COOPER POWER SERIES. S.T.A.R. PATHFINDER variable trip TPR faulted circuit indicator installation instructions. Fault indicators MN320003EN

Similar documents
COOPER POWER SERIES. S.T.A.R. Type ER faulted circuit indicator installation instructions. Fault Indicators MN320006EN

S Fault Indicators. S.T.A.R. Type CR Faulted Circuit Indicator Installation Instructions. Contents PRODUCT INFORMATION

SAFETY BURNDY HYPRESS TM OPERATING & MAINTENANCE INSTRUCTIONS Y750BH 2004 FCI USA INC.

Elite Outdoor Bark Control

FCI LT LM UNDERGROUND

Outdoor Bark Control

IEEE Std 592 Test Program using Current Cable Accessories and Installation Practices

OPERATING AND BASIC TRAINING GUIDE PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING

Operating Guide. PBC Rechargeable Bark Control Collar. Please read this entire guide before beginning.

Laurelview Dog Kennel

300 Yard Trainer GDT Product Manual

Product Manual. PBC Bark Collar. Please read this entire Product Manual before beginning.

SMARTKITTY SELFCLEANING LITTER BOX

Vibratory Tumbler OWNER S MANUAL

Getting Started. Device Overviews. Setting Up the Pro 550 System Before you can use the Pro 550 system, you must set up the devices.

400 Yard Trainer GDT Product Manual

Delta Smart. Owner s Manual

FAQ (Frequently Asked Questions)

INSTALLATION INSTRUCTIONS

NoBark 6. Operating Guide. Please read this entire guide before beginning

INSTALLATION INSTRUCTIONS

Table of Contents Operating Guide Training Guide

advanced bark control collar INSTRUCTION Manual

Fiber-Optic Accessories

Smart bark control collar BC-2. User manual

Basic Bark Control Collar

All rights reserved. Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of Garmin.

BARK CONTROL COLLAR Model NB-Pulse. User s guide

Elite Bark Control PBC operating and training guide. Big Dog Model Number. Little Dog Model Number

Model Number HBK '(W) x 5'(L) x 5'(H) laurelview. dog kennel assembly instructions. Please read this entire guide before assembly

advanced remote trainer INSTRUCTION Manual

INNOTEK. Spray Bark Control. Operating Guide. Please read this entire guide before beginning.

Product Manual. ZAL Simply Clean Automatic Litter Box. Please read this entire Product Manual before beginning.

Delta Upland XC. Owner s Manual. March 2015 Printed in Taiwan _0A

Delta Upland Owner s Manual

Pixie-7P. Battery Connector Pixie-7P Fuse* Motor. 2.2 Attaching the Motor Leads. 1.0 Features of the Pixie-7P: Pixie-7P Batt Motor

Programming and Installation Guide. PPA Microchip Cat Flap. Series. Please read this entire guide before beginning.

U xafaiagy10258nzw BLUING TANK STAND SYSTEM INSTRUCTIONS WARNING SETTING UP THE BLUING STANDS HEIGHT OF BURNERS GAS LINES FINAL SETUP #

Puppy Sales Contract

SUPER TRAINER EZT SERIES

OPERATING GUIDE PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING

PET DOOR. Deluxe Aluminium IMPORTANT! READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY AND KEEP FOR FUTURE REFERENCE. Product Codes: #1168, #1169, #1170

AquaReef 200. Instruction Manual

PetSafe Big Dog Spray Bark Control Collar

Part Number: CAT6+ UTP PVC PATCH CORDS CAT6+ Patch Cord, UTP, PVC

table of contents Personnel Protection Products SECTION L LS ECTION

Delta Upland Owner s Manual

PetSafe Deluxe Bark Control

PetSpy Advanced Dog Training System, Model M86N

By Dogtra Remote Controlled Dog Training Collars. Owner's Manual. Please read this manual thoroughly before operating the Dogtra EDGE training collar.

Product Manual 100, 300, 600 AND 900 YARD REMOTE TRAINERS LITE STANDARD ADD-A-DOG

INSTALLATION INSTRUCTIONS

Installation Instructions

Owner s Guide PCC-100 & PCC-200

HALE SECURITY PET DOOR CAT GUARDIAN patent pending

7300 SPT 7302 SPT 7800 SPT 7802 D.T. SYSTEMS, INC.

Part Number: CAT6+ UTP PVC PATCH CORDS CAT6+ Patch Cord, UTP, PVC

Upgrade KIT IV Operation Manual

Ultrasonic Bark Control Collar

SportHunter SD Operating Guide. Please read this entire guide before beginning

DURA PLASTIC PRODUCTS, INC.

PetSpy Premium Dog Training Collar, Models M919-1/M919-2

Your American Made Source

YEAR FOR MULTI-CAT HOUSEHOLDS. CustomerCare Line: LM580 LM680C LM980. AUTOMATIC Self-Cleaning Litter Box. USA/Canada , Option 1

Lioness Guidebook: Open Me to Get Started!

PET DOOR IMPORTANT! READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY AND KEEP FOR FUTURE REFERENCE.

V EN

ultrasmart receiver collar

INTRODUCTION PRODUCT FEATURES. Congratulations on your purchase of the Yapper Stopper Model YS500.

K9K-914 Anti Bark Collar User's Manual. Introduction:

FOR MULTI-CAT HOUSEHOLDS

W360 Multifunction Tabber System Operator Guide

The Other Door Steel Crate

Microchip Cat Flap. Instruction Manual Gebrauchsanweisung Hadleiding Notice D utilisation Brugervejledning

Elite Big Dog Spray Bark Control

EPA Est. No IL-001. Assurity and Elanco. EPA Reg. No

By Dogtra Remote Controlled Dog Training Collars. Owner's Manual. Please read this manual thoroughly before operating the Dogtra ARC training collar.

Product Manual. PDT Remote Spray Trainer. Please read this entire Product Manual before beginning.

Portable Washing Machine GPW-5

AT-215. Owner's Manual

WARNING KEEP OUT OF REACH OF CHILDREN DO NOT USE ON CATS. Code: pvasmmd

5140 Fence Free & 5132 Fence Free Deluxe Instruction Manual

4MONTHS FORDOGS MEDIUM DOG WARNING MEDIUM DOG LBS REPELS AND KILLS TICKS, FLEAS, & MOSOUITOS

Demi s Animal Rescue, Inc. Terms of Adoption (Dog) Animal s Name: Breed: Sex: Weight: Age: Microchip ID: Notes:

Bristle Discs and Brushes

Congratulations! Thank you for purchasing a ScoopFree. The Only Self-Cleaning Litter Box You Can Leave Alone For Weeks At A Time

Distributed by: Scotch-Brite Bristle Discs and Brushes. Patented abrasives. Safer operation and conformability in contoured areas.

SMART SCOOP SMARTSTART GUIDE FOR A FRESHER LITTER BOX

Please read this entire guide before beginning

User s Guide. High Performance Linear Products SLOU119

Woonsocket Education Department REQUEST FOR PROPOSAL. For. Copiers Multi Function Device Lease

Sold by:

Natural Gas.

LP-NSM(L) Series. Features. Product Dimensions. Small size of Fast tripping resettable circuit protection

KiwiSDR Quick Start Guide

Little Love Puppy Pal

Express Train Electronic Radio Dog Training Collar

Elite Little Dog Spray Bark Control

MODLINK MSDD Front Panel Interfaces

Quick Start ,3 Trouble Shooting ,5 Training

Transcription:

Fault indicators MN320003EN Effective March 2017 Supersedes July 2004 (S320-42-1) COOPER POWER SERIES S.T.A.R. PATHFINDER variable trip TPR faulted circuit indicator installation instructions Indicator boot Internal sleeve Pulling eye Led indicator

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. installation instructions MN320003EN March 2017 i

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY...i Safety for life...iii Safety information...iii Safety instructions...iii Product information.... 1 Installation procedures.... 1 For RTE 15, 25, and 35 kv loadbreak elbows and GE-Chardon 15 and 35 kv elbows...1 For all eaton cooper power series 200 A, 250 A and 400 A deadbreak elbows, elastimold 15, 25 and 35 kv (PCE) elbows and new design* blackburn 15 kv elbows...1 For old design* 15 and 25 kv blackburn elbows, elastimold 15, 25 and 35 kv (not PCE) elbows, joslyn 15 kv elbows and GE-Chardon 25 kv elbows...2 Operation.... 3 Installation Instructions for Remote Fiber Optic Display...4 Installation Instructions for Auxiliary Contacts...4 ii installation instructions MN320003EN March 2017

! SAFETY FOR LIFE Safety for life Eaton s Cooper Power series products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high-voltage lines and equipment and support our Safety For Life mission.! SAFETY FOR LIFE Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians, who are familiar with this equipment should install, operate and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as flash clothing, safety glasses, face shield, hard hat, rubber gloves, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result In death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with high voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and lowvoltage lines and equipment. WARNING Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. WARNING This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply may result in death, severe personal injury and equipment damage. WARNING Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install, or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. installation instructions MN320003EN March 2017 iii

CAUTION The Eaton Cooper Power series S.T.A.R. PATHFINDER Variable Trip TPR faulted circuit indicator is designed to be operated in accordance with normal safe operating procedures. These instructions are not intended to supersede or replace existing safety and operating procedures. Read all the instructions before installing the faulted circuit indicator. Faulted circuit indicators should be installed and serviced only by personnel familiar with good safety practice and the handling of high-voltage electrical equipment. Improper operation, handling, or maintenance can result in death, severe personal injury, and equipment damage. Product information The Eaton Cooper Power series S.T.A.R. PATHFINDER Variable Trip Test Point Reset (TPR) faulted circuit indicators (FCIs) are used on both 200 A separable connectors and 600 A terminators with voltage test points. They are easily installed with a shot-gun stick using the pulling eye. The FCI indicates the passage of fault current by a high-intensity LED display. When the system is re-energized, the indicator resets automatically. The FCI is weatherproof, submersible and meets or exceeds ANSI /IEEE 495-1986 Testing Guide. The status of the FCI will not change as a result of mechanical shock or vibration. The FCI uses a variable trip design, which senses load current and trips based on a rise in current above normal load. A minimum of 200 A (load current plus fault current) is required to trip the FCI. Indicator boot Figure 1. S.T.A.R. Type TPR faulted circuit indicator with internal sleeve Notee: Internal sleeve Pulling eye Led indicator At least 2.4 kv line-to-ground must be present to provide proper voltage sensing for the device. Installation procedures The TPR faulted circuit indicator can be installed on most manufacturers elbows. Instructions are included herein for RTE, Elastimold, Blackburn, Joslyn and GE-Chardon elbows. Where an adapter is required, a kit must be ordered separately. For RTE 15, 25, and 35 kv loadbreak elbows and GE-Chardon 15 and 35 kv elbows 1. The FCI can be installed on live elbows. As an alternative, de-energize the circuit and elbow terminator and ground the terminator according to approved procedures. 2. Remove the cap from the elbow test point using a hotstick. 3. Be sure the test point area is clean and dry. 4. Discard the internal sleeve. 5. Lightly lubricate the inside of the indicator boot using a silicone lubricant. A. If fiber optic cable remote is to be used with the FCI, snap the fiber optic fitting onto the LED indicator display on the housing of the FCI, prior to attaching the FCI to the hotstick (see Figure 6). 6. Attach the pulling eye of the indicator to the hotstick. 7. Using steady pressure, push the boot over the test point while rotating the boot. 8. Align the pulling eye on the indicator with the elbow pulling eye. (See Figures 3 and 4) For all Eaton Cooper Power series 200 A, 250 A and 400 A deadbreak elbows, elastimold 15, 25 and 35 kv (PCE) elbows and new design* blackburn 15 kv elbows 1. The FCI can be installed on live Elastimold (PCE) or new design Blackburn elbows. As an alternative, de-energize the circuit and elbow terminator and ground the terminator according to approved procedures. 2. Remove the cap from the elbow test point using a hotstick. 3. Be sure the test point area is clean and dry. 4. Insert the internal sleeve into the indicator boot. (See Figure 2) 5. Lightly lubricate the inside of the internal sleeve using a silicone lubricant. A. If fiber optic cable remote is to be used with the FCI, snap the fiber optic fitting onto the LED indicator display on the housing of the FCI, prior to attaching the FCI to the hotstick (see Figure 5). These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for the user s purpose, contact your Eaton representative. 1 installation instructions MN320003EN March 2017

6. Attach the pulling eye of the indicator to the hotstick. 7. Using steady pressure, push the boot over the test point while rotating the boot. 8. Align the pulling eye on the indicator with the elbow pulling eye. (See Figures 3 and 4) Table 1. Adapter screw and thread sizes** Elbow manufacturer Screw & thread size 15 and 25 kv Blackburn old design 3/8 in. 24 15 kv Joslyn, Elastimold 15, 25 and 35 kv (Not PCE) 5/16 in. 24 25 kv GE-Chardon 1/4 in. 20 ** Consult your Eaton representative for other available screw sizes. 5. Be sure the test point is clean and dry. 6. Using the 7/64 inch hex wrench provided, screw the adapter and plastic washer into the test point using the hotstick with tool holder. 7. Discard the internal sleeve. 8. Lightly lubricate the inside of the indicator boot using a silicone lubricant. A. If fiber optic cable remote is to be used with the FCI, snap the fiber optic fitting onto the LED indicator display on the housing of the FCI, prior to attaching the FCI to the hotstick (see Figure 6). 9. Attach the pulling eye of the indicator to the hotstick. Figure 2. Internal sleeve inserted into indicator boot For old design* 15 and 25 kv blackburn elbows, elastimold 15, 25 and 35 kv (not PCE) elbows, joslyn 15 kv elbows and GE-Chardon 25 kv elbows 1. A separate adapter (Catalog # STAK) is required for the old design 15 and 25 kv Blackburn, Elastimold 15, 25 and 35 kv (not PCE), Joslyn 15 kv and GE-Chardon 25 kv elbows. It is not included with the FCI and must be ordered separately. Because an adapter is needed, a slotted screwdriver and hex head driver mounted on a hotstick with tool holder is also required. 10. Using steady pressure, push the boot over the test point while rotating the boot. 11. Align the pulling eye on the indicator with the elbow pulling eye. (See Figures 3 and 4). 2. De-energize the circuit and elbow terminator and ground the terminator according to approved procedures. 3. Remove the cap from the elbow test point. 4. Remove and discard the screw and steel washer from the center of the test point. From the referenced adapter kit, select the proper adapter screw and thread size from Table 1. * Blackburn completed an elbow design change around July, 1992. Any Blackburn elbow sold and/or shipped prior to July, 1992 could be of either the old or new design. After determining the design, follow the appropriate instructions for installing the FCI. Figure 3. Correct methods of aligning Loadbreak elbow with fault indicator installation instructions MN320003EN March 2017 2

Operation Figure 4. Incorrect methods of aligning Loadbreak elbow with fault indicator Once installed on the test point, the manual testing/reset tool should be used to initialize the FCI and check for proper operation (see Figure 5).The indicator is then ready for use. When a fault occurs, the LED display will flash for a period of 4 hours. The unit may be manually reset prior to the 4 hour time delay following the fault, using the manual testing/reset tool (catalog SMRT). The unit will reset automatically if normal system voltage is restored. If the unit is not reset manually and system voltage has not been restored, the Battery Life Optimization Circuit (BLOC) operates after the 4 hour time delay, turning off the LED display to conserve battery life. The unit retains a log of the fault until interrogated using the manual testing/reset tool, or until normal system power has been restored. To interrogate the FCI following the 4 hour time delay, but prior to restoration of normal system power, touch the manual testing/reset tool to the R on the lower right side of the housing, as shown in Figure 4. If the FCI recorded a fault prior to the operation of the BLOC feature, a series of short, rapid flashes will be seen on the LED display for approximately 5 seconds. If no fault was detected by the FCI prior to loss of system power, 3 longer flashes will be seen on the LED display. After interrogating the FCI, it is then reset and ready to detect the next fault occurence. Fiber optic fitting (To led display) Mounting Wall Bushing 21/64 DIA. Hole Figure 5. Interrogating the Variable Trip TPR faulted circuit indicator Notee: If the Variable Trip TPR FCI is removed while indicating a fault, or in the energy saving (BLOC) mode, the device will only reset if installed on a system with the same line voltage at which the device had been previously installed, or, if manually reset using the testing/reset tool. It is recommended that he unit be reset manually using the testing/reset tool, to initialize the unit, after being installed. Outer display fitting Figure 6. Remote fiber optic cable display installation diagram 3 installation instructions MN320003EN March 2017

Installation instructions for remote fiber optic display WARNING The Eaton Cooper Power series S.T.A.R. PATHFINDER Variable Trip TPR Faulted Circuit Indicator with remote display and/or auxiliary contact outputs are designed for installation at Ground Potential Only. Remote indicators and auxiliary contacts are not insulated for high voltage application. If high voltage is applied across the fault indicator, flashover may occur, possibly resulting in death, severe personal injury, and equipment damage. 1. Drill one 21/64 inch diameter hole as shown in Figure 5. Hole rim may need to be treated for corrosion resistance. Consult enclosure manufacturer for recommendation. 2. Ensure that the fiber optic fitting has been snapped onto the LED display of the FCI housing. If this was not done prior to installing the FCI on a live elbow, use gloved hands to snap the fiber optic fitting of the remote display cable onto the LED display of the FCI. 3. Insert the outer fitting through the 21/64 inch diameter hole with the threads extending through the hole in the enclosure. 4. Insert the end of the fiber optic cable into the outer display fitting. 5. Thread the bushing at the end of the fiber optic cable, onto the outer fitting. 6. Adjust the display to the desired alignment and tighten the nut to pull the outer fitting against the front of the enclosure. Tighten sufficiently to prevent removal of the outer fitting from outside the cabinet, but do not overtighten the nuts. Eaton s Cooper Power series S.T.A.R. PATHFINDER Variable Trip Test Point Reset FCIs are available with auxiliary contacts as an option. The contact provides a means to monitor the status of the FCI remotely. The contact mirrors the status of the faulted circuit indicator. If the FCI has sensed a fault, the dry contacts will latch closed until the FCI is reset manually or until normal system power is restored, following the fault. If the FCI has been reset, the dry contacts will latch in the open position. A simple control diagram of the contacts is shown in Figure 7. When the auxiliary contact option is included with the FCI the following applies: the auxiliary contacts provide a relay closure when the FCI is in the faulted position. The contacts are normally open, and the FCI comes supplied with a pair of 6 foot conductor leads. The contacts will open when the FCI is reset with the appropriate system voltage of at least 2.4 kv. The auxiliary contacts are rated as follows: Red 1 A 30 VDC 0.5 A 125 VAC 0.3 A 110 VAC Black N.O. In the reset position Figure 7. Control drawing of auxiliary contacts Installation instructions for auxiliary contacts WARNING The Auxiliary Contact option is intended solely for use with faulted circuit indicators being installed on deadfront design equipment. DO NOT USE the auxiliary contact feature on fault indicators being applied to overhead conductors or live-front equipment. Exposed ends of the auxiliary contact cable may contact bare conductors or other energized equipment, and may result in electrocution hazard. The faulted circuit indicators should be installed and serviced only by personnel familiar with good safety practice and the handling of high-voltage electrical equipment. installation instructions MN320003EN March 2017 4

This page intentionally left blank. 5 installation instructions MN320003EN March 2017

This page intentionally left blank. installation instructions MN320003EN March 2017 6

This page intentionally left blank. 7 installation instructions MN320003EN March 2017

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No. MN320003EN March 2017 #5000050837 Rev. 2 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.