and W. Hryniewicz. 2003. The evaluation of the BD PHOENIX TM automated identification and susceptibility testing system in clinical microbiology laboratory practice. Eur. J. Clin. Microbiol. Infect. Dis. 22: 479 485.