SIZING THE DAM BUSTER RAINHEAD

Similar documents
Design Guide. You can relax with a INSTALLATION QUALITY,CERTIFIED QTANK POLY RAINWATER TANKS. qtank.com.au

INSTALLATION GUIDE. Pot filler faucets. PF 3100 Ambient Series. PF 3200 Logik Series. PF 3300 Farm House Series

You will need few things to build up your aquarium but make sure everything is of a good quality.

INSTALLATION INSTRUCTIONS

Z Purlins C Sections Eaves Beams

Tool holders from Sandvik Coromant. Hydro-Grip. Assortment of high precision chucks

S Fault Indicators. S.T.A.R. Type CR Faulted Circuit Indicator Installation Instructions. Contents PRODUCT INFORMATION

U xafaiagy10258nzw BLUING TANK STAND SYSTEM INSTRUCTIONS WARNING SETTING UP THE BLUING STANDS HEIGHT OF BURNERS GAS LINES FINAL SETUP #

Automatic chain feeding

PET DOOR. Deluxe Aluminium IMPORTANT! READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY AND KEEP FOR FUTURE REFERENCE. Product Codes: #1168, #1169, #1170

MGG Radio Controlled Hidden Fencing System for Dogs. Operator s Manual for Model no: HT-023

A GUIDE TO BUILDING FERAL CAT SHELTERS. brought to you by

MGG Radio Controlled Hidden Fencing System for Dogs. Operator s Manual for Model no s: 023 and 023B

Tubeclip range of clamps and fittings Ideally suited for Agriculture, Theatre, Shop Fitting, Horticulture and many other applications.

HALE SECURITY PET DOOR CAT GUARDIAN patent pending

AquaReef 200. Instruction Manual

AQUARIUM CATALOGUE ISSUE 1. Friendly Fish Aquatics. We do things differently Fri. Fqwwsdsd. Friendly Fish Aquatics

AGILITY OBSTACLE GUIDELINES

DESIGNING YOUR RAINWATER CATCHMENT AND STORAGE SYSTEM

ReproMatic & FluxxBreeder

Meter Risers, Fittings & PE Pipe for Underground Gas Applications

Programming and Installation Guide. PPA Microchip Cat Flap. Series. Please read this entire guide before beginning.

BARK CONTROL COLLAR Model NB-Pulse. User s guide

Manufacturing Programme/Load Tables. FischerKASSETTE. * An enterprise of Tata Steel

HEALTHY TONGA TOURISM A GUIDE TO CONTROLLING MOSQUITO-BORNE DISEASES FOR TOURIST ACCOMMODATION BUSINESSES IN TONGA

COOPER POWER SERIES. S.T.A.R. PATHFINDER variable trip TPR faulted circuit indicator installation instructions. Fault indicators MN320003EN

CAT UNDERCARRIAGE SELECTION GUIDE. Helping you select the right undercarriage

DIGITUS Network Cabinet Unique Series, 600, 800 mm width - 600, 800, 1000, 1200 mm depth

BUYING GUIDE ALGOT. Storage across the home. DESIGN Francis Cayouette

INSTALLATION INSTRUCTIONS

Blue Malawi Operation Manual GB

XL³ 800 IP 55metal distribution cabinets, freestanding enclosures and cable compartments

INSTALLATION INSTRUCTIONS

Air Receivers TECHNOLOGY YOU CAN TRUST

Minimum Requirements for the Keeping of Domestic Animals. 11 Cattle. Animal Protection Ordinance

XL³ 400 class II insulated distribution cabinets and cable compartments

Poultry Watering Systems Catalogue

AUGERMATIC. The feeding system for successful poultry growing

Complete Range of Watering Systems for Breeders & Pullets

RELIA-FLOW and STEADI-FLOW Nipple Drinking Systems and Accessories

KiwiSDR Quick Start Guide

PLAIN MILLING CUTTERS

PLEASANT HILL CEMETERY IMPROVEMENT ASSOCIATION

Complete Solutions for BROILER BREEDERS

Bird Weighing. Precision weighing systems for all types of poultry mobile or fixed installation

Wall Mounted Cat Tree Instruction Manual

SOP: Blood Collection in Swine


Design. 3PF Series Triple-Screw Pumps. Manual. MAAG E-01

Regulations not related to Grading or Heights all effective 1 January 2019

PIGEON MAGNET INSTRUCTION MANUAL

Upgrade KIT IV Operation Manual

Getting Started. Device Overviews. Setting Up the Pro 550 System Before you can use the Pro 550 system, you must set up the devices.

King Fahd University of Petroleum & Minerals College of Industrial Management

FCI Molded Products Inc. VOL 1.0

ReproMatic & FluxxBreeder

Contents. Introduction...Page 3. Safety Instructions...Page 4. Before You Commence Installation...Page 5. Measuring Up...Page 6

SOP: Blood Collection in the Horse

Interrow cultivator. Hatzenbichler interrow cultivator programm AUSTRIAN AGRO TECHNIK

Breeder Package. Our Experience. Your Success.

ASSEMBLY & INSTRUCTION MANUAL

HEAVILY GALVANISED FOR EXTENDED LIFE

AugerMatic & TruPan. Feeding system for rearing and growing turkeys

Glassbrook Cemetery lots: Corner of Harrisburg and Glassbrook Road

Distributed by: Scotch-Brite Bristle Discs and Brushes. Patented abrasives. Safer operation and conformability in contoured areas.

INTERNATIONAL STANDARD FOR FCI PIGEON FOOTRINGS

PET DOOR IMPORTANT! READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY AND KEEP FOR FUTURE REFERENCE.

NATURA CAGE-FREE. Modern aviary system for barn and free range egg production

Live animal regulations. Kennel sizing chart for dogs and cats

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial

Laurelview Dog Kennel

Instruction Manual. 6. Connectors. Latest news and tips can be taken from Be flapscinated.

Election Commission of India. Training on Use of Electronic Voting Machine

Bristle Discs and Brushes

Code of Practice for the Operation of Greyhound Establishments

United States Department of Agriculture Animal and Plant Health Inspection Service. Inspection Report

Pixie-7P. Battery Connector Pixie-7P Fuse* Motor. 2.2 Attaching the Motor Leads. 1.0 Features of the Pixie-7P: Pixie-7P Batt Motor

TRUCK PUMPS HYDRAULIC GEAR PUMPS

Hillside Cultivator Co. LLC Prices and Parts

DOGSLIFE BEDS. wholesale products list 2018 SLEEPING I. 19 Osprey Drive, Jacobs Well. Qld. 4208

T H E UNIQUE FEN C ING S Y S TEM

FREQUENTLY ASKED QUESTIONS Pet Owners

Quick Setup Guide Model 5134G

Portable Washing Machine GPW-5

Smart bark control collar BC-2. User manual

National Unit Specification: general information. UNIT Animal Care: Breeding (SCQF level 5) CODE F6SS 11 SUMMARY OUTCOMES RECOMMENDED ENTRY

Fiber-Optic Accessories

Poultry Watering Systems Catalogue

SWGDOG SC 9 - HUMAN SCENT DOGS Avalanche Search

Catalogue. cable protectors and safety products

Stainless One-touch Fittings. Applicable Tubing. Tubing material Tubing O.D. Note 1) Soft nylon tubing is not compatible with water.

Lifting points for CLT. a practical guide

N-2 EDS Factory Sealed and EFS Tumbler Switches: Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

Drinking Systems for Breeders & Pullets

INTRODUCTION PRODUCT FEATURES. Congratulations on your purchase of the Yapper Stopper Model YS500.

Breeder Package. Our Experience. Your Success. Count on Chore-Time for experience, reliability, performance and confidence.

Part Number: CAT6+ UTP PVC PATCH CORDS CAT6+ Patch Cord, UTP, PVC

OWNER S MANUAL For large-size wheelchair ( lbs)

Happy hens. Teacher guidance - 1. Introduction. Project overview

Electromagnetic flowmeters. dg: NEW. Sensors MUT 2200 EL / MUT 2500 EL DS100-4-ENG 1/14

Transcription:

1 P a g e SIZING THE DAM BUSTER RAINHEAD 1 Size the catchment area by referring to the Dam Buster Design Guide. Follow Step 1, Step 2 and Step 3 to determine the roof catchment area design flow rate in L/sec for a Dam Buster rainhead and downpipe combination. The Dam Buster Design Guide, including the Dam Buster Rainhead Design Table, has been developed by civil and hydraulic engineers to meet the requirements of AS/NZS 3500.3 NOTE 1A: Dam Buster rainheads can be used in all geographical locations within Australia. However, the catchment area which can be compliantly serviced by an individual Dam Buster rainhead decreases in geographical locations with higher rainfall ARI. This is because each Dam Buster rainhead is sized for a maximum design flow rate in L/sec. The maximum overflow capacity of the rainhead must be equal to or greater than this design flow rate. NOTE 1B: All Dam Buster rainheads have engineer certified overflow capacity equal to or exceeding 16L/sec which is the maximum design flow referenced by Australian Standards. NOTE 1C: The ARI is based on the maximum rainfall intensity in mm/hour, which occurs over a 5 minute period. The technical term is 100I 5, where 100I is the return period in years, and 5 minutes is the duration of the heavy rainstorm. Capital City ARIs are included in the Dam Buster Design Guide. If you are in a regional or outer metropolitan location, you will need to refer to AS/NZS 3500.3 (Appendix E rainfall charts) to determine the ARI for the installation location. 2 After calculating the catchment area and the design flow rate in L/sec, you will also need to consider box gutter sole width and shape. For Lear-type box gutters, measure the sole width of the gutter section itself, not including the triangular area of the lear. NOTE 2A: If the box gutter width falls between any of the Dam Buster rainhead sizes you will need to select the larger Dam Buster rainhead size. Dam Buster rainheads can be adapted to any box gutter width up to 600mm with the use of the provided optional Back Plate component (which is supplied with every Dam Buster Rainhead). E.g. for a 350mm sole width box gutter, select a Dam Buster 400 which can then be customised to suit by using the Back Plate component (see Dam Buster Installation Instruction no: 3). NOTE 2B: In Australia, the minimum compliant sole width of a box gutter for a domestic building is 200mm and for a commercial building is 300mm. Side walls of a box gutter are dependent on the discharge method (i.e. rainhead or sump) and must also be sized according to the catchment area design flow rate in L/sec.

INSTALLATION INSTRUCTIONS FOR THE DAM BUSTER RAINHEAD IMPORTANT NOTE: Before proceeding you must always correctly size the Dam Buster rainhead to suit the design flow rate in L/sec for the catchment area. Refer to Sizing the Dam Buster Rainhead instructions and also the Dam Buster Design Guide for guidance. YOU WILL NEED: - 3.2mm (1/8 th inch) diam 3.2mm (1/8 th inch) grip sealed appropriately corrosion resistant pop rivets 4.1 - Hand riveter - 3.2mm (1/8 th inch) drill bit and small battery drill - Silicone gun and 1 x tube of Roof & Gutter Silicone (colour matched) - Left and right hand snips - Downpipe pop to suit sizing requirement - 2 or 4 (depending on size of the Dam Buster) x appropriately corrosion resistant wall fixings or screws (maximum 5.5mm in size) - Spirit Level - Clean rags - Set Square - Pencil 2 P a g e

See Diagram A showing section of the installed Dam Buster rainhead and box gutter for overview of installation. 1. Where the box gutter exits the wall of the building, the end of the box gutter should be cut to protrude precisely 25mm from the outside cladding face of the building. Measure precisely 25mm and neatly cut a small V shape in the corners at the base of each side of the box gutter using left and right handed snips. DO NOT bend this cut tab of the sole of the box gutter downwards yet. 2. Dry test the Dam Buster rainhead to ensure that the rear seal slides easily under the sole of the box gutter and that the Dam Buster rainhead fits snugly to the wall of the building and the box gutter. 3. If a box gutter size does not exactly match the proprietary width of the Dam Buster rainhead, then the optional Back Plate component (supplied) will need to be fitted to the Dam Buster rainhead. This will require the rivets on the rear of the Dam Buster rainhead to be drilled out so that the Back Plate component can be inserted and then re-riveted into position in place of or alternatively used in conjunction with the existing box gutter attachment component. The Back Plate component can then be cut to suit the exact size of the box gutter and fashioned to create its own seal against the side walls of the box gutter. The correct rivet size for re-installation of the back plate is a sealed 3.2mm (1/8 th inch) diam 3.2mm (1/8 th inch) grip rivet. 4. Once the downpipe size has been selected (based on the Dam Buster Rainhead Design Table in the Dam Buster Design Guide), neatly cut and rivet a downpipe pop into the base of the Dam Buster rainhead to suit the downpipe size, shape and position. Use colour-matched Roof & Gutter Silicone to seal the downpipe pop. 5. Carefully and thoroughly apply colour-matched Roof & Gutter Silicone to seal all of the seams and rivet fixings on the inside of the Dam Buster rainhead, including the open seam on both sides which is directly beneath the main overflow weir, facing the external facade. Note: Dam Buster rainheads are not pre-siliconed as this enables customisation with the optional back-plate if required. Therefore careful sealing must be carried out by the installing roof plumber. 3 P a g e

6. Apply 2 x generous beads of Roof & Gutter Silicone fully across the rear of the Dam Buster Rainhead on top of the base of the box gutter seal and also down the internal sides of the box gutter seal. Optionally, silicone can also be applied on the outside of the rear of the Dam Buster rainhead and box gutter seal. The silicone will act as a seal to the area around the outside of the box gutter wall junction when the Dam Buster rainhead is pressed against the wall of the building (much like a cover plate). See Diagram B showing connection of Dam Buster rainhead attachment to box gutter. 7. Carefully insert the Dam Buster Rainhead under the box gutter. IMPORTANT: The box gutter fits directly into the Dam Buster Rainhead. Do NOT attempt to fit the Dam Buster Rainhead into the box gutter. 8. Drill no less than 3 x 3.2mm (1/8 th inch) diameter staggered rivet holes in to each of the side walls of the box gutter, also penetrating the seal on the Dam Buster Rainhead. Insert and fix no less than 3 x appropriately corrosion resistant pop rivets on each side wall. Drill and pop rivet the sole of the box gutter to fix and seal to the gutter receptor, as required. Carefully seal each rivet with Roof & Gutter silicone and wipe away any metal swarf from within the box gutter. 9. Fix the Dam Buster Rainhead to the wall via the external lugs on both sides ensuring that the Dam Buster rainhead is installed level with use of a spirit level. Use appropriately corrosion resistant screws or fixings. 10. If using the optional back plate installation method, also now ensure that the box gutter is fully sealed to the rainhead using sufficient Roof & Gutter Silicone. 4 P a g e

11. Now turn down the 25mm overhang on the sole of the box gutter into the Dam Buster rainhead to an angle of approximately 45 degrees (min). 12. Fit and fix the downpipe into the downpipe pop with appropriately corrosion resistant rivets. Ensure downpipe is appropriately saddled along its entire length in compliance with the requirements of HB39. 13. Advise Property Owners of the requirement of Australian Standards (AS/NZS 3500.3; Section 3.3.1 and Paragraph N5, Appendix N) for the regular maintenance of the roof drainage system (i.e. cleaning of any accumulated debris from the box gutter and rainhead on a regular basis). NOTE: It is the plumber s responsibility to ensure all works associated with the box gutter and Dam Buster rainhead are carried out in accordance with the current versions of AS/NZS 3500.3 and HB39 and HB114. www.dambuster.com.au 5 P a g e

6 P a g e DIAGRAM A

7 P a g e DIAGRAM B